xref: /openbmc/linux/drivers/thermal/Kconfig (revision 3805e6a1)
1#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
6	tristate "Generic Thermal sysfs driver"
7	help
8	  Generic Thermal Sysfs driver offers a generic mechanism for
9	  thermal management. Usually it's made up of one or more thermal
10	  zone and cooling device.
11	  Each thermal zone contains its own temperature, trip points,
12	  cooling devices.
13	  All platforms with ACPI thermal support can use this driver.
14	  If you want this support, you should say Y or M here.
15
16if THERMAL
17
18config THERMAL_HWMON
19	bool
20	prompt "Expose thermal sensors as hwmon device"
21	depends on HWMON=y || HWMON=THERMAL
22	default y
23	help
24	  In case a sensor is registered with the thermal
25	  framework, this option will also register it
26	  as a hwmon. The sensor will then have the common
27	  hwmon sysfs interface.
28
29	  Say 'Y' here if you want all thermal sensors to
30	  have hwmon sysfs interface too.
31
32config THERMAL_OF
33	bool
34	prompt "APIs to parse thermal data out of device tree"
35	depends on OF
36	default y
37	help
38	  This options provides helpers to add the support to
39	  read and parse thermal data definitions out of the
40	  device tree blob.
41
42	  Say 'Y' here if you need to build thermal infrastructure
43	  based on device tree.
44
45config THERMAL_WRITABLE_TRIPS
46	bool "Enable writable trip points"
47	help
48	  This option allows the system integrator to choose whether
49	  trip temperatures can be changed from userspace. The
50	  writable trips need to be specified when setting up the
51	  thermal zone but the choice here takes precedence.
52
53	  Say 'Y' here if you would like to allow userspace tools to
54	  change trip temperatures.
55
56choice
57	prompt "Default Thermal governor"
58	default THERMAL_DEFAULT_GOV_STEP_WISE
59	help
60	  This option sets which thermal governor shall be loaded at
61	  startup. If in doubt, select 'step_wise'.
62
63config THERMAL_DEFAULT_GOV_STEP_WISE
64	bool "step_wise"
65	select THERMAL_GOV_STEP_WISE
66	help
67	  Use the step_wise governor as default. This throttles the
68	  devices one step at a time.
69
70config THERMAL_DEFAULT_GOV_FAIR_SHARE
71	bool "fair_share"
72	select THERMAL_GOV_FAIR_SHARE
73	help
74	  Use the fair_share governor as default. This throttles the
75	  devices based on their 'contribution' to a zone. The
76	  contribution should be provided through platform data.
77
78config THERMAL_DEFAULT_GOV_USER_SPACE
79	bool "user_space"
80	select THERMAL_GOV_USER_SPACE
81	help
82	  Select this if you want to let the user space manage the
83	  platform thermals.
84
85config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
86	bool "power_allocator"
87	select THERMAL_GOV_POWER_ALLOCATOR
88	help
89	  Select this if you want to control temperature based on
90	  system and device power allocation. This governor can only
91	  operate on cooling devices that implement the power API.
92
93endchoice
94
95config THERMAL_GOV_FAIR_SHARE
96	bool "Fair-share thermal governor"
97	help
98	  Enable this to manage platform thermals using fair-share governor.
99
100config THERMAL_GOV_STEP_WISE
101	bool "Step_wise thermal governor"
102	help
103	  Enable this to manage platform thermals using a simple linear
104	  governor.
105
106config THERMAL_GOV_BANG_BANG
107	bool "Bang Bang thermal governor"
108	default n
109	help
110	  Enable this to manage platform thermals using bang bang governor.
111
112	  Say 'Y' here if you want to use two point temperature regulation
113	  used for fans without throttling.  Some fan drivers depend on this
114	  governor to be enabled (e.g. acerhdf).
115
116config THERMAL_GOV_USER_SPACE
117	bool "User_space thermal governor"
118	help
119	  Enable this to let the user space manage the platform thermals.
120
121config THERMAL_GOV_POWER_ALLOCATOR
122	bool "Power allocator thermal governor"
123	help
124	  Enable this to manage platform thermals by dynamically
125	  allocating and limiting power to devices.
126
127config CPU_THERMAL
128	bool "generic cpu cooling support"
129	depends on CPU_FREQ
130	depends on THERMAL_OF
131	help
132	  This implements the generic cpu cooling mechanism through frequency
133	  reduction. An ACPI version of this already exists
134	  (drivers/acpi/processor_thermal.c).
135	  This will be useful for platforms using the generic thermal interface
136	  and not the ACPI interface.
137
138	  If you want this support, you should say Y here.
139
140config CLOCK_THERMAL
141	bool "Generic clock cooling support"
142	depends on COMMON_CLK
143	depends on PM_OPP
144	help
145	  This entry implements the generic clock cooling mechanism through
146	  frequency clipping. Typically used to cool off co-processors. The
147	  device that is configured to use this cooling mechanism will be
148	  controlled to reduce clock frequency whenever temperature is high.
