xref: /openbmc/linux/fs/freevxfs/vxfs_inode.c (revision 0c6dfa75)
1 // SPDX-License-Identifier: GPL-2.0-only
2 /*
3  * Copyright (c) 2000-2001 Christoph Hellwig.
4  * Copyright (c) 2016 Krzysztof Blaszkowski
5  */
6 
7 /*
8  * Veritas filesystem driver - inode routines.
9  */
10 #include <linux/fs.h>
11 #include <linux/buffer_head.h>
12 #include <linux/pagemap.h>
13 #include <linux/kernel.h>
14 #include <linux/slab.h>
15 #include <linux/namei.h>
16 
17 #include "vxfs.h"
18 #include "vxfs_inode.h"
19 #include "vxfs_extern.h"
20 
21 
22 #ifdef DIAGNOSTIC
23 /*
24  * Dump inode contents (partially).
25  */
26 void
27 vxfs_dumpi(struct vxfs_inode_info *vip, ino_t ino)
28 {
29 	printk(KERN_DEBUG "\n\n");
30 	if (ino)
31 		printk(KERN_DEBUG "dumping vxfs inode %ld\n", ino);
32 	else
33 		printk(KERN_DEBUG "dumping unknown vxfs inode\n");
34 
35 	printk(KERN_DEBUG "---------------------------\n");
36 	printk(KERN_DEBUG "mode is %x\n", vip->vii_mode);
37 	printk(KERN_DEBUG "nlink:%u, uid:%u, gid:%u\n",
38 			vip->vii_nlink, vip->vii_uid, vip->vii_gid);
39 	printk(KERN_DEBUG "size:%Lx, blocks:%u\n",
40 			vip->vii_size, vip->vii_blocks);
41 	printk(KERN_DEBUG "orgtype:%u\n", vip->vii_orgtype);
42 }
43 #endif
44 
45 /**
46  * vxfs_transmod - mode for a VxFS inode
47  * @vip:	VxFS inode
48  *
49  * Description:
50  *  vxfs_transmod returns a Linux mode_t for a given
51  *  VxFS inode structure.
52  */
53 static __inline__ umode_t
54 vxfs_transmod(struct vxfs_inode_info *vip)
55 {
56 	umode_t			ret = vip->vii_mode & ~VXFS_TYPE_MASK;
57 
58 	if (VXFS_ISFIFO(vip))
59 		ret |= S_IFIFO;
60 	if (VXFS_ISCHR(vip))
61 		ret |= S_IFCHR;
62 	if (VXFS_ISDIR(vip))
63 		ret |= S_IFDIR;
64 	if (VXFS_ISBLK(vip))
65 		ret |= S_IFBLK;
66 	if (VXFS_ISLNK(vip))
67 		ret |= S_IFLNK;
68 	if (VXFS_ISREG(vip))
69 		ret |= S_IFREG;
70 	if (VXFS_ISSOC(vip))
71 		ret |= S_IFSOCK;
72 
73 	return (ret);
74 }
75 
76 static inline void dip2vip_cpy(struct vxfs_sb_info *sbi,
77 		struct vxfs_inode_info *vip, struct vxfs_dinode *dip)
78 {
79 	struct inode *inode = &vip->vfs_inode;
80 
81 	vip->vii_mode = fs32_to_cpu(sbi, dip->vdi_mode);
82 	vip->vii_nlink = fs32_to_cpu(sbi, dip->vdi_nlink);
83 	vip->vii_uid = fs32_to_cpu(sbi, dip->vdi_uid);
84 	vip->vii_gid = fs32_to_cpu(sbi, dip->vdi_gid);
85 	vip->vii_size = fs64_to_cpu(sbi, dip->vdi_size);
86 	vip->vii_atime = fs32_to_cpu(sbi, dip->vdi_atime);
87 	vip->vii_autime = fs32_to_cpu(sbi, dip->vdi_autime);
88 	vip->vii_mtime = fs32_to_cpu(sbi, dip->vdi_mtime);
89 	vip->vii_mutime = fs32_to_cpu(sbi, dip->vdi_mutime);
90 	vip->vii_ctime = fs32_to_cpu(sbi, dip->vdi_ctime);
91 	vip->vii_cutime = fs32_to_cpu(sbi, dip->vdi_cutime);
92 	vip->vii_orgtype = dip->vdi_orgtype;
93 
94 	vip->vii_blocks = fs32_to_cpu(sbi, dip->vdi_blocks);
95 	vip->vii_gen = fs32_to_cpu(sbi, dip->vdi_gen);
96 
