1*** Settings *** 2Documentation Update the BMC code on a target BMC. 3... Execution Method: 4... python -m robot -v OPENBMC_HOST:<hostname> 5... -v IMAGE_FILE_PATH:<path/*.tar> bmc_code_update.robot 6 7Library ../../lib/code_update_utils.py 8Library ../../lib/gen_robot_keyword.py 9Variables ../../data/variables.py 10Resource ../../lib/utils.robot 11Resource ../../lib/boot_utils.robot 12Resource code_update_utils.robot 13Resource ../../lib/code_update_utils.robot 14Resource ../../lib/openbmc_ffdc.robot 15Resource ../../lib/dump_utils.robot 16Resource ../../lib/certificate_utils.robot 17 18Suite Setup Suite Setup Execution 19 20Test Teardown Test Teardown Execution 21 22# Force the test to timedout to prevent test hanging. 23Test Timeout 30 minutes 24 25Force Tags BMC_Code_Update 26 27*** Variables *** 28 29${QUIET} ${1} 30${IMAGE_FILE_PATH} ${EMPTY} 31${ALTERNATE_IMAGE_FILE_PATH} ${EMPTY} 32${SKIP_UPDATE_IF_ACTIVE} false 33${dump_id} ${EMPTY} 34${running_persistence_test} ${FALSE} 35${test_errlog_text} AutoTestSimple 36 37*** Test Cases *** 38 39Test Basic BMC Performance Before BMC Code Update 40 [Documentation] Check performance of memory, CPU & file system of BMC. 41 [Tags] Test_Basic_BMC_Performance_Before_BMC_Code_Update 42 43 Open Connection And Log In 44 Check BMC Performance 45 46Prepare Persistent Data 47 [Documentation] Set data that should persist across the code update. 48 [Tags] Prepare_Persistent_Data 49 50 # Install the debug tarball. 51 BMC Execute Command rm -rf /tmp/tarball 52 Install Debug Tarball On BMC tarball_file_path=${DEBUG_TARBALL_PATH} 53 54 # Create a dummy error log and dump. 55 BMC Execute Command /tmp/tarball/bin/logging-test -c ${test_errlog_text} 56 ${dump_id}= Create User Initiated Dump 57 Check Dump Existence ${dump_id} 58 Set Suite Variable ${dump_id} 59 60 # Set persistent settings. 61 ${autoreboot_dict}= Create Dictionary data=${0} 62 Write Attribute ${CONTROL_HOST_URI}auto_reboot AutoReboot 63 ... data=${autoreboot_dict} 64 ${onetime_dict}= Create Dictionary data=${0} 65 Write Attribute ${CONTROL_HOST_URI}boot/one_time Enabled 66 ... data=${onetime_dict} 67 68 # Let the remaining test cases know we are doing a persistence test so we 69 # do not delete logs. 70 Set Suite Variable ${running_persistence_test} ${TRUE} 71 72 73REST BMC Code Update 74 [Documentation] Do a BMC code update by uploading image on BMC via REST. 75 [Tags] REST_BMC_Code_Update 76 [Teardown] REST BMC Code Update Teardown 77 78 Run Keyword And Ignore Error List Installed Images BMC 79 Run Keyword And Ignore Error Set ApplyTime policy=OnReset 80 81 ${image_version}= Get Version Tar ${IMAGE_FILE_PATH} 82 ${bmc_release_info}= Get BMC Release Info 83 ${functional_version}= Set Variable ${bmc_release_info['version_id']} 84 Rprint Vars image_version functional_version 85 86 # Check if the existing firmware is functional. 87 Pass Execution If '${functional_version}' == '${image_version}' 88 ... The existing ${image_version} firmware is already functional. 89 90 Run Keyword And Ignore Error Delete Only BMC Image 91 92 Upload And Activate Image ${IMAGE_FILE_PATH} 93 ... skip_if_active=${SKIP_UPDATE_IF_ACTIVE} 94 OBMC Reboot (off) 95 Verify Running BMC Image ${IMAGE_FILE_PATH} 96 BMC Execute Command cd /etc ; cat host.conf hosts hostname print_out=1 97 98 99Verify Error Log Persistency 100 [Documentation] Check that the error log is still present after a 101 ... code update. 