1import os 2 3OPENBMC_BASE_URI = '/xyz/openbmc_project/' 4OPENBMC_BASE_DBUS = 'xyz.openbmc_project.' 5 6# org open power base URI. 7OPENPOWER_BASE_URI = '/org/open_power/' 8OPENPOWER_CONTROL = OPENPOWER_BASE_URI + 'control/' 9OPENPOWER_SENSORS = OPENPOWER_BASE_URI + 'sensors/' 10 11# REST URI base endpoint paths. 12CONTROL_URI = OPENBMC_BASE_URI + 'control/' 13# old vs new code dependencies in many places. 14# TODO: remove when ready. 15SETTINGS_URI = '/org/openbmc/settings/' 16WATCHDOG_URI = OPENBMC_BASE_URI + 'watchdog/' 17TIME_MANAGER_URI = OPENBMC_BASE_URI + 'time/' 18NETWORK_MANAGER = OPENBMC_BASE_URI + 'network/' 19# SNMP 20SNMP_MANAGER_URI = NETWORK_MANAGER + 'snmp/manager/' 21# Sensors base variables. 22SENSORS_URI = OPENBMC_BASE_URI + 'sensors/' 23 24# State Manager base variables 25BMC_REBOOT_TRANS = 'xyz.openbmc_project.State.BMC.Transition.Reboot' 26 27HOST_POWEROFF_TRANS = 'xyz.openbmc_project.State.Host.Transition.Off' 28HOST_POWERON_TRANS = 'xyz.openbmc_project.State.Host.Transition.On' 29HOST_REBOOT_TRANS = 'xyz.openbmc_project.State.Host.Transition.Reboot' 30HOST_POWEROFF_STATE = 'xyz.openbmc_project.State.Host.HostState.Off' 31HOST_POWERON_STATE = 'xyz.openbmc_project.State.Host.HostState.Running' 32 33CHASSIS_POWEROFF_TRANS = 'xyz.openbmc_project.State.Chassis.Transition.Off' 34CHASSIS_POWERON_TRANS = 'xyz.openbmc_project.State.Chassis.Transition.On' 35CHASSIS_POWEROFF_STATE = 'xyz.openbmc_project.State.Chassis.PowerState.Off' 36CHASSIS_POWERON_STATE = 'xyz.openbmc_project.State.Chassis.PowerState.On' 37 38# State Manager URI variables. 39SYSTEM_STATE_URI = OPENBMC_BASE_URI + 'state/' 40BMC_STATE_URI = OPENBMC_BASE_URI + 'state/bmc0/' 41HOST_STATE_URI = OPENBMC_BASE_URI + 'state/host0/' 42CHASSIS_STATE_URI = OPENBMC_BASE_URI + 'state/chassis0/' 43HOST_WATCHDOG_URI = OPENBMC_BASE_URI + 'watchdog/host0/' 44 45# Logging URI variables 46BMC_LOGGING_URI = OPENBMC_BASE_URI + 'logging/' 47BMC_LOGGING_ENTRY = BMC_LOGGING_URI + 'entry/' 48 49# Software manager version 50SOFTWARE_VERSION_URI = OPENBMC_BASE_URI + 'software/' 51ACTIVE = 'xyz.openbmc_project.Software.Activation.Activations.Active' 52READY = 'xyz.openbmc_project.Software.Activation.Activations.Ready' 53INVALID = 'xyz.openbmc_project.Software.Activation.Activations.Invalid' 54ACTIVATING = 'xyz.openbmc_project.Software.Activation.Activations.Activating' 55NOTREADY = 'xyz.openbmc_project.Software.Activation.Activations.NotReady' 56FAILED = 'xyz.openbmc_project.Software.Activation.Activations.Failed' 57 58SOFTWARE_ACTIVATION = 'xyz.openbmc_project.Software.Activation' 59REQUESTED_ACTIVATION = SOFTWARE_ACTIVATION + '.RequestedActivations' 60REQUESTED_ACTIVE = REQUESTED_ACTIVATION + '.Active' 61REQUESTED_NONE = REQUESTED_ACTIVATION + '.None' 62 63SOFTWARE_PURPOSE = 'xyz.openbmc_project.Software.Version.VersionPurpose' 64VERSION_PURPOSE_HOST = SOFTWARE_PURPOSE + '.Host' 65VERSION_PURPOSE_BMC = SOFTWARE_PURPOSE + '.BMC' 66VERSION_PURPOSE_SYSTEM = SOFTWARE_PURPOSE + '.System' 67 68# Image Upload Directory Path 69IMAGE_UPLOAD_DIR_PATH = '/tmp/images/' 70 71# Inventory URI 72HOST_INVENTORY_URI = OPENBMC_BASE_URI + 'inventory/' 73 74# Led URI variable 75LED_GROUPS_URI = OPENBMC_BASE_URI + 'led/groups/' 76LED_PHYSICAL_URI = OPENBMC_BASE_URI + 'led/physical/' 77 78# Host control URI variables. 