1*** Settings *** 2Documentation Update the BMC code on a target BMC. 3... Execution Method: 4... python -m robot -v OPENBMC_HOST:<hostname> 5... -v IMAGE_FILE_PATH:<path/*.tar> bmc_code_update.robot 6 7Library ../../lib/code_update_utils.py 8Library ../../lib/gen_robot_keyword.py 9Variables ../../data/variables.py 10Resource ../../lib/utils.robot 11Resource ../../lib/boot_utils.robot 12Resource code_update_utils.robot 13Resource ../../lib/code_update_utils.robot 14Resource ../../lib/openbmc_ffdc.robot 15Resource ../../lib/dump_utils.robot 16Resource ../../lib/certificate_utils.robot 17 18Suite Setup Suite Setup Execution 19 20Test Teardown Test Teardown Execution 21 22Force Tags BMC_Code_Update 23 24*** Variables *** 25 26${QUIET} ${1} 27${IMAGE_FILE_PATH} ${EMPTY} 28${ALTERNATE_IMAGE_FILE_PATH} ${EMPTY} 29${SKIP_UPDATE_IF_ACTIVE} false 30${dump_id} ${EMPTY} 31${running_persistence_test} ${FALSE} 32${test_errlog_text} AutoTestSimple 33 34*** Test Cases *** 35 36Test Basic BMC Performance Before BMC Code Update 37 [Documentation] Check performance of memory, CPU & file system of BMC. 38 [Tags] Test_Basic_BMC_Performance_Before_BMC_Code_Update 39 40 Open Connection And Log In 41 Check BMC Performance 42 43Prepare Persistent Data 44 [Documentation] Set data that should persist across the code update. 45 [Tags] Prepare_Persistent_Data 46 47 # Install the debug tarball. 48 BMC Execute Command rm -rf /tmp/tarball 49 Install Debug Tarball On BMC tarball_file_path=${DEBUG_TARBALL_PATH} 50 51 # Create a dummy error log and dump. 52 BMC Execute Command /tmp/tarball/bin/logging-test -c ${test_errlog_text} 53 ${dump_id}= Create User Initiated Dump 54 Check Dump Existence ${dump_id} 55 Set Suite Variable ${dump_id} 56 57 # Set persistent settings. 58 ${autoreboot_dict}= Create Dictionary data=${0} 59 Write Attribute ${CONTROL_HOST_URI}auto_reboot AutoReboot 60 ... data=${autoreboot_dict} 61 ${onetime_dict}= Create Dictionary data=${0} 62 Write Attribute ${CONTROL_HOST_URI}boot/one_time Enabled 63 ... data=${onetime_dict} 64 65 # Let the remaining test cases know we are doing a persistence test so we 66 # do not delete logs. 67 Set Suite Variable ${running_persistence_test} ${TRUE} 68 69 70REST BMC Code Update 71 [Documentation] Do a BMC code update by uploading image on BMC via REST. 72 [Tags] REST_BMC_Code_Update 73 [Teardown] REST BMC Code Update Teardown 74 75 Run Keyword And Ignore Error List Installed Images BMC 76 77 Upload And Activate Image ${IMAGE_FILE_PATH} 78 ... skip_if_active=${SKIP_UPDATE_IF_ACTIVE} 79 OBMC Reboot (off) 80 Verify Running BMC Image ${IMAGE_FILE_PATH} 81 BMC Execute Command cd /etc ; cat host.conf hosts hostname print_out=1 82 83 84Verify Error Log Persistency 85 [Documentation] Check that the error log is still present after a 86 ... code update. 87 [Tags] Verify_Error_Log_Persistency 88 89 ${error_log_paths}= Read Properties ${BMC_LOGGING_ENTRY}list 90 Log To Console ${error_log_paths} 91 ${test_error_message}= Read Attribute @{error_log_paths}[-1] Message 92 Should Be Equal ${test_error_message} 93 ... example.xyz.openbmc_project.Example.Elog.${test_errlog_text} 94 Delete Error Log Entry @{error_log_paths}[-1] 95 96 97Verify BMC Dump Persistency 98 [Documentation] Check that the BMC dump present after a code update. 99 [Tags] Verify_BMC_Dump_Persistency 100 [Teardown] Set Suite Variable ${running_persistence_test} ${FALSE} 101 102 Check Dump Existence ${dump_id} 103 Delete BMC Dump ${dump_id} 104 105 106Verify Settings Persistency 107 [Documentation] Verify that the settings from 'Prepare Persistent Data' 108 ... are still set correctly after the code update. 109 [Tags] Verify_Settings_Persistency 110 111 ${autoreboot_enabled}= Read Attribute ${CONTROL_HOST_URI}auto_reboot 112 ... AutoReboot 113 Should Be Equal ${autoreboot_enabled} ${0} 114 ${onetime_enabled}= Read Attribute ${CONTROL_HOST_URI}boot/one_time 115 ... Enabled 116 Should Be Equal ${onetime_enabled} ${0} 117 118 # Set values back to their defaults 119 ${autoreboot_dict}= Create Dictionary data=${1} 120 Write Attribute ${CONTROL_HOST_URI}auto_reboot AutoReboot 121 ... data=${autoreboot_dict} 122 ${onetime_dict}= Create Dictionary data=${1} 123 Write Attribute ${CONTROL_HOST_URI}boot/one_time Enabled 124 ... data=${onetime_dict} 125 126 127Upload And Activate Multiple BMC Images 128 [Documentation] Upload another BMC image and verify that its state is 129 ... different from all others. 130 [Tags] Upload_And_Activate_Multiple_BMC_Images 131 [Template] Activate Image And Verify No Duplicate Priorities 132 [Setup] Upload And Activate Multiple BMC Images Setup 133 134 # Image File Path Image Purpose 135 ${ALTERNATE_IMAGE_FILE_PATH} ${VERSION_PURPOSE_BMC} 136 137 138BMC Set Priority To Invalid Values 139 [Documentation] Attempt to set the priority of an image to an invalid 140 ... value and expect an error. 