102 [Tags] Verify_Error_Log_Persistency 103 104 ${error_log_paths}= Read Properties ${BMC_LOGGING_ENTRY}list 105 Log To Console ${error_log_paths} 106 ${test_error_message}= Read Attribute @{error_log_paths}[-1] Message 107 Should Be Equal ${test_error_message} 108 ... example.xyz.openbmc_project.Example.Elog.${test_errlog_text} 109 Delete Error Log Entry @{error_log_paths}[-1] 110 111 112Verify BMC Dump Persistency 113 [Documentation] Check that the BMC dump present after a code update. 114 [Tags] Verify_BMC_Dump_Persistency 115 [Teardown] Set Suite Variable ${running_persistence_test} ${FALSE} 116 117 Check Dump Existence ${dump_id} 118 Delete BMC Dump ${dump_id} 119 120 121Verify Settings Persistency 122 [Documentation] Verify that the settings from 'Prepare Persistent Data' 123 ... are still set correctly after the code update. 124 [Tags] Verify_Settings_Persistency 125 126 ${autoreboot_enabled}= Read Attribute ${CONTROL_HOST_URI}auto_reboot 127 ... AutoReboot 128 Should Be Equal ${autoreboot_enabled} ${0} 129 ${onetime_enabled}= Read Attribute ${CONTROL_HOST_URI}boot/one_time 130 ... Enabled 131 Should Be Equal ${onetime_enabled} ${0} 132 133 # Set values back to their defaults 134 ${autoreboot_dict}= Create Dictionary data=${1} 135 Write Attribute ${CONTROL_HOST_URI}auto_reboot AutoReboot 136 ... data=${autoreboot_dict} 137 ${onetime_dict}= Create Dictionary data=${1} 138 Write Attribute ${CONTROL_HOST_URI}boot/one_time Enabled 139 ... data=${onetime_dict} 140 141 142Upload And Activate Multiple BMC Images 143 [Documentation] Upload another BMC image and verify that its state is 144 ... different from all others. 145 [Tags] Upload_And_Activate_Multiple_BMC_Images 146 [Template] Activate Image And Verify No Duplicate Priorities 147 [Setup] Upload And Activate Multiple BMC Images Setup 148 149 # Image File Path Image Purpose 150 ${ALTERNATE_IMAGE_FILE_PATH} ${VERSION_PURPOSE_BMC} 151 152 153BMC Set Priority To Invalid Values 154 [Documentation] Attempt to set the priority of an image to an invalid 155 ... value and expect an error. 156 [Tags] BMC_Set_Priority_To_Invalid_Values 157 [Template] Set Priority To Invalid Value And Expect Error 158 159 # Version Type Priority 160 ${VERSION_PURPOSE_BMC} ${-1} 161 ${VERSION_PURPOSE_BMC} ${256} 162 163 164Delete BMC Image 165 [Documentation] Delete a BMC image from the BMC flash chip. 166 [Tags] Delete_BMC_Image 167 168 ${software_object}= Get Non Running BMC Software Object 169 Delete Image And Verify ${software_object} ${VERSION_PURPOSE_BMC} 170 171 172BMC Image Priority Attribute Test 173 [Documentation] Set "Priority" attribute. 174 [Tags] BMC_Image_Priority_Attribute_Test 175 [Template] Temporarily Set BMC Attribute 176 177 # Property Value 178 Priority ${False} 179 Priority ${True} 180 Priority ${0} 181 Priority ${1} 182 Priority ${127} 183 Priority ${255} 184 185 186Delete All Non Running BMC Images 187 [Documentation] Delete all non running BMC images. 188 [Tags] Delete_All_Non_Running_BMC_Images 189 190 ${version_id}= Upload And Activate Image ${ALTERNATE_IMAGE_FILE_PATH} 191 ... skip_if_active=true 192 Delete All Non Running BMC Images 193 194 ${software_ids}= Get Software Objects Id 195 ... version_type=${VERSION_PURPOSE_BMC} 196 Should Not Contain ${software_ids} ${version_id} 197 198 199Test Certificate Persistency After BMC Code Update 200 [Documentation] Test certificate persistency after BMC update. 201 [Tags] Test_Certificate_Persistency_After_BMC_Code_Update 202 203 # Create certificate sub-directory in current working directory. 