149
150config DEVFREQ_THERMAL
151	bool "Generic device cooling support"
152	depends on PM_DEVFREQ
153	depends on PM_OPP
154	help
155	  This implements the generic devfreq cooling mechanism through
156	  frequency reduction for devices using devfreq.
157
158	  This will throttle the device by limiting the maximum allowed DVFS
159	  frequency corresponding to the cooling level.
160
161	  In order to use the power extensions of the cooling device,
162	  devfreq should use the simple_ondemand governor.
163
164	  If you want this support, you should say Y here.
165
166config THERMAL_EMULATION
167	bool "Thermal emulation mode support"
168	help
169	  Enable this option to make a emul_temp sysfs node in thermal zone
170	  directory to support temperature emulation. With emulation sysfs node,
171	  user can manually input temperature and test the different trip
172	  threshold behaviour for simulation purpose.
173
174	  WARNING: Be careful while enabling this option on production systems,
175	  because userland can easily disable the thermal policy by simply
176	  flooding this sysfs node with low temperature values.
177
178config HISI_THERMAL
179	tristate "Hisilicon thermal driver"
180	depends on (ARCH_HISI && CPU_THERMAL && OF) || COMPILE_TEST
181	depends on HAS_IOMEM
182	help
183	  Enable this to plug hisilicon's thermal sensor driver into the Linux
184	  thermal framework. cpufreq is used as the cooling device to throttle
185	  CPUs when the passive trip is crossed.
186
187config IMX_THERMAL
188	tristate "Temperature sensor driver for Freescale i.MX SoCs"
189	depends on CPU_THERMAL
190	depends on MFD_SYSCON
191	depends on OF
192	help
193	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
194	  It supports one critical trip point and one passive trip point.  The
195	  cpufreq is used as the cooling device to throttle CPUs when the
196	  passive trip is crossed.
197
198config SPEAR_THERMAL
199	tristate "SPEAr thermal sensor driver"
200	depends on PLAT_SPEAR || COMPILE_TEST
201	depends on HAS_IOMEM
202	depends on OF
203	help
204	  Enable this to plug the SPEAr thermal sensor driver into the Linux
205	  thermal framework.
206
207config ROCKCHIP_THERMAL
208	tristate "Rockchip thermal driver"
209	depends on ARCH_ROCKCHIP || COMPILE_TEST
210	depends on RESET_CONTROLLER
211	depends on HAS_IOMEM
212	help
213	  Rockchip thermal driver provides support for Temperature sensor
214	  ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
215	  trip point. Cpufreq is used as the cooling device and will throttle
216	  CPUs when the Temperature crosses the passive trip point.
217
218config RCAR_THERMAL
219	tristate "Renesas R-Car thermal driver"
220	depends on ARCH_RENESAS || COMPILE_TEST
221	depends on HAS_IOMEM
222	help
223	  Enable this to plug the R-Car thermal sensor driver into the Linux
224	  thermal framework.
225
226config KIRKWOOD_THERMAL
227	tristate "Temperature sensor on Marvell Kirkwood SoCs"
228	depends on MACH_KIRKWOOD || COMPILE_TEST
229	depends on HAS_IOMEM
230	depends on OF
231	help
232	  Support for the Kirkwood thermal sensor driver into the Linux thermal
233	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
234
235config DOVE_THERMAL
236	tristate "Temperature sensor on Marvell Dove SoCs"
237	depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
238	depends on HAS_IOMEM
239	depends on OF
240	help
241	  Support for the Dove thermal sensor driver in the Linux thermal
242	  framework.
243
244config DB8500_THERMAL
245	tristate "DB8500 thermal management"
246	depends on MFD_DB8500_PRCMU
247	default y
248	help
249	  Adds DB8500 thermal management implementation according to the thermal
250	  management framework. A thermal zone with several trip points will be
251	  created. Cooling devices can be bound to the trip points to cool this
252	  thermal zone if trip points reached.
253
254config ARMADA_THERMAL
255	tristate "Armada 370/XP thermal management"
256	depends on ARCH_MVEBU || COMPILE_TEST
257	depends on HAS_IOMEM
258	depends on OF
259	help
260	  Enable this option if you want to have support for thermal management
261	  controller present in Armada 370 and Armada XP SoC.
262
263config DB8500_CPUFREQ_COOLING
264	tristate "DB8500 cpufreq cooling"
265	depends on ARCH_U8500 || COMPILE_TEST
266	depends on HAS_IOMEM
267	depends on CPU_THERMAL
268	default y
269	help
270	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
271	  bound to thermal zone trip points. When a trip point reached, the
272	  bound cpufreq cooling device turns active to set CPU frequency low to
273	  cool down the CPU.
274
275config INTEL_POWERCLAMP
276	tristate "Intel PowerClamp idle injection driver"
277	depends on THERMAL
278	depends on X86
279	depends on CPU_SUP_INTEL
280	help
281	  Enable this to enable Intel PowerClamp idle injection driver. This
282	  enforce idle time which results in more package C-state residency. The
283	  user interface is exposed via generic thermal framework.
