1# SPDX-License-Identifier: GPL-2.0+
2#
3# Copyright (C) 2018 Ravi Bangoria, IBM Corporation
4#
5# Hypervisor call statisics
6
7import os
8import sys
9
10sys.path.append(os.environ['PERF_EXEC_PATH'] + \
11	'/scripts/python/Perf-Trace-Util/lib/Perf/Trace')
12
13from perf_trace_context import *
14from Core import *
15from Util import *
16
17# output: {
18#	opcode: {
19#		'min': minimum time nsec
20#		'max': maximum time nsec
21#		'time': average time nsec
22#		'cnt': counter
23#	} ...
24# }
25output = {}
26
27# d_enter: {
28#	cpu: {
29#		opcode: nsec
30#	} ...
31# }
32d_enter = {}
33
34hcall_table = {
35	4: 'H_REMOVE',
36	8: 'H_ENTER',
37	12: 'H_READ',
38	16: 'H_CLEAR_MOD',
39	20: 'H_CLEAR_REF',
40	24: 'H_PROTECT',
41	28: 'H_GET_TCE',
42	32: 'H_PUT_TCE',
43	36: 'H_SET_SPRG0',
44	40: 'H_SET_DABR',
45	44: 'H_PAGE_INIT',
46	48: 'H_SET_ASR',
47	52: 'H_ASR_ON',
48	56: 'H_ASR_OFF',
49	60: 'H_LOGICAL_CI_LOAD',
50	64: 'H_LOGICAL_CI_STORE',
51	68: 'H_LOGICAL_CACHE_LOAD',
52	72: 'H_LOGICAL_CACHE_STORE',
53	76: 'H_LOGICAL_ICBI',
54	80: 'H_LOGICAL_DCBF',
55	84: 'H_GET_TERM_CHAR',
56	88: 'H_PUT_TERM_CHAR',
57	92: 'H_REAL_TO_LOGICAL',
58	96: 'H_HYPERVISOR_DATA',
59	100: 'H_EOI',
60	104: 'H_CPPR',
61	108: 'H_IPI',
62	112: 'H_IPOLL',
63	116: 'H_XIRR',
64	120: 'H_MIGRATE_DMA',
65	124: 'H_PERFMON',
66	220: 'H_REGISTER_VPA',
67	224: 'H_CEDE',
68	228: 'H_CONFER',
69	232: 'H_PROD',
70	236: 'H_GET_PPP',
71	240: 'H_SET_PPP',
72	244: 'H_PURR',
73	248: 'H_PIC',
74	252: 'H_REG_CRQ',
75	256: 'H_FREE_CRQ',
76	260: 'H_VIO_SIGNAL',
77	264: 'H_SEND_CRQ',
78	272: 'H_COPY_RDMA',
79	276: 'H_REGISTER_LOGICAL_LAN',
80	280: 'H_FREE_LOGICAL_LAN',
81	284: 'H_ADD_LOGICAL_LAN_BUFFER',
82	288: 'H_SEND_LOGICAL_LAN',
83	292: 'H_BULK_REMOVE',
84	304: 'H_MULTICAST_CTRL',
85	308: 'H_SET_XDABR',
86	312: 'H_STUFF_TCE',
87	316: 'H_PUT_TCE_INDIRECT',
88	332: 'H_CHANGE_LOGICAL_LAN_MAC',
89	336: 'H_VTERM_PARTNER_INFO',
90	340: 'H_REGISTER_VTERM',
91	344: 'H_FREE_VTERM',
92	348: 'H_RESET_EVENTS',
93	352: 'H_ALLOC_RESOURCE',
94	356: 'H_FREE_RESOURCE',
95	360: 'H_MODIFY_QP',
96	364: 'H_QUERY_QP',
97	368: 'H_REREGISTER_PMR',
98	372: 'H_REGISTER_SMR',
99	376: 'H_QUERY_MR',
100	380: 'H_QUERY_MW',
101	384: 'H_QUERY_HCA',
102	388: 'H_QUERY_PORT',
103	392: 'H_MODIFY_PORT',
104	396: 'H_DEFINE_AQP1',
105	400: 'H_GET_TRACE_BUFFER',
106	404: 'H_DEFINE_AQP0',
107	408: 'H_RESIZE_MR',
108	412: 'H_ATTACH_MCQP',
109	416: 'H_DETACH_MCQP',
110	420: 'H_CREATE_RPT',
111	424: 'H_REMOVE_RPT',
112	428: 'H_REGISTER_RPAGES',
