1*** Settings ***
2Documentation     Update the BMC code on a target BMC.
3...               Execution Method:
4...               python -m robot -v OPENBMC_HOST:<hostname>
5...               -v IMAGE_FILE_PATH:<path/*.tar>  bmc_code_update.robot
6
7Library           ../../lib/code_update_utils.py
8Library           ../../lib/gen_robot_keyword.py
9Variables         ../../data/variables.py
10Resource          ../../lib/utils.robot
11Resource          ../../lib/boot_utils.robot
12Resource          code_update_utils.robot
13Resource          ../../lib/code_update_utils.robot
14Resource          ../../lib/openbmc_ffdc.robot
15Resource          ../../lib/dump_utils.robot
16Resource          ../../lib/ipmi_client.robot
17Resource          ../../lib/certificate_utils.robot
18
19Suite Setup       Suite Setup Execution
20
21Test Teardown     Test Teardown Execution
22
23Force Tags        BMC_Code_Update
24
25*** Variables ***
26
27${QUIET}                          ${1}
28${IMAGE_FILE_PATH}                ${EMPTY}
29${ALTERNATE_IMAGE_FILE_PATH}      ${EMPTY}
30${SKIP_UPDATE_IF_ACTIVE}          false
31${dump_id}                        ${EMPTY}
32${running_persistence_test}       ${FALSE}
33${test_errlog_text}               AutoTestSimple
34
35*** Test Cases ***
36
37Test Basic BMC Performance Before BMC Code Update
38    [Documentation]  Check performance of memory, CPU & file system of BMC.
39    [Tags]  Test_Basic_BMC_Performance_Before_BMC_Code_Update
40
41    Open Connection And Log In
42    Check BMC Performance
43
44Prepare Persistent Data
45    [Documentation]  Set data that should persist across the code update.
46    [Tags]  Prepare_Persistent_Data
47
48    # Install the debug tarball.
49    BMC Execute Command  rm -rf /tmp/tarball
50    Install Debug Tarball On BMC  tarball_file_path=${DEBUG_TARBALL_PATH}
51
52    # Create a dummy error log and dump.
53    BMC Execute Command  /tmp/tarball/bin/logging-test -c ${test_errlog_text}
54    ${dump_id}=  Create User Initiated Dump
55    Check Dump Existence  ${dump_id}
56    Set Suite Variable  ${dump_id}
57
58    # Set persistent settings.
59    ${autoreboot_dict}=  Create Dictionary  data=${0}
60    Write Attribute  ${CONTROL_HOST_URI}auto_reboot  AutoReboot
61    ...  data=${autoreboot_dict}
62    ${onetime_dict}=  Create Dictionary  data=${0}
63    Write Attribute  ${CONTROL_HOST_URI}boot/one_time  Enabled
64    ...  data=${onetime_dict}
65
66    # Let the remaining test cases know we are doing a persistence test so we
67    # do not delete logs.
68    Set Suite Variable  ${running_persistence_test}  ${TRUE}
69
70
71REST BMC Code Update
72    [Documentation]  Do a BMC code update by uploading image on BMC via REST.
73    [Tags]  REST_BMC_Code_Update
74    [Teardown]  REST BMC Code Update Teardown
75
76    Run Keyword And Ignore Error  List Installed Images  BMC
77
78    Upload And Activate Image  ${IMAGE_FILE_PATH}
79    ...  skip_if_active=${SKIP_UPDATE_IF_ACTIVE}
80    OBMC Reboot (off)
81    Verify Running BMC Image  ${IMAGE_FILE_PATH}
82
83
84Verify Error Log Persistency
85    [Documentation]  Check that the error log is still present after a
86    ...              code update.
87    [Tags]  Verify_Error_Log_Persistency
88
89    ${error_log_paths}=  Read Properties  ${BMC_LOGGING_URI}/list
90    Log To Console  ${error_log_paths}
91    ${test_error_message}=  Read Attribute  @{error_log_paths}[-1]  Message
92    Should Be Equal  ${test_error_message}
93    ...  example.xyz.openbmc_project.Example.Elog.${test_errlog_text}
94    Delete Error Log Entry  @{error_log_paths}[-1]
95
96
97Verify BMC Dump Persistency
98    [Documentation]  Check that the BMC dump present after a code update.