204 Create Directory certificate_dir 205 OperatingSystem.Directory Should Exist ${EXECDIR}${/}certificate_dir 206 207 ${cert_file_path}= Generate Certificate File Via Openssl 208 ... Valid Certificate Valid Privatekey 209 ${file_data}= OperatingSystem.Get Binary File ${cert_file_path} 210 ${cert_file_content}= OperatingSystem.Get File ${cert_file_path} 211 212 Redfish.Login 213 ${cert_id}= Install Certificate File On BMC ${REDFISH_CA_CERTIFICATE_URI} ok data=${file_data} 214 Logging Installed certificate id: ${cert_id} 215 216 # Adding delay after certificate installation. 217 Sleep 30s 218 219 ${bmc_cert_content}= redfish_utils.Get Attribute 220 ... /redfish/v1/Managers/bmc/Truststore/Certificates/${cert_id} CertificateString 221 Should Contain ${cert_file_content} ${bmc_cert_content} 222 223 Upload And Activate Image ${IMAGE_FILE_PATH} 224 ... skip_if_active=${SKIP_UPDATE_IF_ACTIVE} 225 OBMC Reboot (off) 226 Verify Running BMC Image ${IMAGE_FILE_PATH} 227 228 Redfish.Login 229 ${bmc_cert_content}= redfish_utils.Get Attribute 230 ... ${REDFISH_CA_CERTIFICATE_URI}/${cert_id} CertificateString 231 Should Contain ${cert_file_content} ${bmc_cert_content} 232 233 Redfish.Logout 234 235 236Test Basic BMC Performance After Code Update 237 [Documentation] Check performance of memory, CPU & file system of BMC. 238 [Tags] Test_Basic_BMC_Performance_After_Code_Update 239 240 Open Connection And Log In 241 Check BMC Performance 242 243 244*** Keywords *** 245 246Temporarily Set BMC Attribute 247 [Documentation] Update the BMC attribute value. 248 [Arguments] ${attribute_name} ${attribute_value} 249 250 # Description of argument(s): 251 # attribute_name BMC software attribute name (e.g. "Priority"). 252 # attribute_value Value to be written. 253 254 ${image_ids}= Get Software Objects ${VERSION_PURPOSE_BMC} 255 ${init_bmc_properties}= Get Host Software Property ${image_ids[0]} 256 ${initial_priority}= Set Variable ${init_bmc_properties["Priority"]} 257 258 Set Host Software Property ${image_ids[0]} ${attribute_name} 259 ... ${attribute_value} 260 261 ${cur_bmc_properties}= Get Host Software Property ${image_ids[0]} 262 Should Be Equal As Integers ${cur_bmc_properties["Priority"]} 263 ... ${attribute_value} 264 265 # Revert to to initial value. 266 Set Host Software Property 267 ... ${image_ids[0]} ${attribute_name} ${initial_priority} 268 269 270Upload And Activate Multiple BMC Images Setup 271 [Documentation] Check that the ALTERNATE_FILE_PATH variable is set. 272 273 Should Not Be Empty ${ALTERNATE_IMAGE_FILE_PATH} 274 275 276Delete Only BMC Image 277 [Documentation] Delete a BMC image from the BMC flash chip. 278 279 ${software_object}= Get Non Running BMC Software Object 280 Delete Image And Verify ${software_object} ${VERSION_PURPOSE_BMC} 281 282 283REST BMC Code Update Teardown 284 [Documentation] Do code update test teardown. 285 286 FFDC On Test Case Fail 287 Run Keyword If Test Failed Fatal Error msg=Code update failed. 288 289 290Suite Setup Execution 291 [Documentation] Do code update test case setup. 292 # - Clean up all existing BMC dumps. 293 294 Run Key Delete All Dumps ignore=1 295 Run Keyword And Ignore Error Smart Power Off 296 297Test Teardown Execution 298 [Documentation] Do code update test case teardown. 299 # 1. Collect FFDC if test case failed. 300 # 2. Collect FFDC if test PASS but error log exists. 301 302 # Don't delete our logs if we want to persist them for tests. 303 Return From Keyword If ${running_persistence_test} 304 305 FFDC On Test Case Fail 306 Run Keyword If '${TEST_STATUS}' == 'PASS' Check Error And Collect FFDC 307 Close All Connections 308