97 	if (VXFS_ISDIR(vip))
98 		vip->vii_dotdot = fs32_to_cpu(sbi, dip->vdi_dotdot);
99 	else if (!VXFS_ISREG(vip) && !VXFS_ISLNK(vip))
100 		vip->vii_rdev = fs32_to_cpu(sbi, dip->vdi_rdev);
101 
102 	/* don't endian swap the fields that differ by orgtype */
103 	memcpy(&vip->vii_org, &dip->vdi_org, sizeof(vip->vii_org));
104 
105 	inode->i_mode = vxfs_transmod(vip);
106 	i_uid_write(inode, (uid_t)vip->vii_uid);
107 	i_gid_write(inode, (gid_t)vip->vii_gid);
108 
109 	set_nlink(inode, vip->vii_nlink);
110 	inode->i_size = vip->vii_size;
111 
112 	inode->i_atime.tv_sec = vip->vii_atime;
113 	inode_set_ctime(inode, vip->vii_ctime, 0);
114 	inode->i_mtime.tv_sec = vip->vii_mtime;
115 	inode->i_atime.tv_nsec = 0;
116 	inode->i_mtime.tv_nsec = 0;
117 
118 	inode->i_blocks = vip->vii_blocks;
119 	inode->i_generation = vip->vii_gen;
120 }
121 
122 /**
123  * vxfs_blkiget - find inode based on extent #
124  * @sbp:	superblock of the filesystem we search in
125  * @extent:	number of the extent to search
126  * @ino:	inode number to search
127  *
128  * Description:
129  *  vxfs_blkiget searches inode @ino in the filesystem described by
130  *  @sbp in the extent @extent.
131  *  Returns the matching VxFS inode on success, else a NULL pointer.
132  *
133  * NOTE:
134  *  While __vxfs_iget uses the pagecache vxfs_blkiget uses the
135  *  buffercache.  This function should not be used outside the
136  *  read_super() method, otherwise the data may be incoherent.
137  */
138 struct inode *
139 vxfs_blkiget(struct super_block *sbp, u_long extent, ino_t ino)
140 {
141 	struct buffer_head		*bp;
142 	struct inode			*inode;
143 	u_long				block, offset;
144 
145 	inode = new_inode(sbp);
146 	if (!inode)
147 		return NULL;
148 	inode->i_ino = get_next_ino();
149 
150 	block = extent + ((ino * VXFS_ISIZE) / sbp->s_blocksize);
151 	offset = ((ino % (sbp->s_blocksize / VXFS_ISIZE)) * VXFS_ISIZE);
152 	bp = sb_bread(sbp, block);
153 
154 	if (bp && buffer_mapped(bp)) {
155 		struct vxfs_inode_info	*vip = VXFS_INO(inode);
156 		struct vxfs_dinode	*dip;
157 
158 		dip = (struct vxfs_dinode *)(bp->b_data + offset);
159 		dip2vip_cpy(VXFS_SBI(sbp), vip, dip);
160 		vip->vfs_inode.i_mapping->a_ops = &vxfs_aops;
161 #ifdef DIAGNOSTIC
162 		vxfs_dumpi(vip, ino);
163 #endif
164 		brelse(bp);
165 		return inode;
166 	}
167 
168 	printk(KERN_WARNING "vxfs: unable to read block %ld\n", block);
169 	brelse(bp);
170 	iput(inode);
171 	return NULL;
172 }
173 
174 /**
175  * __vxfs_iget - generic find inode facility
176  * @ilistp:		inode list
177  * @vip:		VxFS inode to fill in
178  * @ino:		inode number
179  *
180  * Description:
181  *  Search the for inode number @ino in the filesystem
182  *  described by @sbp.  Use the specified inode table (@ilistp).
183  *  Returns the matching inode on success, else an error code.