99    [Tags]  Verify_BMC_Dump_Persistency
100    [Teardown]  Set Suite Variable  ${running_persistence_test}  ${FALSE}
101
102    Check Dump Existence  ${dump_id}
103    Delete BMC Dump  ${dump_id}
104
105
106Verify Settings Persistency
107    [Documentation]  Verify that the settings from 'Prepare Persistent Data'
108    ...              are still set correctly after the code update.
109    [Tags]  Verify_Settings_Persistency
110
111    ${autoreboot_enabled}=  Read Attribute  ${CONTROL_HOST_URI}auto_reboot
112    ...  AutoReboot
113    Should Be Equal  ${autoreboot_enabled}  ${0}
114    ${onetime_enabled}=  Read Attribute  ${CONTROL_HOST_URI}boot/one_time
115    ...  Enabled
116    Should Be Equal  ${onetime_enabled}  ${0}
117
118    # Set values back to their defaults
119    ${autoreboot_dict}=  Create Dictionary  data=${1}
120    Write Attribute  ${CONTROL_HOST_URI}auto_reboot  AutoReboot
121    ...  data=${autoreboot_dict}
122    ${onetime_dict}=  Create Dictionary  data=${1}
123    Write Attribute  ${CONTROL_HOST_URI}boot/one_time  Enabled
124    ...  data=${onetime_dict}
125
126
127Upload And Activate Multiple BMC Images
128    [Documentation]  Upload another BMC image and verify that its state is
129    ...              different from all others.
130    [Tags]  Upload_And_Activate_Multiple_BMC_Images
131    [Template]  Activate Image And Verify No Duplicate Priorities
132    [Setup]  Upload And Activate Multiple BMC Images Setup
133
134    # Image File Path              Image Purpose
135    ${ALTERNATE_IMAGE_FILE_PATH}   ${VERSION_PURPOSE_BMC}
136
137
138BMC Set Priority To Invalid Values
139    [Documentation]  Attempt to set the priority of an image to an invalid
140    ...              value and expect an error.
141    [Tags]  BMC_Set_Priority_To_Invalid_Values
142    [Template]  Set Priority To Invalid Value And Expect Error
143
144    # Version Type              Priority
145    ${VERSION_PURPOSE_BMC}     ${-1}
146    ${VERSION_PURPOSE_BMC}     ${256}
147
148
149Delete BMC Image
150    [Documentation]  Delete a BMC image from the BMC flash chip.
151    [Tags]  Delete_BMC_Image
152
153    ${software_object}=  Get Non Running BMC Software Object
154    Delete Image And Verify  ${software_object}  ${VERSION_PURPOSE_BMC}
155
156
157BMC Image Priority Attribute Test
158    [Documentation]  Set "Priority" attribute.
159    [Tags]  BMC_Image_Priority_Attribute_Test
160    [Template]  Temporarily Set BMC Attribute
161
162    # Property        Value
163    Priority          ${0}
164    Priority          ${1}
165    Priority          ${127}
166    Priority          ${255}
167
168
169Delete All Non Running BMC Images
170    [Documentation]  Delete all non running BMC images.
171    [Tags]  Delete_All_Non_Running_BMC_Images
172
173    ${version_id}=  Upload And Activate Image  ${ALTERNATE_IMAGE_FILE_PATH}
174    ...  skip_if_active=true
175    Delete All Non Running BMC Images
176
177    ${software_ids}=  Get Software Objects Id
178    ...  version_type=${VERSION_PURPOSE_BMC}
179    Should Not Contain  ${software_ids}  ${version_id}
180
181
182Verify IPMI Disable Policy Post BMC Code Update
183    [Documentation]  Disable IPMI, update BMC and verify post-update.