79CONTROL_HOST_URI = OPENBMC_BASE_URI + 'control/host0/' 80 81# Power restore variables. 82POWER_RESTORE_URI = CONTROL_HOST_URI + 'power_restore_policy' 83CONTROL_DBUS_BASE = 'xyz.openbmc_project.Control.' 84 85RESTORE_LAST_STATE = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.Restore' 86ALWAYS_POWER_ON = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.AlwaysOn' 87ALWAYS_POWER_OFF = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.AlwaysOff' 88 89# Dump URI variables. 90DUMP_URI = OPENBMC_BASE_URI + 'dump/' 91DUMP_ENTRY_URI = DUMP_URI + 'entry/' 92DUMP_DOWNLOAD_URI = "/download/dump/" 93# The path on the BMC where dumps are stored. 94DUMP_DIR_PATH = "/var/lib/phosphor-debug-collector/dumps/" 95 96# Boot progress variables. 97STATE_DBUS_BASE = 'xyz.openbmc_project.State.' 98OS_BOOT_START = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.OSStart' 99OS_BOOT_OFF = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.Unspecified' 100OS_BOOT_PCI = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.PCIInit' 101OS_BOOT_SECPCI = STATE_DBUS_BASE + \ 102 'Boot.Progress.ProgressStages.SecondaryProcInit' 103OS_BOOT_MEM = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.MemoryInit' 104OS_BOOT_MOTHERBOARD = STATE_DBUS_BASE + \ 105 'Boot.Progress.ProgressStages.MotherboardInit' 106 107# OperatingSystem status variables. 108OS_BOOT_COMPLETE = STATE_DBUS_BASE + \ 109 'OperatingSystem.Status.OSStatus.BootComplete' 110OS_BOOT_CDROM = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.CDROMBoot' 111OS_BOOT_ROM = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.ROMBoot' 112OS_BOOT_PXE = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.PXEBoot' 113OS_BOOT_CBoot = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.CBoot' 114OS_BOOT_DiagBoot = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.DiagBoot' 115 116# Boot variables. 117BOOT_SOURCE_DEFAULT = 'xyz.openbmc_project.Control.Boot.Source.Sources.Default' 118BOOT_SOURCE_NETWORK = 'xyz.openbmc_project.Control.Boot.Source.Sources.Network' 119BOOT_SOURCE_DISK = 'xyz.openbmc_project.Control.Boot.Source.Sources.Disk' 120BOOT_SOURCE_CDROM = 'xyz.openbmc_project.Control.Boot.Source.Sources.ExternalMedia' 121BOOT_MODE_SAFE = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Safe' 122BOOT_MODE_SETUP = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Setup' 123BOOT_MODE_REGULAR = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Regular' 124 125# Time variables. 126TIME_DBUS_BASE = 'xyz.openbmc_project.Time.' 127BMC_OWNER = TIME_DBUS_BASE + 'Owner.Owners.BMC' 128HOST_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Host' 129SPLIT_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Split' 130BOTH_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Both' 131NTP_MODE = TIME_DBUS_BASE + 'Synchronization.Method.NTP' 132MANUAL_MODE = TIME_DBUS_BASE + 'Synchronization.Method.Manual' 133 134# User manager variable. 