xref: /openbmc/linux/drivers/hwmon/sht3x.c (revision 4f6cce39)
1 /* Sensirion SHT3x-DIS humidity and temperature sensor driver.
2  * The SHT3x comes in many different versions, this driver is for the
3  * I2C version only.
4  *
5  * Copyright (C) 2016 Sensirion AG, Switzerland
6  * Author: David Frey <david.frey@sensirion.com>
7  * Author: Pascal Sachs <pascal.sachs@sensirion.com>
8  *
9  * This program is free software; you can redistribute it and/or modify
10  * it under the terms of the GNU General Public License as published by
11  * the Free Software Foundation; either version 2 of the License, or
12  * (at your option) any later version.
13  *
14  * This program is distributed in the hope that it will be useful,
15  * but WITHOUT ANY WARRANTY; without even the implied warranty of
16  * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
17  * GNU General Public License for more details.
18  *
19  */
20 
21 #include <asm/page.h>
22 #include <linux/crc8.h>
23 #include <linux/delay.h>
24 #include <linux/err.h>
25 #include <linux/hwmon.h>
26 #include <linux/hwmon-sysfs.h>
27 #include <linux/i2c.h>
28 #include <linux/init.h>
29 #include <linux/kernel.h>
30 #include <linux/module.h>
31 #include <linux/slab.h>
32 #include <linux/jiffies.h>
33 #include <linux/platform_data/sht3x.h>
34 
35 /* commands (high precision mode) */
36 static const unsigned char sht3x_cmd_measure_blocking_hpm[]    = { 0x2c, 0x06 };
37 static const unsigned char sht3x_cmd_measure_nonblocking_hpm[] = { 0x24, 0x00 };
38 
39 /* commands (low power mode) */
40 static const unsigned char sht3x_cmd_measure_blocking_lpm[]    = { 0x2c, 0x10 };
41 static const unsigned char sht3x_cmd_measure_nonblocking_lpm[] = { 0x24, 0x16 };
42 
43 /* commands for periodic mode */
44 static const unsigned char sht3x_cmd_measure_periodic_mode[]   = { 0xe0, 0x00 };
45 static const unsigned char sht3x_cmd_break[]                   = { 0x30, 0x93 };
46 
47 /* commands for heater control */
48 static const unsigned char sht3x_cmd_heater_on[]               = { 0x30, 0x6d };
49 static const unsigned char sht3x_cmd_heater_off[]              = { 0x30, 0x66 };
50 
51 /* other commands */
52 static const unsigned char sht3x_cmd_read_status_reg[]         = { 0xf3, 0x2d };
53 static const unsigned char sht3x_cmd_clear_status_reg[]        = { 0x30, 0x41 };
54 
55 /* delays for non-blocking i2c commands, both in us */
56 #define SHT3X_NONBLOCKING_WAIT_TIME_HPM  15000
57 #define SHT3X_NONBLOCKING_WAIT_TIME_LPM   4000
58 
59 #define SHT3X_WORD_LEN         2
60 #define SHT3X_CMD_LENGTH       2
61 #define SHT3X_CRC8_LEN         1
62 #define SHT3X_RESPONSE_LENGTH  6
63 #define SHT3X_CRC8_POLYNOMIAL  0x31
64 #define SHT3X_CRC8_INIT        0xFF
65 #define SHT3X_MIN_TEMPERATURE  -45000
66 #define SHT3X_MAX_TEMPERATURE  130000
67 #define SHT3X_MIN_HUMIDITY     0
68 #define SHT3X_MAX_HUMIDITY     100000
69 
70 enum sht3x_chips {
71 	sht3x,
72 	sts3x,
73 };
74 
75 enum sht3x_limits {
76 	limit_max = 0,
77 	limit_max_hyst,
78 	limit_min,
79 	limit_min_hyst,
80 };
81 
82 DECLARE_CRC8_TABLE(sht3x_crc8_table);
83 
84 /* periodic measure commands (high precision mode) */
85 static const char periodic_measure_commands_hpm[][SHT3X_CMD_LENGTH] = {
86 	/* 0.5 measurements per second */
87 	{0x20, 0x32},
88 	/* 1 measurements per second */
89 	{0x21, 0x30},
90 	/* 2 measurements per second */
91 	{0x22, 0x36},
92 	/* 4 measurements per second */
93 	{0x23, 0x34},
94 	/* 10 measurements per second */
95 	{0x27, 0x37},
96 };
97 
98 /* periodic measure commands (low power mode) */
99 static const char periodic_measure_commands_lpm[][SHT3X_CMD_LENGTH] = {
100 	/* 0.5 measurements per second */
101 	{0x20, 0x2f},
