xref: /openbmc/linux/drivers/thermal/Kconfig (revision 8730046c)
1#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
6	tristate "Generic Thermal sysfs driver"
7	help
8	  Generic Thermal Sysfs driver offers a generic mechanism for
9	  thermal management. Usually it's made up of one or more thermal
10	  zone and cooling device.
11	  Each thermal zone contains its own temperature, trip points,
12	  cooling devices.
13	  All platforms with ACPI thermal support can use this driver.
14	  If you want this support, you should say Y or M here.
15
16if THERMAL
17
18config THERMAL_HWMON
19	bool
20	prompt "Expose thermal sensors as hwmon device"
21	depends on HWMON=y || HWMON=THERMAL
22	default y
23	help
24	  In case a sensor is registered with the thermal
25	  framework, this option will also register it
26	  as a hwmon. The sensor will then have the common
27	  hwmon sysfs interface.
28
29	  Say 'Y' here if you want all thermal sensors to
30	  have hwmon sysfs interface too.
31
32config THERMAL_OF
33	bool
34	prompt "APIs to parse thermal data out of device tree"
35	depends on OF
36	default y
37	help
38	  This options provides helpers to add the support to
39	  read and parse thermal data definitions out of the
40	  device tree blob.
41
42	  Say 'Y' here if you need to build thermal infrastructure
43	  based on device tree.
44
45config THERMAL_WRITABLE_TRIPS
46	bool "Enable writable trip points"
47	help
48	  This option allows the system integrator to choose whether
49	  trip temperatures can be changed from userspace. The
50	  writable trips need to be specified when setting up the
51	  thermal zone but the choice here takes precedence.
52
53	  Say 'Y' here if you would like to allow userspace tools to
54	  change trip temperatures.
55
56choice
57	prompt "Default Thermal governor"
58	default THERMAL_DEFAULT_GOV_STEP_WISE
59	help
60	  This option sets which thermal governor shall be loaded at
61	  startup. If in doubt, select 'step_wise'.
62
63config THERMAL_DEFAULT_GOV_STEP_WISE
64	bool "step_wise"
65	select THERMAL_GOV_STEP_WISE
66	help
67	  Use the step_wise governor as default. This throttles the
68	  devices one step at a time.
69
70config THERMAL_DEFAULT_GOV_FAIR_SHARE
71	bool "fair_share"
72	select THERMAL_GOV_FAIR_SHARE
73	help
74	  Use the fair_share governor as default. This throttles the
75	  devices based on their 'contribution' to a zone. The
76	  contribution should be provided through platform data.
77
78config THERMAL_DEFAULT_GOV_USER_SPACE
79	bool "user_space"
80	select THERMAL_GOV_USER_SPACE
81	help
82	  Select this if you want to let the user space manage the
83	  platform thermals.
84
85config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
86	bool "power_allocator"
87	select THERMAL_GOV_POWER_ALLOCATOR
88	help
89	  Select this if you want to control temperature based on
90	  system and device power allocation. This governor can only
91	  operate on cooling devices that implement the power API.
92
93endchoice
94
95config THERMAL_GOV_FAIR_SHARE
96	bool "Fair-share thermal governor"
97	help
98	  Enable this to manage platform thermals using fair-share governor.
99
100config THERMAL_GOV_STEP_WISE
101	bool "Step_wise thermal governor"
102	help
103	  Enable this to manage platform thermals using a simple linear
104	  governor.
105
106config THERMAL_GOV_BANG_BANG
107	bool "Bang Bang thermal governor"
108	default n
109	help
110	  Enable this to manage platform thermals using bang bang governor.
111
112	  Say 'Y' here if you want to use two point temperature regulation
113	  used for fans without throttling.  Some fan drivers depend on this
114	  governor to be enabled (e.g. acerhdf).
115
116config THERMAL_GOV_USER_SPACE
117	bool "User_space thermal governor"
118	help
119	  Enable this to let the user space manage the platform thermals.
120
121config THERMAL_GOV_POWER_ALLOCATOR
122	bool "Power allocator thermal governor"
123	help
124	  Enable this to manage platform thermals by dynamically
125	  allocating and limiting power to devices.