135BMC_USER_URI = OPENBMC_BASE_URI + 'user/' 136 137# LDAP User manager variable. 138BMC_LDAP_URI = BMC_USER_URI + 'ldap' 139 140# The path on the BMC where signed keys are stored. 141ACTIVATION_DIR_PATH = "/etc/activationdata/" 142 143# Redfish variables. 144REDFISH_BASE_URI = '/redfish/v1/' 145REDFISH_SESSION = REDFISH_BASE_URI + 'SessionService/Sessions' 146REDFISH_SESSION_URI = 'SessionService/Sessions/' 147REDFISH_NW_ETH0 = 'Managers/bmc/EthernetInterfaces/eth0/' 148REDFISH_NW_ETH0_URI = REDFISH_BASE_URI + REDFISH_NW_ETH0 149REDFISH_NW_PROTOCOL = 'Managers/bmc/NetworkProtocol' 150REDFISH_NW_PROTOCOL_URI = REDFISH_BASE_URI + REDFISH_NW_PROTOCOL 151REDFISH_ACCOUNTS_SERVICE = 'AccountService/' 152REDFISH_ACCOUNTS_SERVICE_URI = REDFISH_BASE_URI + REDFISH_ACCOUNTS_SERVICE 153REDFISH_ACCOUNTS = 'AccountService/Accounts/' 154REDFISH_ACCOUNTS_URI = REDFISH_BASE_URI + REDFISH_ACCOUNTS 155REDFISH_HTTPS_CERTIFICATE = 'Managers/bmc/NetworkProtocol/HTTPS/Certificates' 156REDFISH_HTTPS_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_HTTPS_CERTIFICATE 157REDFISH_LDAP_CERTIFICATE = 'AccountService/LDAP/Certificates' 158REDFISH_LDAP_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_LDAP_CERTIFICATE 159REDFISH_CA_CERTIFICATE = 'Managers/bmc/Truststore/Certificates' 160REDFISH_CA_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_CA_CERTIFICATE 161REDFISH_CHASSIS_URI = REDFISH_BASE_URI + 'Chassis/' 162REDFISH_CHASSIS_THERMAL = 'chassis/Thermal/' 163REDFISH_CHASSIS_THERMAL_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_THERMAL 164REDFISH_CHASSIS_POWER = 'chassis/Power/' 165REDFISH_CHASSIS_POWER_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_POWER 166REDFISH_CHASSIS_PSUPPLY0 = 'powersupply0/Power/' 167REDFISH_CHASSIS_PSUPPLY1 = 'powersupply1/Power/' 168REDFISH_CHASSIS_PSUPPLY0_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_PSUPPLY0 169REDFISH_CHASSIS_PSUPPLY1_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_PSUPPLY1 170 171# Boot options and URI variables. 172POWER_ON = 'On' 173POWER_GRACEFUL_OFF = "GracefulShutdown" 174POWER_GRACEFUL_RESTART = "GracefulRestart" 175POWER_FORCE_OFF = 'ForceOff' 176 177REDFISH_POWER = 'Systems/system/Actions/ComputerSystem.Reset' 178REDFISH_POWER_URI = REDFISH_BASE_URI + REDFISH_POWER 179 180# rsyslog variables. 181REMOTE_LOGGING_URI = OPENBMC_BASE_URI + 'logging/config/remote/' 182 183# Certificate variables. 184SERVER_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/server/https' 185CLIENT_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/client/ldap' 186CA_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/authority/ldap' 187 188# EventLog variables. 