184  */
185 static int
186 __vxfs_iget(struct inode *ilistp, struct vxfs_inode_info *vip, ino_t ino)
187 {
188 	struct page			*pp;
189 	u_long				offset;
190 
191 	offset = (ino % (PAGE_SIZE / VXFS_ISIZE)) * VXFS_ISIZE;
192 	pp = vxfs_get_page(ilistp->i_mapping, ino * VXFS_ISIZE / PAGE_SIZE);
193 
194 	if (!IS_ERR(pp)) {
195 		struct vxfs_dinode	*dip;
196 		caddr_t			kaddr = (char *)page_address(pp);
197 
198 		dip = (struct vxfs_dinode *)(kaddr + offset);
199 		dip2vip_cpy(VXFS_SBI(ilistp->i_sb), vip, dip);
200 		vip->vfs_inode.i_mapping->a_ops = &vxfs_aops;
201 #ifdef DIAGNOSTIC
202 		vxfs_dumpi(vip, ino);
203 #endif
204 		vxfs_put_page(pp);
205 		return 0;
206 	}
207 
208 	printk(KERN_WARNING "vxfs: error on page 0x%p for inode %ld\n",
209 		pp, (unsigned long)ino);
210 	return PTR_ERR(pp);
211 }
212 
213 /**
214  * vxfs_stiget - find inode using the structural inode list
215  * @sbp:	VFS superblock
216  * @ino:	inode #
217  *
218  * Description:
219  *  Find inode @ino in the filesystem described by @sbp using
220  *  the structural inode list.
221  *  Returns the matching inode on success, else a NULL pointer.
222  */
223 struct inode *
224 vxfs_stiget(struct super_block *sbp, ino_t ino)
225 {
226 	struct inode *inode;
227 	int error;
228 
229 	inode = new_inode(sbp);
230 	if (!inode)
231 		return NULL;
232 	inode->i_ino = get_next_ino();
233 
234 	error = __vxfs_iget(VXFS_SBI(sbp)->vsi_stilist, VXFS_INO(inode), ino);
235 	if (error) {
236 		iput(inode);
237 		return NULL;
238 	}
239 
240 	return inode;
241 }
242 
243 /**
244  * vxfs_iget - get an inode
245  * @sbp:	the superblock to get the inode for
246  * @ino:	the number of the inode to get
247  *
248  * Description:
249  *  vxfs_read_inode creates an inode, reads the disk inode for @ino and fills
250  *  in all relevant fields in the new inode.
251  */
252 struct inode *
253 vxfs_iget(struct super_block *sbp, ino_t ino)
254 {
255 	struct vxfs_inode_info		*vip;
256 	const struct address_space_operations	*aops;
257 	struct inode *ip;
258 	int error;
259 
260 	ip = iget_locked(sbp, ino);
261 	if (!ip)
262 		return ERR_PTR(-ENOMEM);
263 	if (!(ip->i_state & I_NEW))
264 		return ip;
265 
266 	vip = VXFS_INO(ip);
267 	error = __vxfs_iget(VXFS_SBI(sbp)->vsi_ilist, vip, ino);
268 	if (error) {
269 		iget_failed(ip);
270 		return ERR_PTR(error);
271 	}
272 
273 	if (VXFS_ISIMMED(vip))
274 		aops = &vxfs_immed_aops;
275 	else
276 		aops = &vxfs_aops;
277 
278 	if (S_ISREG(ip->i_mode)) {
279 		ip->i_fop = &generic_ro_fops;
280 		ip->i_mapping->a_ops = aops;
281 	} else if (S_ISDIR(ip->i_mode)) {
282 		ip->i_op = &vxfs_dir_inode_ops;
283 		ip->i_fop = &vxfs_dir_operations;
284 		ip->i_mapping->a_ops = aops;
285 	} else if (S_ISLNK(ip->i_mode)) {
286 		if (!VXFS_ISIMMED(vip)) {
287 			ip->i_op = &page_symlink_inode_operations;
288 			inode_nohighmem(ip);
289 			ip->i_mapping->a_ops = &vxfs_aops;
290 		} else {
291 			ip->i_op = &simple_symlink_inode_operations;
292 			ip->i_link = vip->vii_immed.vi_immed;
293 			nd_terminate_link(ip->i_link, ip->i_size,
294 					  sizeof(vip->vii_immed.vi_immed) - 1);
295 		}
296 	} else
297 		init_special_inode(ip, ip->i_mode, old_decode_dev(vip->vii_rdev));
298 
299 	unlock_new_inode(ip);
300 	return ip;
301 }
302 
303 /**
304  * vxfs_evict_inode - remove inode from main memory
305  * @ip:		inode to discard.
306  *
307  * Description:
308  *  vxfs_evict_inode() is called on the final iput and frees the private
309  *  inode area.
310  */
311 void
312 vxfs_evict_inode(struct inode *ip)
313 {
314 	truncate_inode_pages_final(&ip->i_data);
315 	clear_inode(ip);
316 }
317