126
127config CPU_THERMAL
128	bool "generic cpu cooling support"
129	depends on CPU_FREQ
130	depends on THERMAL_OF
131	help
132	  This implements the generic cpu cooling mechanism through frequency
133	  reduction. An ACPI version of this already exists
134	  (drivers/acpi/processor_thermal.c).
135	  This will be useful for platforms using the generic thermal interface
136	  and not the ACPI interface.
137
138	  If you want this support, you should say Y here.
139
140config CLOCK_THERMAL
141	bool "Generic clock cooling support"
142	depends on COMMON_CLK
143	depends on PM_OPP
144	help
145	  This entry implements the generic clock cooling mechanism through
146	  frequency clipping. Typically used to cool off co-processors. The
147	  device that is configured to use this cooling mechanism will be
148	  controlled to reduce clock frequency whenever temperature is high.
149
150config DEVFREQ_THERMAL
151	bool "Generic device cooling support"
152	depends on PM_DEVFREQ
153	depends on PM_OPP
154	help
155	  This implements the generic devfreq cooling mechanism through
156	  frequency reduction for devices using devfreq.
157
158	  This will throttle the device by limiting the maximum allowed DVFS
159	  frequency corresponding to the cooling level.
160
161	  In order to use the power extensions of the cooling device,
162	  devfreq should use the simple_ondemand governor.
163
164	  If you want this support, you should say Y here.
165
166config THERMAL_EMULATION
167	bool "Thermal emulation mode support"
168	help
169	  Enable this option to make a emul_temp sysfs node in thermal zone
170	  directory to support temperature emulation. With emulation sysfs node,
171	  user can manually input temperature and test the different trip
172	  threshold behaviour for simulation purpose.
173
174	  WARNING: Be careful while enabling this option on production systems,
175	  because userland can easily disable the thermal policy by simply
176	  flooding this sysfs node with low temperature values.
177
178config HISI_THERMAL
179	tristate "Hisilicon thermal driver"
180	depends on ARCH_HISI || COMPILE_TEST
181	depends on HAS_IOMEM
182	depends on OF
183	default y
184	help
185	  Enable this to plug hisilicon's thermal sensor driver into the Linux
186	  thermal framework. cpufreq is used as the cooling device to throttle
187	  CPUs when the passive trip is crossed.
188
189config IMX_THERMAL
190	tristate "Temperature sensor driver for Freescale i.MX SoCs"
191	depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
192	depends on MFD_SYSCON
193	depends on OF
194	help
195	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
196	  It supports one critical trip point and one passive trip point.  The
197	  cpufreq is used as the cooling device to throttle CPUs when the
198	  passive trip is crossed.
199
200config MAX77620_THERMAL
201	tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
202	depends on MFD_MAX77620
203	depends on OF
204	help
205	  Support for die junction temperature warning alarm for Maxim
206	  Semiconductor PMIC MAX77620 device. Device generates two alarm
207	  interrupts when PMIC die temperature cross the threshold of
208	  120 degC and 140 degC.
209
210config QORIQ_THERMAL
211	tristate "QorIQ Thermal Monitoring Unit"
212	depends on THERMAL_OF
213	depends on HAS_IOMEM
214	help
215	  Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
216	  It supports one critical trip point and one passive trip point. The
217	  cpufreq is used as the cooling device to throttle CPUs when the
218	  passive trip is crossed.
219
220config SPEAR_THERMAL
221	tristate "SPEAr thermal sensor driver"
222	depends on PLAT_SPEAR || COMPILE_TEST
223	depends on HAS_IOMEM
224	depends on OF
225	help
226	  Enable this to plug the SPEAr thermal sensor driver into the Linux
227	  thermal framework.
