xref: /openbmc/linux/include/xen/interface/xenpmu.h (revision 6d99a79c)
1 /* SPDX-License-Identifier: GPL-2.0 */
2 #ifndef __XEN_PUBLIC_XENPMU_H__
3 #define __XEN_PUBLIC_XENPMU_H__
4 
5 #include "xen.h"
6 
7 #define XENPMU_VER_MAJ    0
8 #define XENPMU_VER_MIN    1
9 
10 /*
11  * ` enum neg_errnoval
12  * ` HYPERVISOR_xenpmu_op(enum xenpmu_op cmd, struct xenpmu_params *args);
13  *
14  * @cmd  == XENPMU_* (PMU operation)
15  * @args == struct xenpmu_params
16  */
17 /* ` enum xenpmu_op { */
18 #define XENPMU_mode_get        0 /* Also used for getting PMU version */
19 #define XENPMU_mode_set        1
20 #define XENPMU_feature_get     2
21 #define XENPMU_feature_set     3
22 #define XENPMU_init            4
23 #define XENPMU_finish          5
24 #define XENPMU_lvtpc_set       6
25 #define XENPMU_flush           7
26 
27 /* ` } */
28 
29 /* Parameters structure for HYPERVISOR_xenpmu_op call */
30 struct xen_pmu_params {
31 	/* IN/OUT parameters */
32 	struct {
33 		uint32_t maj;
34 		uint32_t min;
35 	} version;
36 	uint64_t val;
37 
38 	/* IN parameters */
39 	uint32_t vcpu;
40 	uint32_t pad;
41 };
42 
43 /* PMU modes:
44  * - XENPMU_MODE_OFF:   No PMU virtualization
45  * - XENPMU_MODE_SELF:  Guests can profile themselves
46  * - XENPMU_MODE_HV:    Guests can profile themselves, dom0 profiles
47  *                      itself and Xen
48  * - XENPMU_MODE_ALL:   Only dom0 has access to VPMU and it profiles
49  *                      everyone: itself, the hypervisor and the guests.
50  */
51 #define XENPMU_MODE_OFF           0
52 #define XENPMU_MODE_SELF          (1<<0)
53 #define XENPMU_MODE_HV            (1<<1)
54 #define XENPMU_MODE_ALL           (1<<2)
55 
56 /*
57  * PMU features:
58  * - XENPMU_FEATURE_INTEL_BTS: Intel BTS support (ignored on AMD)
59  */
60 #define XENPMU_FEATURE_INTEL_BTS  1
61 
62 /*
63  * Shared PMU data between hypervisor and PV(H) domains.
64  *
65  * The hypervisor fills out this structure during PMU interrupt and sends an
66  * interrupt to appropriate VCPU.
67  * Architecture-independent fields of xen_pmu_data are WO for the hypervisor
68  * and RO for the guest but some fields in xen_pmu_arch can be writable
69  * by both the hypervisor and the guest (see arch-$arch/pmu.h).
70  */
71 struct xen_pmu_data {
72 	/* Interrupted VCPU */
73 	uint32_t vcpu_id;
74 
75 	/*
76 	 * Physical processor on which the interrupt occurred. On non-privileged
77 	 * guests set to vcpu_id;
78 	 */
79 	uint32_t pcpu_id;
80 
81 	/*
82 	 * Domain that was interrupted. On non-privileged guests set to
83 	 * DOMID_SELF.
84 	 * On privileged guests can be DOMID_SELF, DOMID_XEN, or, when in
85 	 * XENPMU_MODE_ALL mode, domain ID of another domain.
86 	 */
87 	domid_t  domain_id;
88 
89 	uint8_t pad[6];
90 
91 	/* Architecture-specific information */
92 	struct xen_pmu_arch pmu;
93 };
94 
95 #endif /* __XEN_PUBLIC_XENPMU_H__ */
96