189SYSTEM_BASE_URI = REDFISH_BASE_URI + 'Systems/system/' 190EVENT_LOG_URI = SYSTEM_BASE_URI + 'LogServices/EventLog/' 191 192 193''' 194 QEMU HTTPS variable: 195 196 By default lib/resource.robot AUTH URI construct is as 197 ${AUTH_URI} https://${OPENBMC_HOST}${AUTH_SUFFIX} 198 ${AUTH_SUFFIX} is populated here by default EMPTY else 199 the port from the OS environment 200''' 201 202 203def get_port_https(): 204 # defaulted to empty string 205 l_suffix = '' 206 try: 207 l_https_port = os.getenv('HTTPS_PORT') 208 if l_https_port: 209 l_suffix = ':' + l_https_port 210 except BaseException: 211 print ("Environment variable HTTPS_PORT not set,\ 212 using default HTTPS port") 213 return l_suffix 214 215 216AUTH_SUFFIX = { 217 "https_port": [get_port_https()], 218} 219 220# Update the ':Port number' to this variable 221AUTH_SUFFIX = AUTH_SUFFIX['https_port'][0] 222 223# Here contains a list of valid Properties bases on fru_type after a boot. 224INVENTORY_ITEMS = { 225 "CPU": [ 226 "Custom Field 1", 227 "Custom Field 2", 228 "Custom Field 3", 229 "Custom Field 4", 230 "Custom Field 5", 231 "Custom Field 6", 232 "Custom Field 7", 233 "Custom Field 8", 234 "FRU File ID", 235 "Manufacturer", 236 "Name", 237 "Part Number", 238 "Serial Number", 239 "fault", 240 "fru_type", 241 "is_fru", 242 "present", 243 "version", 244 ], 245 246 "DIMM": [ 247 "Asset Tag", 248 "Custom Field 1", 249 "Custom Field 2", 250 "Custom Field 3", 251 "Custom Field 4", 252 "Custom Field 5", 253 "Custom Field 6", 254 "Custom Field 7", 255 "Custom Field 8", 256 "FRU File ID", 257 "Manufacturer", 258 "Model Number", 259 "Name", 260 "Serial Number", 261 "Version", 262 "fault", 263 "fru_type", 264 "is_fru", 265 "present", 266 "version", 267 ], 268 "MEMORY_BUFFER": [ 269 "Custom Field 1", 270 "Custom Field 2", 271 "Custom Field 3", 272 "Custom Field 4", 273 "Custom Field 5", 274 "Custom Field 6", 275 "Custom Field 7", 276 "Custom Field 8", 277 "FRU File ID", 278 "Manufacturer", 279 "Name", 280 "Part Number", 281 "Serial Number", 282 "fault", 283 "fru_type", 284 "is_fru", 285 "present", 286 "version", 287 ], 288 "FAN": [ 289 "fault", 290 "fru_type", 291 "is_fru", 292 "present", 293 "version", 294 ], 295 "DAUGHTER_CARD": [ 296 "Custom Field 1", 297 "Custom Field 2", 298 "Custom Field 3", 299 "Custom Field 4", 300 "Custom Field 5", 301 "Custom Field 6", 302 "Custom Field 7", 303 "Custom Field 8", 304 "FRU File ID", 305 "Manufacturer", 306 "Name", 307 "Part Number", 308 "Serial Number", 309 "fault", 310 "fru_type", 311 "is_fru", 312 "present", 313 "version", 314 ], 315 "BMC": [ 316 "fault", 317 "fru_type", 318 "is_fru", 319 "manufacturer", 320 "present", 321 "version", 322 ], 323 "MAIN_PLANAR": [ 324 "Custom Field 1", 325 "Custom Field 2", 326 "Custom Field 3", 327 "Custom Field 4", 328 "Custom Field 5", 329 "Custom Field 6", 330 "Custom Field 7", 331 "Custom Field 8", 332 "Part Number", 333 "Serial Number", 334 "Type", 335 "fault", 336 "fru_type", 337 "is_fru", 338 "present", 339 "version", 340 ], 341 "SYSTEM": [ 342 "Custom Field 1", 343 "Custom Field 2", 344 "Custom Field 3", 345 "Custom Field 4", 346 "Custom Field 5", 347 "Custom Field 6", 348 "Custom Field 7", 349 "Custom Field 8", 350 "FRU File ID", 351 "Manufacturer", 352 "Model Number", 353 "Name", 354 "Serial Number", 355 "Version", 356 "fault", 357 "fru_type", 358 "is_fru", 359 "present", 360 "version", 361 ], 362 "CORE": [ 363 "fault", 364 "fru_type", 365 "is_fru", 366 "present", 367 "version", 368 ], 369} 370