228
229config ROCKCHIP_THERMAL
230	tristate "Rockchip thermal driver"
231	depends on ARCH_ROCKCHIP || COMPILE_TEST
232	depends on RESET_CONTROLLER
233	depends on HAS_IOMEM
234	help
235	  Rockchip thermal driver provides support for Temperature sensor
236	  ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
237	  trip point. Cpufreq is used as the cooling device and will throttle
238	  CPUs when the Temperature crosses the passive trip point.
239
240config RCAR_THERMAL
241	tristate "Renesas R-Car thermal driver"
242	depends on ARCH_RENESAS || COMPILE_TEST
243	depends on HAS_IOMEM
244	help
245	  Enable this to plug the R-Car thermal sensor driver into the Linux
246	  thermal framework.
247
248config KIRKWOOD_THERMAL
249	tristate "Temperature sensor on Marvell Kirkwood SoCs"
250	depends on MACH_KIRKWOOD || COMPILE_TEST
251	depends on HAS_IOMEM
252	depends on OF
253	help
254	  Support for the Kirkwood thermal sensor driver into the Linux thermal
255	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
256
257config DOVE_THERMAL
258	tristate "Temperature sensor on Marvell Dove SoCs"
259	depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
260	depends on HAS_IOMEM
261	depends on OF
262	help
263	  Support for the Dove thermal sensor driver in the Linux thermal
264	  framework.
265
266config DB8500_THERMAL
267	tristate "DB8500 thermal management"
268	depends on MFD_DB8500_PRCMU
269	default y
270	help
271	  Adds DB8500 thermal management implementation according to the thermal
272	  management framework. A thermal zone with several trip points will be
273	  created. Cooling devices can be bound to the trip points to cool this
274	  thermal zone if trip points reached.
275
276config ARMADA_THERMAL
277	tristate "Armada 370/XP thermal management"
278	depends on ARCH_MVEBU || COMPILE_TEST
279	depends on HAS_IOMEM
280	depends on OF
281	help
282	  Enable this option if you want to have support for thermal management
283	  controller present in Armada 370 and Armada XP SoC.
284
285config DB8500_CPUFREQ_COOLING
286	tristate "DB8500 cpufreq cooling"
287	depends on ARCH_U8500 || COMPILE_TEST
288	depends on HAS_IOMEM
289	depends on CPU_THERMAL
290	default y
291	help
292	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
293	  bound to thermal zone trip points. When a trip point reached, the
294	  bound cpufreq cooling device turns active to set CPU frequency low to
295	  cool down the CPU.
296
297config INTEL_POWERCLAMP
298	tristate "Intel PowerClamp idle injection driver"
299	depends on THERMAL
300	depends on X86
301	depends on CPU_SUP_INTEL
302	help
303	  Enable this to enable Intel PowerClamp idle injection driver. This
304	  enforce idle time which results in more package C-state residency. The
305	  user interface is exposed via generic thermal framework.
306
307config X86_PKG_TEMP_THERMAL
308	tristate "X86 package temperature thermal driver"
309	depends on X86_THERMAL_VECTOR
310	select THERMAL_GOV_USER_SPACE
311	select THERMAL_WRITABLE_TRIPS
312	default m
313	help
314	  Enable this to register CPU digital sensor for package temperature as
315	  thermal zone. Each package will have its own thermal zone. There are
316	  two trip points which can be set by user to get notifications via thermal
317	  notification methods.
318
319config INTEL_SOC_DTS_IOSF_CORE
320	tristate
321	depends on X86
322	select IOSF_MBI
323	help
324	  This is becoming a common feature for Intel SoCs to expose the additional
325	  digital temperature sensors (DTSs) using side band interface (IOSF). This
326	  implements the common set of helper functions to register, get temperature
327	  and get/set thresholds on DTSs.
328
329config INTEL_SOC_DTS_THERMAL
330	tristate "Intel SoCs DTS thermal driver"
331	depends on X86
332	select INTEL_SOC_DTS_IOSF_CORE
333	select THERMAL_WRITABLE_TRIPS
334	help
335	  Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
336	  temperature sensor (DTS). These SoCs have two additional DTSs in
337	  addition to DTSs on CPU cores. Each DTS will be registered as a
338	  thermal zone. There are two trip points. One of the trip point can
339	  be set by user mode programs to get notifications via Linux thermal
340	  notification methods.The other trip is a critical trip point, which
341	  was set by the driver based on the TJ MAX temperature.
