xref: /openbmc/linux/include/linux/power_supply.h (revision 078a55fc)
1 /*
2  *  Universal power supply monitor class
3  *
4  *  Copyright © 2007  Anton Vorontsov <cbou@mail.ru>
5  *  Copyright © 2004  Szabolcs Gyurko
6  *  Copyright © 2003  Ian Molton <spyro@f2s.com>
7  *
8  *  Modified: 2004, Oct     Szabolcs Gyurko
9  *
10  *  You may use this code as per GPL version 2
11  */
12 
13 #ifndef __LINUX_POWER_SUPPLY_H__
14 #define __LINUX_POWER_SUPPLY_H__
15 
16 #include <linux/workqueue.h>
17 #include <linux/leds.h>
18 
19 struct device;
20 
21 /*
22  * All voltages, currents, charges, energies, time and temperatures in uV,
23  * µA, µAh, µWh, seconds and tenths of degree Celsius unless otherwise
24  * stated. It's driver's job to convert its raw values to units in which
25  * this class operates.
26  */
27 
28 /*
29  * For systems where the charger determines the maximum battery capacity
30  * the min and max fields should be used to present these values to user
31  * space. Unused/unknown fields will not appear in sysfs.
32  */
33 
34 enum {
35 	POWER_SUPPLY_STATUS_UNKNOWN = 0,
36 	POWER_SUPPLY_STATUS_CHARGING,
37 	POWER_SUPPLY_STATUS_DISCHARGING,
38 	POWER_SUPPLY_STATUS_NOT_CHARGING,
39 	POWER_SUPPLY_STATUS_FULL,
40 };
41 
42 enum {
43 	POWER_SUPPLY_CHARGE_TYPE_UNKNOWN = 0,
44 	POWER_SUPPLY_CHARGE_TYPE_NONE,
45 	POWER_SUPPLY_CHARGE_TYPE_TRICKLE,
46 	POWER_SUPPLY_CHARGE_TYPE_FAST,
47 };
48 
49 enum {
50 	POWER_SUPPLY_HEALTH_UNKNOWN = 0,
51 	POWER_SUPPLY_HEALTH_GOOD,
52 	POWER_SUPPLY_HEALTH_OVERHEAT,
53 	POWER_SUPPLY_HEALTH_DEAD,
54 	POWER_SUPPLY_HEALTH_OVERVOLTAGE,
55 	POWER_SUPPLY_HEALTH_UNSPEC_FAILURE,
56 	POWER_SUPPLY_HEALTH_COLD,
57 	POWER_SUPPLY_HEALTH_WATCHDOG_TIMER_EXPIRE,
58 	POWER_SUPPLY_HEALTH_SAFETY_TIMER_EXPIRE,
59 };
60 
61 enum {
62 	POWER_SUPPLY_TECHNOLOGY_UNKNOWN = 0,
63 	POWER_SUPPLY_TECHNOLOGY_NiMH,
64 	POWER_SUPPLY_TECHNOLOGY_LION,
65 	POWER_SUPPLY_TECHNOLOGY_LIPO,
66 	POWER_SUPPLY_TECHNOLOGY_LiFe,
67 	POWER_SUPPLY_TECHNOLOGY_NiCd,
68 	POWER_SUPPLY_TECHNOLOGY_LiMn,
69 };
70 
71 enum {
72 	POWER_SUPPLY_CAPACITY_LEVEL_UNKNOWN = 0,
73 	POWER_SUPPLY_CAPACITY_LEVEL_CRITICAL,
74 	POWER_SUPPLY_CAPACITY_LEVEL_LOW,
75 	POWER_SUPPLY_CAPACITY_LEVEL_NORMAL,
76 	POWER_SUPPLY_CAPACITY_LEVEL_HIGH,
77 	POWER_SUPPLY_CAPACITY_LEVEL_FULL,
78 };
79 
80 enum {
81 	POWER_SUPPLY_SCOPE_UNKNOWN = 0,
82 	POWER_SUPPLY_SCOPE_SYSTEM,
83 	POWER_SUPPLY_SCOPE_DEVICE,
84 };
85 
86 enum power_supply_property {
87 	/* Properties of type `int' */
88 	POWER_SUPPLY_PROP_STATUS = 0,
89 	POWER_SUPPLY_PROP_CHARGE_TYPE,
90 	POWER_SUPPLY_PROP_HEALTH,
91 	POWER_SUPPLY_PROP_PRESENT,
92 	POWER_SUPPLY_PROP_ONLINE,
93 	POWER_SUPPLY_PROP_AUTHENTIC,
94 	POWER_SUPPLY_PROP_TECHNOLOGY,
95 	POWER_SUPPLY_PROP_CYCLE_COUNT,
96 	POWER_SUPPLY_PROP_VOLTAGE_MAX,
97 	POWER_SUPPLY_PROP_VOLTAGE_MIN,
98 	POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
99 	POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN,
100 	POWER_SUPPLY_PROP_VOLTAGE_NOW,
101 	POWER_SUPPLY_PROP_VOLTAGE_AVG,
102 	POWER_SUPPLY_PROP_VOLTAGE_OCV,
103 	POWER_SUPPLY_PROP_CURRENT_MAX,
104 	POWER_SUPPLY_PROP_CURRENT_NOW,
105 	POWER_SUPPLY_PROP_CURRENT_AVG,
106 	POWER_SUPPLY_PROP_POWER_NOW,
107 	POWER_SUPPLY_PROP_POWER_AVG,
108 	POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
109 	POWER_SUPPLY_PROP_CHARGE_EMPTY_DESIGN,
110 	POWER_SUPPLY_PROP_CHARGE_FULL,
111 	POWER_SUPPLY_PROP_CHARGE_EMPTY,
112 	POWER_SUPPLY_PROP_CHARGE_NOW,
113 	POWER_SUPPLY_PROP_CHARGE_AVG,
114 	POWER_SUPPLY_PROP_CHARGE_COUNTER,
115 	POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT,
116 	POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX,