141 [Tags] BMC_Set_Priority_To_Invalid_Values 142 [Template] Set Priority To Invalid Value And Expect Error 143 144 # Version Type Priority 145 ${VERSION_PURPOSE_BMC} ${-1} 146 ${VERSION_PURPOSE_BMC} ${256} 147 148 149Delete BMC Image 150 [Documentation] Delete a BMC image from the BMC flash chip. 151 [Tags] Delete_BMC_Image 152 153 ${software_object}= Get Non Running BMC Software Object 154 Delete Image And Verify ${software_object} ${VERSION_PURPOSE_BMC} 155 156 157BMC Image Priority Attribute Test 158 [Documentation] Set "Priority" attribute. 159 [Tags] BMC_Image_Priority_Attribute_Test 160 [Template] Temporarily Set BMC Attribute 161 162 # Property Value 163 Priority ${False} 164 Priority ${True} 165 Priority ${0} 166 Priority ${1} 167 Priority ${127} 168 Priority ${255} 169 170 171Delete All Non Running BMC Images 172 [Documentation] Delete all non running BMC images. 173 [Tags] Delete_All_Non_Running_BMC_Images 174 175 ${version_id}= Upload And Activate Image ${ALTERNATE_IMAGE_FILE_PATH} 176 ... skip_if_active=true 177 Delete All Non Running BMC Images 178 179 ${software_ids}= Get Software Objects Id 180 ... version_type=${VERSION_PURPOSE_BMC} 181 Should Not Contain ${software_ids} ${version_id} 182 183 184Test Certificate Persistency After BMC Code Update 185 [Documentation] Test certificate persistency after BMC update. 186 [Tags] Test_Certificate_Persistency_After_BMC_Code_Update 187 188 # Create certificate sub-directory in current working directory. 189 Create Directory certificate_dir 190 OperatingSystem.Directory Should Exist ${EXECDIR}${/}certificate_dir 191 192 ${cert_file_path}= Generate Certificate File Via Openssl 193 ... Valid Certificate Valid Privatekey 194 ${file_data}= OperatingSystem.Get Binary File ${cert_file_path} 195 ${cert_file_content}= OperatingSystem.Get File ${cert_file_path} 196 197 Install Certificate File On BMC ${CLIENT_CERTIFICATE_URI} 198 ... data=${file_data} 199 200 ${bmc_cert_content}= Get Certificate File Content From BMC Client 201 Should Contain ${cert_file_content} ${bmc_cert_content} 202 203 Upload And Activate Image ${IMAGE_FILE_PATH} 204 ... skip_if_active=${SKIP_UPDATE_IF_ACTIVE} 205 OBMC Reboot (off) 206 Verify Running BMC Image ${IMAGE_FILE_PATH} 207 208 ${bmc_cert_content}= Get Certificate File Content From BMC Client 209 Should Contain ${cert_file_content} ${bmc_cert_content} 210 211 212Test Basic BMC Performance After Code Update 213 [Documentation] Check performance of memory, CPU & file system of BMC. 214 [Tags] Test_Basic_BMC_Performance_After_Code_Update 215 216 Open Connection And Log In 217 Check BMC Performance 218 219 220*** Keywords *** 221 222Temporarily Set BMC Attribute 223 [Documentation] Update the BMC attribute value. 224 [Arguments] ${attribute_name} ${attribute_value} 225 226 # Description of argument(s): 227 # attribute_name BMC software attribute name (e.g. "Priority"). 228 # attribute_value Value to be written. 229 230 ${image_ids}= Get Software Objects ${VERSION_PURPOSE_BMC} 231 ${init_bmc_properties}= Get Host Software Property ${image_ids[0]} 232 ${initial_priority}= Set Variable ${init_bmc_properties["Priority"]} 233 234 Set Host Software Property ${image_ids[0]} ${attribute_name} 235 ... ${attribute_value} 236 237 ${cur_bmc_properties}= Get Host Software Property ${image_ids[0]} 238 Should Be Equal As Integers ${cur_bmc_properties["Priority"]} 239 ... ${attribute_value} 240 241 # Revert to to initial value. 242 Set Host Software Property 243 ... ${image_ids[0]} ${attribute_name} ${initial_priority} 244 245 246Upload And Activate Multiple BMC Images Setup 247 [Documentation] Check that the ALTERNATE_FILE_PATH variable is set. 248 249 Should Not Be Empty ${ALTERNATE_IMAGE_FILE_PATH} 250 251 252REST BMC Code Update Teardown 253 [Documentation] Do code update test teardown. 254 255 FFDC On Test Case Fail 256 Run Keyword If Test Failed Fatal Error msg=Code update failed. 257 258 259Suite Setup Execution 260 [Documentation] Do code update test case setup. 261 # - Clean up all existing BMC dumps. 262 263 Run Key Delete All Dumps ignore=1 264 Run Keyword And Ignore Error Smart Power Off 265 266Test Teardown Execution 267 [Documentation] Do code update test case teardown. 268 # 1. Collect FFDC if test case failed. 269 # 2. Collect FFDC if test PASS but error log exists. 270 271 # Don't delete our logs if we want to persist them for tests. 272 Return From Keyword If ${running_persistence_test} 273 274 FFDC On Test Case Fail 275 Run Keyword If '${TEST_STATUS}' == 'PASS' Check Error And Collect FFDC 276 Close All Connections 277 278 279