342
343config INTEL_QUARK_DTS_THERMAL
344	tristate "Intel Quark DTS thermal driver"
345	depends on X86_INTEL_QUARK
346	help
347	  Enable this to register Intel Quark SoC (e.g. X1000) platform digital
348	  temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
349	  The DTS will be registered as a thermal zone. There are two trip points:
350	  hot & critical. The critical trip point default value is set by
351	  underlying BIOS/Firmware.
352
353menu "ACPI INT340X thermal drivers"
354source drivers/thermal/int340x_thermal/Kconfig
355endmenu
356
357config INTEL_BXT_PMIC_THERMAL
358	tristate "Intel Broxton PMIC thermal driver"
359	depends on X86 && INTEL_SOC_PMIC && REGMAP
360	help
361	  Select this driver for Intel Broxton PMIC with ADC channels monitoring
362	  system temperature measurements and alerts.
363	  This driver is used for monitoring the ADC channels of PMIC and handles
364	  the alert trip point interrupts and notifies the thermal framework with
365	  the trip point and temperature details of the zone.
366
367config INTEL_PCH_THERMAL
368	tristate "Intel PCH Thermal Reporting Driver"
369	depends on X86 && PCI
370	help
371	  Enable this to support thermal reporting on certain intel PCHs.
372	  Thermal reporting device will provide temperature reading,
373	  programmable trip points and other information.
374
375config MTK_THERMAL
376	tristate "Temperature sensor driver for mediatek SoCs"
377	depends on ARCH_MEDIATEK || COMPILE_TEST
378	depends on HAS_IOMEM
379	depends on NVMEM || NVMEM=n
380	depends on RESET_CONTROLLER
381	default y
382	help
383	  Enable this option if you want to have support for thermal management
384	  controller present in Mediatek SoCs
385
386menu "Texas Instruments thermal drivers"
387depends on ARCH_HAS_BANDGAP || COMPILE_TEST
388depends on HAS_IOMEM
389source "drivers/thermal/ti-soc-thermal/Kconfig"
390endmenu
391
392menu "Samsung thermal drivers"
393depends on ARCH_EXYNOS || COMPILE_TEST
394source "drivers/thermal/samsung/Kconfig"
395endmenu
396
397menu "STMicroelectronics thermal drivers"
398depends on ARCH_STI && OF
399source "drivers/thermal/st/Kconfig"
400endmenu
401
402config TANGO_THERMAL
403	tristate "Tango thermal management"
404	depends on ARCH_TANGO || COMPILE_TEST
405	help
406	  Enable the Tango thermal driver, which supports the primitive
407	  temperature sensor embedded in Tango chips since the SMP8758.
408	  This sensor only generates a 1-bit signal to indicate whether
409	  the die temperature exceeds a programmable threshold.
410
411source "drivers/thermal/tegra/Kconfig"
412
413config QCOM_SPMI_TEMP_ALARM
414	tristate "Qualcomm SPMI PMIC Temperature Alarm"
415	depends on OF && SPMI && IIO
416	select REGMAP_SPMI
417	help
418	  This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
419	  PMIC devices. It shows up in sysfs as a thermal sensor with multiple
420	  trip points. The temperature reported by the thermal sensor reflects the
421	  real time die temperature if an ADC is present or an estimate of the
422	  temperature based upon the over temperature stage value.
423
424config GENERIC_ADC_THERMAL
425	tristate "Generic ADC based thermal sensor"
426	depends on IIO
427	help
428	  This enabled a thermal sysfs driver for the temperature sensor
429	  which is connected to the General Purpose ADC. The ADC channel
430	  is read via IIO framework and the channel information is provided
431	  to this driver. This driver reports the temperature by reading ADC
432	  channel and converts it to temperature based on lookup table.
433
434menu "Qualcomm thermal drivers"
435depends on (ARCH_QCOM && OF) || COMPILE_TEST
436source "drivers/thermal/qcom/Kconfig"
437endmenu
438
439endif
440