117 	POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
118 	POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX,
119 	POWER_SUPPLY_PROP_CHARGE_CONTROL_LIMIT,
120 	POWER_SUPPLY_PROP_CHARGE_CONTROL_LIMIT_MAX,
121 	POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN,
122 	POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN,
123 	POWER_SUPPLY_PROP_ENERGY_FULL,
124 	POWER_SUPPLY_PROP_ENERGY_EMPTY,
125 	POWER_SUPPLY_PROP_ENERGY_NOW,
126 	POWER_SUPPLY_PROP_ENERGY_AVG,
127 	POWER_SUPPLY_PROP_CAPACITY, /* in percents! */
128 	POWER_SUPPLY_PROP_CAPACITY_ALERT_MIN, /* in percents! */
129 	POWER_SUPPLY_PROP_CAPACITY_ALERT_MAX, /* in percents! */
130 	POWER_SUPPLY_PROP_CAPACITY_LEVEL,
131 	POWER_SUPPLY_PROP_TEMP,
132 	POWER_SUPPLY_PROP_TEMP_ALERT_MIN,
133 	POWER_SUPPLY_PROP_TEMP_ALERT_MAX,
134 	POWER_SUPPLY_PROP_TEMP_AMBIENT,
135 	POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MIN,
136 	POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MAX,
137 	POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW,
138 	POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG,
139 	POWER_SUPPLY_PROP_TIME_TO_FULL_NOW,
140 	POWER_SUPPLY_PROP_TIME_TO_FULL_AVG,
141 	POWER_SUPPLY_PROP_TYPE, /* use power_supply.type instead */
142 	POWER_SUPPLY_PROP_SCOPE,
143 	/* Properties of type `const char *' */
144 	POWER_SUPPLY_PROP_MODEL_NAME,
145 	POWER_SUPPLY_PROP_MANUFACTURER,
146 	POWER_SUPPLY_PROP_SERIAL_NUMBER,
147 };
148 
149 enum power_supply_type {
150 	POWER_SUPPLY_TYPE_UNKNOWN = 0,
151 	POWER_SUPPLY_TYPE_BATTERY,
152 	POWER_SUPPLY_TYPE_UPS,
153 	POWER_SUPPLY_TYPE_MAINS,
154 	POWER_SUPPLY_TYPE_USB,		/* Standard Downstream Port */
155 	POWER_SUPPLY_TYPE_USB_DCP,	/* Dedicated Charging Port */
156 	POWER_SUPPLY_TYPE_USB_CDP,	/* Charging Downstream Port */
157 	POWER_SUPPLY_TYPE_USB_ACA,	/* Accessory Charger Adapters */
158 };
159 
160 union power_supply_propval {
161 	int intval;
162 	const char *strval;
163 };
164 
165 struct device_node;
166 
167 struct power_supply {
168 	const char *name;
169 	enum power_supply_type type;
170 	enum power_supply_property *properties;
171 	size_t num_properties;
172 
173 	char **supplied_to;
174 	size_t num_supplicants;
175 
176 	char **supplied_from;
177 	size_t num_supplies;
178 	struct device_node *of_node;
179 
180 	int (*get_property)(struct power_supply *psy,
181 			    enum power_supply_property psp,
182 			    union power_supply_propval *val);
183 	int (*set_property)(struct power_supply *psy,
184 			    enum power_supply_property psp,
185 			    const union power_supply_propval *val);
186 	int (*property_is_writeable)(struct power_supply *psy,
187 				     enum power_supply_property psp);
188 	void (*external_power_changed)(struct power_supply *psy);
189 	void (*set_charged)(struct power_supply *psy);
190 
191 	/* For APM emulation, think legacy userspace. */
192 	int use_for_apm;
193 
194 	/* private */
195 	struct device *dev;
196 	struct work_struct changed_work;
197 #ifdef CONFIG_THERMAL
198 	struct thermal_zone_device *tzd;
199 	struct thermal_cooling_device *tcd;
200 #endif
201 
202 #ifdef CONFIG_LEDS_TRIGGERS
203 	struct led_trigger *charging_full_trig;
204 	char *charging_full_trig_name;
205 	struct led_trigger *charging_trig;
206 	char *charging_trig_name;
207 	struct led_trigger *full_trig;
208 	char *full_trig_name;
209 	struct led_trigger *online_trig;
210 	char *online_trig_name;
211 	struct led_trigger *charging_blink_full_solid_trig;
212 	char *charging_blink_full_solid_trig_name;
213 #endif
214 };
215 
216 /*
217  * This is recommended structure to specify static power supply parameters.
