1import os 2 3OPENBMC_BASE_URI = '/xyz/openbmc_project/' 4OPENBMC_BASE_DBUS = 'xyz.openbmc_project.' 5 6# org open power base URI. 7OPENPOWER_BASE_URI = '/org/open_power/' 8OPENPOWER_CONTROL = OPENPOWER_BASE_URI + 'control/' 9 10# REST URI base endpoint paths. 11CONTROL_URI = OPENBMC_BASE_URI + 'control/' 12# old vs new code dependencies in many places. 13# TODO: remove when ready. 14SETTINGS_URI = '/org/openbmc/settings/' 15WATCHDOG_URI = OPENBMC_BASE_URI + 'watchdog/' 16TIME_MANAGER_URI = OPENBMC_BASE_URI + 'time/' 17XYZ_NETWORK_MANAGER = OPENBMC_BASE_URI + 'network/' 18 19# Sensors base variables. 20SENSORS_URI = OPENBMC_BASE_URI + 'sensors/' 21 22# State Manager base variables 23BMC_REBOOT_TRANS = 'xyz.openbmc_project.State.BMC.Transition.Reboot' 24 25HOST_POWEROFF_TRANS = 'xyz.openbmc_project.State.Host.Transition.Off' 26HOST_POWERON_TRANS = 'xyz.openbmc_project.State.Host.Transition.On' 27HOST_REBOOT_TRANS = 'xyz.openbmc_project.State.Host.Transition.Reboot' 28HOST_POWEROFF_STATE = 'xyz.openbmc_project.State.Host.HostState.Off' 29HOST_POWERON_STATE = 'xyz.openbmc_project.State.Host.HostState.Running' 30 31CHASSIS_POWEROFF_TRANS = 'xyz.openbmc_project.State.Chassis.Transition.Off' 32CHASSIS_POWERON_TRANS = 'xyz.openbmc_project.State.Chassis.Transition.On' 33CHASSIS_POWEROFF_STATE = 'xyz.openbmc_project.State.Chassis.PowerState.Off' 34CHASSIS_POWERON_STATE = 'xyz.openbmc_project.State.Chassis.PowerState.On' 35 36# State Manager URI variables. 37SYSTEM_STATE_URI = OPENBMC_BASE_URI + 'state/' 38BMC_STATE_URI = OPENBMC_BASE_URI + 'state/bmc0/' 39HOST_STATE_URI = OPENBMC_BASE_URI + 'state/host0/' 40CHASSIS_STATE_URI = OPENBMC_BASE_URI + 'state/chassis0/' 41HOST_WATCHDOG_URI = OPENBMC_BASE_URI + 'watchdog/host0/' 42 43# Logging URI variables 44BMC_LOGGING_URI = OPENBMC_BASE_URI + 'logging/' 45BMC_LOGGING_ENTRY = BMC_LOGGING_URI + 'entry/' 46 47# Software manager version 48SOFTWARE_VERSION_URI = OPENBMC_BASE_URI + 'software/' 49ACTIVE = 'xyz.openbmc_project.Software.Activation.Activations.Active' 50READY = 'xyz.openbmc_project.Software.Activation.Activations.Ready' 51INVALID = 'xyz.openbmc_project.Software.Activation.Activations.Invalid' 52ACTIVATING = 'xyz.openbmc_project.Software.Activation.Activations.Activating' 53NOTREADY = 'xyz.openbmc_project.Software.Activation.Activations.NotReady' 54FAILED = 'xyz.openbmc_project.Software.Activation.Activations.Failed' 55 56SOFTWARE_ACTIVATION = 'xyz.openbmc_project.Software.Activation' 57REQUESTED_ACTIVATION = SOFTWARE_ACTIVATION + '.RequestedActivations' 58REQUESTED_ACTIVE = REQUESTED_ACTIVATION + '.Active' 59REQUESTED_NONE = REQUESTED_ACTIVATION + '.None' 60 61SOFTWARE_PURPOSE = 'xyz.openbmc_project.Software.Version.VersionPurpose' 62VERSION_PURPOSE_HOST = SOFTWARE_PURPOSE + '.Host' 63VERSION_PURPOSE_BMC = SOFTWARE_PURPOSE + '.BMC' 64VERSION_PURPOSE_SYSTEM = SOFTWARE_PURPOSE + '.System' 65 66# Image Upload Directory Path 67IMAGE_UPLOAD_DIR_PATH = '/tmp/images/' 68 69# Inventory URI 70HOST_INVENTORY_URI = OPENBMC_BASE_URI + 'inventory/' 71 72# Led URI variable 73LED_GROUPS_URI = OPENBMC_BASE_URI + 'led/groups/' 74LED_PHYSICAL_URI = OPENBMC_BASE_URI + 'led/physical/' 75 76# Host control URI variables. 77CONTROL_HOST_URI = OPENBMC_BASE_URI + 'control/host0/' 78 79# Power restore variables. 80POWER_RESTORE_URI = CONTROL_HOST_URI + 'power_restore_policy' 81CONTROL_DBUS_BASE = 'xyz.openbmc_project.Control.' 82 83RESTORE_LAST_STATE = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.Restore' 84ALWAYS_POWER_ON = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.AlwaysOn' 85ALWAYS_POWER_OFF = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.AlwaysOff' 86 87# Dump URI variable 88DUMP_URI = OPENBMC_BASE_URI +'/dump/' 89DUMP_ENTRY_URI = DUMP_URI + 'entry/' 90# The path on the BMC where dumps are stored. 91DUMP_DIR_PATH = "/var/lib/phosphor-debug-collector/dumps/" 92 93# Boot progress variables. 94STATE_DBUS_BASE = 'xyz.openbmc_project.State.' 