284
285config X86_PKG_TEMP_THERMAL
286	tristate "X86 package temperature thermal driver"
287	depends on X86_THERMAL_VECTOR
288	select THERMAL_GOV_USER_SPACE
289	select THERMAL_WRITABLE_TRIPS
290	default m
291	help
292	  Enable this to register CPU digital sensor for package temperature as
293	  thermal zone. Each package will have its own thermal zone. There are
294	  two trip points which can be set by user to get notifications via thermal
295	  notification methods.
296
297config INTEL_SOC_DTS_IOSF_CORE
298	tristate
299	depends on X86
300	select IOSF_MBI
301	help
302	  This is becoming a common feature for Intel SoCs to expose the additional
303	  digital temperature sensors (DTSs) using side band interface (IOSF). This
304	  implements the common set of helper functions to register, get temperature
305	  and get/set thresholds on DTSs.
306
307config INTEL_SOC_DTS_THERMAL
308	tristate "Intel SoCs DTS thermal driver"
309	depends on X86
310	select INTEL_SOC_DTS_IOSF_CORE
311	select THERMAL_WRITABLE_TRIPS
312	help
313	  Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
314	  temperature sensor (DTS). These SoCs have two additional DTSs in
315	  addition to DTSs on CPU cores. Each DTS will be registered as a
316	  thermal zone. There are two trip points. One of the trip point can
317	  be set by user mode programs to get notifications via Linux thermal
318	  notification methods.The other trip is a critical trip point, which
319	  was set by the driver based on the TJ MAX temperature.
320
321config INTEL_QUARK_DTS_THERMAL
322	tristate "Intel Quark DTS thermal driver"
323	depends on X86_INTEL_QUARK
324	help
325	  Enable this to register Intel Quark SoC (e.g. X1000) platform digital
326	  temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
327	  The DTS will be registered as a thermal zone. There are two trip points:
328	  hot & critical. The critical trip point default value is set by
329	  underlying BIOS/Firmware.
330
331menu "ACPI INT340X thermal drivers"
332source drivers/thermal/int340x_thermal/Kconfig
333endmenu
334
335config INTEL_PCH_THERMAL
336	tristate "Intel PCH Thermal Reporting Driver"
337	depends on X86 && PCI
338	help
339	  Enable this to support thermal reporting on certain intel PCHs.
340	  Thermal reporting device will provide temperature reading,
341	  programmable trip points and other information.
342
343config MTK_THERMAL
344	tristate "Temperature sensor driver for mediatek SoCs"
345	depends on ARCH_MEDIATEK || COMPILE_TEST
346	depends on HAS_IOMEM
347	depends on NVMEM || NVMEM=n
348	depends on RESET_CONTROLLER
349	default y
350	help
351	  Enable this option if you want to have support for thermal management
352	  controller present in Mediatek SoCs
353
354menu "Texas Instruments thermal drivers"
355depends on ARCH_HAS_BANDGAP || COMPILE_TEST
356depends on HAS_IOMEM
357source "drivers/thermal/ti-soc-thermal/Kconfig"
358endmenu
359
360menu "Samsung thermal drivers"
361depends on ARCH_EXYNOS || COMPILE_TEST
362source "drivers/thermal/samsung/Kconfig"
363endmenu
364
365menu "STMicroelectronics thermal drivers"
366depends on ARCH_STI && OF
367source "drivers/thermal/st/Kconfig"
368endmenu
369
370config TANGO_THERMAL
371	tristate "Tango thermal management"
372	depends on ARCH_TANGO || COMPILE_TEST
373	help
374	  Enable the Tango thermal driver, which supports the primitive
375	  temperature sensor embedded in Tango chips since the SMP8758.
376	  This sensor only generates a 1-bit signal to indicate whether
377	  the die temperature exceeds a programmable threshold.
378
379source "drivers/thermal/tegra/Kconfig"
380
381config QCOM_SPMI_TEMP_ALARM
382	tristate "Qualcomm SPMI PMIC Temperature Alarm"
383	depends on OF && SPMI && IIO
384	select REGMAP_SPMI
385	help
386	  This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
387	  PMIC devices. It shows up in sysfs as a thermal sensor with multiple
388	  trip points. The temperature reported by the thermal sensor reflects the
389	  real time die temperature if an ADC is present or an estimate of the
390	  temperature based upon the over temperature stage value.
391
392config GENERIC_ADC_THERMAL
393	tristate "Generic ADC based thermal sensor"
394	depends on IIO
395	help
396	  This enabled a thermal sysfs driver for the temperature sensor
397	  which is connected to the General Purpose ADC. The ADC channel
398	  is read via IIO framework and the channel information is provided
399	  to this driver. This driver reports the temperature by reading ADC
400	  channel and converts it to temperature based on lookup table.
401
402endif
403