218  * Generic one, parametrizable for different power supplies. Power supply
219  * class itself does not use it, but that's what implementing most platform
220  * drivers, should try reuse for consistency.
221  */
222 
223 struct power_supply_info {
224 	const char *name;
225 	int technology;
226 	int voltage_max_design;
227 	int voltage_min_design;
228 	int charge_full_design;
229 	int charge_empty_design;
230 	int energy_full_design;
231 	int energy_empty_design;
232 	int use_for_apm;
233 };
234 
235 extern struct power_supply *power_supply_get_by_name(const char *name);
236 extern void power_supply_changed(struct power_supply *psy);
237 extern int power_supply_am_i_supplied(struct power_supply *psy);
238 extern int power_supply_set_battery_charged(struct power_supply *psy);
239 
240 #ifdef CONFIG_POWER_SUPPLY
241 extern int power_supply_is_system_supplied(void);
242 #else
243 static inline int power_supply_is_system_supplied(void) { return -ENOSYS; }
244 #endif
245 
246 extern int power_supply_register(struct device *parent,
247 				 struct power_supply *psy);
248 extern void power_supply_unregister(struct power_supply *psy);
249 extern int power_supply_powers(struct power_supply *psy, struct device *dev);
250 
251 /* For APM emulation, think legacy userspace. */
252 extern struct class *power_supply_class;
253 
254 static inline bool power_supply_is_amp_property(enum power_supply_property psp)
255 {
256 	switch (psp) {
257 	case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
258 	case POWER_SUPPLY_PROP_CHARGE_EMPTY_DESIGN:
259 	case POWER_SUPPLY_PROP_CHARGE_FULL:
260 	case POWER_SUPPLY_PROP_CHARGE_EMPTY:
261 	case POWER_SUPPLY_PROP_CHARGE_NOW:
262 	case POWER_SUPPLY_PROP_CHARGE_AVG:
263 	case POWER_SUPPLY_PROP_CHARGE_COUNTER:
264 	case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
265 	case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX:
266 	case POWER_SUPPLY_PROP_CURRENT_MAX:
267 	case POWER_SUPPLY_PROP_CURRENT_NOW:
268 	case POWER_SUPPLY_PROP_CURRENT_AVG:
269 		return 1;
270 	default:
271 		break;
272 	}
273 
274 	return 0;
275 }
276 
277 static inline bool power_supply_is_watt_property(enum power_supply_property psp)
278 {
279 	switch (psp) {
280 	case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN:
281 	case POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN:
282 	case POWER_SUPPLY_PROP_ENERGY_FULL:
283 	case POWER_SUPPLY_PROP_ENERGY_EMPTY:
284 	case POWER_SUPPLY_PROP_ENERGY_NOW:
285 	case POWER_SUPPLY_PROP_ENERGY_AVG:
286 	case POWER_SUPPLY_PROP_VOLTAGE_MAX:
287 	case POWER_SUPPLY_PROP_VOLTAGE_MIN:
288 	case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
289 	case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN:
290 	case POWER_SUPPLY_PROP_VOLTAGE_NOW:
291 	case POWER_SUPPLY_PROP_VOLTAGE_AVG:
292 	case POWER_SUPPLY_PROP_VOLTAGE_OCV:
293 	case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE:
294 	case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX:
295 	case POWER_SUPPLY_PROP_POWER_NOW:
296 		return 1;
297 	default:
298 		break;
299 	}
300 
301 	return 0;
302 }
303 
304 #endif /* __LINUX_POWER_SUPPLY_H__ */
305