184    [Tags]  Verify_IPMI_Disable_Policy_Post_BMC_Code_Update
185
186    REST Power On
187
188    Run Inband IPMI Standard Command  lan set 1 access off
189    Run Keyword and Expect Error  *Unable to establish IPMI*
190    ...  Run External IPMI Standard Command  lan print
191
192    Upload And Activate Image  ${IMAGE_FILE_PATH}
193    ...  skip_if_active=${SKIP_UPDATE_IF_ACTIVE}
194    OBMC Reboot (off)
195    Verify Running BMC Image  ${IMAGE_FILE_PATH}
196
197    Run Keyword and Expect Error  *Unable to establish IPMI*
198    ...  Run External IPMI Standard Command  lan print
199
200
201Test Certificate Persistency After BMC Code Update
202    [Documentation]  Test certificate persistency after BMC update.
203    [Tags]  Test_Certificate_Persistency_After_BMC_Code_Update
204
205    ${cert_file_path}=  Generate Certificate File Via Openssl
206    ...  Valid Certificate Valid Privatekey
207    ${file_data}=  OperatingSystem.Get Binary File  ${cert_file_path}
208    ${cert_file_content}=  OperatingSystem.Get File  ${cert_file_path}
209
210    Install Certificate File On BMC  ${CLIENT_CERTIFICATE_URI}
211    ...  data=${file_data}
212
213    ${bmc_cert_content}=  Get Certificate File Content From BMC  Client
214    Should Contain  ${cert_file_content}  ${bmc_cert_content}
215
216    Upload And Activate Image  ${IMAGE_FILE_PATH}
217    ...  skip_if_active=${SKIP_UPDATE_IF_ACTIVE}
218    OBMC Reboot (off)
219    Verify Running BMC Image  ${IMAGE_FILE_PATH}
220
221    ${bmc_cert_content}=  Get Certificate File Content From BMC  Client
222    Should Contain  ${cert_file_content}  ${bmc_cert_content}
223
224
225Test Basic BMC Performance After Code Update
226    [Documentation]  Check performance of memory, CPU & file system of BMC.
227    [Tags]  Test_Basic_BMC_Performance_After_Code_Update
228
229    Open Connection And Log In
230    Check BMC Performance
231
232
233*** Keywords ***
234
235Temporarily Set BMC Attribute
236    [Documentation]  Update the BMC attribute value.
237    [Arguments]  ${attribute_name}  ${attribute_value}
238
239    # Description of argument(s):
240    # attribute_name    BMC software attribute name (e.g. "Priority").
241    # attribute_value   Value to be written.
242
243    ${image_ids}=  Get Software Objects  ${VERSION_PURPOSE_BMC}
244    ${init_bmc_properties}=  Get Host Software Property  ${image_ids[0]}
245    ${initial_priority}=  Set Variable  ${init_bmc_properties["Priority"]}
246
247    Set Host Software Property  ${image_ids[0]}  ${attribute_name}
248    ...  ${attribute_value}
249
250    ${cur_bmc_properties}=  Get Host Software Property  ${image_ids[0]}
251    Should Be Equal As Integers  ${cur_bmc_properties["Priority"]}
252    ...  ${attribute_value}
253
254    # Revert to to initial value.
255    Set Host Software Property
256    ...  ${image_ids[0]}  ${attribute_name}  ${initial_priority}
257
258
259Upload And Activate Multiple BMC Images Setup
260    [Documentation]  Check that the ALTERNATE_FILE_PATH variable is set.
261
262    Should Not Be Empty  ${ALTERNATE_IMAGE_FILE_PATH}
263
264
265REST BMC Code Update Teardown
266    [Documentation]  Do code update test teardown.
267
268    FFDC On Test Case Fail
269    Run Keyword If Test Failed  Fatal Error  msg=Code update failed.
270
271
272Suite Setup Execution
273    [Documentation]  Do code update test case setup.
274    # - Clean up all existing BMC dumps.
275
276    Run Key  Delete All Dumps  ignore=1
277    Run Keyword And Ignore Error  Smart Power Off
278
279Test Teardown Execution
280    [Documentation]  Do code update test case teardown.
281    # 1. Collect FFDC if test case failed.
282    # 2. Collect FFDC if test PASS but error log exists.
283
284    # Don't delete our logs if we want to persist them for tests.
285    Return From Keyword If  ${running_persistence_test}
286
287    FFDC On Test Case Fail
288    Run Keyword If  '${TEST_STATUS}' == 'PASS'  Check Error And Collect FFDC
289    Close All Connections
290