113	432: 'H_DISABLE_AND_GETC',
114	436: 'H_ERROR_DATA',
115	440: 'H_GET_HCA_INFO',
116	444: 'H_GET_PERF_COUNT',
117	448: 'H_MANAGE_TRACE',
118	468: 'H_FREE_LOGICAL_LAN_BUFFER',
119	472: 'H_POLL_PENDING',
120	484: 'H_QUERY_INT_STATE',
121	580: 'H_ILLAN_ATTRIBUTES',
122	592: 'H_MODIFY_HEA_QP',
123	596: 'H_QUERY_HEA_QP',
124	600: 'H_QUERY_HEA',
125	604: 'H_QUERY_HEA_PORT',
126	608: 'H_MODIFY_HEA_PORT',
127	612: 'H_REG_BCMC',
128	616: 'H_DEREG_BCMC',
129	620: 'H_REGISTER_HEA_RPAGES',
130	624: 'H_DISABLE_AND_GET_HEA',
131	628: 'H_GET_HEA_INFO',
132	632: 'H_ALLOC_HEA_RESOURCE',
133	644: 'H_ADD_CONN',
134	648: 'H_DEL_CONN',
135	664: 'H_JOIN',
136	676: 'H_VASI_STATE',
137	688: 'H_ENABLE_CRQ',
138	696: 'H_GET_EM_PARMS',
139	720: 'H_SET_MPP',
140	724: 'H_GET_MPP',
141	748: 'H_HOME_NODE_ASSOCIATIVITY',
142	756: 'H_BEST_ENERGY',
143	764: 'H_XIRR_X',
144	768: 'H_RANDOM',
145	772: 'H_COP',
146	788: 'H_GET_MPP_X',
147	796: 'H_SET_MODE',
148	61440: 'H_RTAS',
149}
150
151def hcall_table_lookup(opcode):
152	if (hcall_table.has_key(opcode)):
153		return hcall_table[opcode]
154	else:
155		return opcode
156
157print_ptrn = '%-28s%10s%10s%10s%10s'
158
159def trace_end():
160	print print_ptrn % ('hcall', 'count', 'min(ns)', 'max(ns)', 'avg(ns)')
161	print '-' * 68
162	for opcode in output:
163		h_name = hcall_table_lookup(opcode)
164		time = output[opcode]['time']
165		cnt = output[opcode]['cnt']
166		min_t = output[opcode]['min']
167		max_t = output[opcode]['max']
168
169		print print_ptrn % (h_name, cnt, min_t, max_t, time/cnt)
170
171def powerpc__hcall_exit(name, context, cpu, sec, nsec, pid, comm, callchain,
172			opcode, retval):
173	if (d_enter.has_key(cpu) and d_enter[cpu].has_key(opcode)):
174		diff = nsecs(sec, nsec) - d_enter[cpu][opcode]
175
176		if (output.has_key(opcode)):
177			output[opcode]['time'] += diff
178			output[opcode]['cnt'] += 1
179			if (output[opcode]['min'] > diff):
180				output[opcode]['min'] = diff
181			if (output[opcode]['max'] < diff):
182				output[opcode]['max'] = diff
183		else:
184			output[opcode] = {
185				'time': diff,
186				'cnt': 1,
187				'min': diff,
188				'max': diff,
189			}
190
191		del d_enter[cpu][opcode]
192#	else:
193#		print "Can't find matching hcall_enter event. Ignoring sample"
194
195def powerpc__hcall_entry(event_name, context, cpu, sec, nsec, pid, comm,
196			 callchain, opcode):
197		if (d_enter.has_key(cpu)):
198			d_enter[cpu][opcode] = nsecs(sec, nsec)
199		else:
200			d_enter[cpu] = {opcode: nsecs(sec, nsec)}
201