95OS_BOOT_START = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.OSStart' 96OS_BOOT_OFF = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.Unspecified' 97OS_BOOT_COMPLETE = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.BootComplete' 98 99# Boot variables. 100BOOT_SOURCE_DEFAULT = 'xyz.openbmc_project.Control.Boot.Source.Sources.Default' 101BOOT_SOURCE_NETWORK = 'xyz.openbmc_project.Control.Boot.Source.Sources.Network' 102BOOT_SOURCE_DISK = 'xyz.openbmc_project.Control.Boot.Source.Sources.Disk' 103BOOT_SOURCE_CDROM = 'xyz.openbmc_project.Control.Boot.Source.Sources.ExternalMedia' 104BOOT_MODE_SAFE = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Safe' 105BOOT_MODE_SETUP = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Setup' 106BOOT_MODE_REGULAR = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Regular' 107 108''' 109 QEMU HTTPS variable: 110 111 By default lib/resource.txt AUTH URI construct is as 112 ${AUTH_URI} https://${OPENBMC_HOST}${AUTH_SUFFIX} 113 ${AUTH_SUFFIX} is populated here by default EMPTY else 114 the port from the OS environment 115''' 116 117 118def get_port_https(): 119 # defaulted to empty string 120 l_suffix = '' 121 try: 122 l_https_port = os.getenv('HTTPS_PORT') 123 if l_https_port: 124 l_suffix = ':' + l_https_port 125 except: 126 print "Environment variable HTTPS_PORT not set,\ 127 using default HTTPS port" 128 return l_suffix 129 130AUTH_SUFFIX = { 131 "https_port": [get_port_https()], 132} 133 134# Update the ':Port number' to this variable 135AUTH_SUFFIX = AUTH_SUFFIX['https_port'][0] 136 137# Here contains a list of valid Properties bases on fru_type after a boot. 138INVENTORY_ITEMS = { 139 "CPU": [ 140 "Custom Field 1", 141 "Custom Field 2", 142 "Custom Field 3", 143 "Custom Field 4", 144 "Custom Field 5", 145 "Custom Field 6", 146 "Custom Field 7", 147 "Custom Field 8", 148 "FRU File ID", 149 "Manufacturer", 150 "Name", 151 "Part Number", 152 "Serial Number", 153 "fault", 154 "fru_type", 155 "is_fru", 156 "present", 157 "version", 158 ], 159 160 "DIMM": [ 161 "Asset Tag", 162 "Custom Field 1", 163 "Custom Field 2", 164 "Custom Field 3", 165 "Custom Field 4", 166 "Custom Field 5", 167 "Custom Field 6", 168 "Custom Field 7", 169 "Custom Field 8", 170 "FRU File ID", 171 "Manufacturer", 172 "Model Number", 173 "Name", 174 "Serial Number", 175 "Version", 176 "fault", 177 "fru_type", 178 "is_fru", 179 "present", 180 "version", 181 ], 182 "MEMORY_BUFFER": [ 183 "Custom Field 1", 184 "Custom Field 2", 185 "Custom Field 3", 186 "Custom Field 4", 187 "Custom Field 5", 188 "Custom Field 6", 189 "Custom Field 7", 190 "Custom Field 8", 191 "FRU File ID", 192 "Manufacturer", 193 "Name", 194 "Part Number", 195 "Serial Number", 196 "fault", 197 "fru_type", 198 "is_fru", 199 "present", 200 "version", 201 ], 202 "FAN": [ 203 "fault", 204 "fru_type", 205 "is_fru", 206 "present", 207 "version", 208 ], 209 "DAUGHTER_CARD": [ 210 "Custom Field 1", 211 "Custom Field 2", 212 "Custom Field 3", 213 "Custom Field 4", 214 "Custom Field 5", 215 "Custom Field 6", 216 "Custom Field 7", 217 "Custom Field 8", 218 "FRU File ID", 219 "Manufacturer", 220 "Name", 221 "Part Number", 222 "Serial Number", 223 "fault", 224 "fru_type", 225 "is_fru", 226 "present", 227 "version", 228 ], 229 "BMC": [ 230 "fault", 231 "fru_type", 232 "is_fru", 233 "manufacturer", 234 "present", 235 "version", 236 ], 237 "MAIN_PLANAR": [ 238 "Custom Field 1", 239 "Custom Field 2", 240 "Custom Field 3", 241 "Custom Field 4", 242 "Custom Field 5", 243 "Custom Field 6", 244 "Custom Field 7", 245 "Custom Field 8", 246 "Part Number", 247 "Serial Number", 248 "Type", 249 "fault", 250 "fru_type", 251 "is_fru", 252 "present", 253 "version", 254 ], 255 "SYSTEM": [ 256 "Custom Field 1", 257 "Custom Field 2", 258 "Custom Field 3", 259 "Custom Field 4", 260 "Custom Field 5", 261 "Custom Field 6", 262 "Custom Field 7", 263 "Custom Field 8", 264 "FRU File ID", 265 "Manufacturer", 266 "Model Number", 267 "Name", 268 "Serial Number", 269 "Version", 270 "fault", 271 "fru_type", 272 "is_fru", 273 "present", 274 "version", 275 ], 276 "CORE": [ 277 "fault", 278 "fru_type", 279 "is_fru", 280 "present", 281 "version", 282 ], 283} 284