102 	/* 1 measurements per second */
103 	{0x21, 0x2d},
104 	/* 2 measurements per second */
105 	{0x22, 0x2b},
106 	/* 4 measurements per second */
107 	{0x23, 0x29},
108 	/* 10 measurements per second */
109 	{0x27, 0x2a},
110 };
111 
112 struct sht3x_limit_commands {
113 	const char read_command[SHT3X_CMD_LENGTH];
114 	const char write_command[SHT3X_CMD_LENGTH];
115 };
116 
117 static const struct sht3x_limit_commands limit_commands[] = {
118 	/* temp1_max, humidity1_max */
119 	[limit_max] = { {0xe1, 0x1f}, {0x61, 0x1d} },
120 	/* temp_1_max_hyst, humidity1_max_hyst */
121 	[limit_max_hyst] = { {0xe1, 0x14}, {0x61, 0x16} },
122 	/* temp1_min, humidity1_min */
123 	[limit_min] = { {0xe1, 0x02}, {0x61, 0x00} },
124 	/* temp_1_min_hyst, humidity1_min_hyst */
125 	[limit_min_hyst] = { {0xe1, 0x09}, {0x61, 0x0B} },
126 };
127 
128 #define SHT3X_NUM_LIMIT_CMD  ARRAY_SIZE(limit_commands)
129 
130 static const u16 mode_to_update_interval[] = {
131 	   0,
132 	2000,
133 	1000,
134 	 500,
135 	 250,
136 	 100,
137 };
138 
139 struct sht3x_data {
140 	struct i2c_client *client;
141 	struct mutex i2c_lock; /* lock for sending i2c commands */
142 	struct mutex data_lock; /* lock for updating driver data */
143 
144 	u8 mode;
145 	const unsigned char *command;
146 	u32 wait_time;			/* in us*/
147 	unsigned long last_update;	/* last update in periodic mode*/
148 
149 	struct sht3x_platform_data setup;
150 
151 	/*
152 	 * cached values for temperature and humidity and limits
153 	 * the limits arrays have the following order:
154 	 * max, max_hyst, min, min_hyst
155 	 */
156 	int temperature;
157 	int temperature_limits[SHT3X_NUM_LIMIT_CMD];
158 	u32 humidity;
159 	u32 humidity_limits[SHT3X_NUM_LIMIT_CMD];
160 };
161 
162 static u8 get_mode_from_update_interval(u16 value)
163 {
164 	size_t index;
165 	u8 number_of_modes = ARRAY_SIZE(mode_to_update_interval);
166 
167 	if (value == 0)
168 		return 0;
169 
170 	/* find next faster update interval */
171 	for (index = 1; index < number_of_modes; index++) {
172 		if (mode_to_update_interval[index] <= value)
173 			return index;
174 	}
175 
176 	return number_of_modes - 1;
177 }
178 
179 static int sht3x_read_from_command(struct i2c_client *client,
180 				   struct sht3x_data *data,
181 				   const char *command,
182 				   char *buf, int length, u32 wait_time)
183 {
184 	int ret;
185 
186 	mutex_lock(&data->i2c_lock);
187 	ret = i2c_master_send(client, command, SHT3X_CMD_LENGTH);
188 
189 	if (ret != SHT3X_CMD_LENGTH) {
190 		ret = ret < 0 ? ret : -EIO;
191 		goto out;
192 	}
193 
194 	if (wait_time)
195 		usleep_range(wait_time, wait_time + 1000);
196 
197 	ret = i2c_master_recv(client, buf, length);
198 	if (ret != length) {
199 		ret = ret < 0 ? ret : -EIO;
200 		goto out;
201 	}
202 
203 	ret = 0;
204 out:
205 	mutex_unlock(&data->i2c_lock);
206 	return ret;
207 }
208 
209 static int sht3x_extract_temperature(u16 raw)
210 {
211 	/*
212 	 * From datasheet:
213 	 * T = -45 + 175 * ST / 2^16
214 	 * Adapted for integer fixed point (3 digit) arithmetic.
215 	 */
216 	return ((21875 * (int)raw) >> 13) - 45000;
217 }
218 
219 static u32 sht3x_extract_humidity(u16 raw)
220 {
221 	/*
222 	 * From datasheet:
223 	 * RH = 100 * SRH / 2^16
224 	 * Adapted for integer fixed point (3 digit) arithmetic.
225 	 */
226 	return (12500 * (u32)raw) >> 13;
227 }
228 
229 static struct sht3x_data *sht3x_update_client(struct device *dev)
230 {
231 	struct sht3x_data *data = dev_get_drvdata(dev);
232 	struct i2c_client *client = data->client;
233 	u16 interval_ms = mode_to_update_interval[data->mode];
234 	unsigned long interval_jiffies = msecs_to_jiffies(interval_ms);
235 	unsigned char buf[SHT3X_RESPONSE_LENGTH];
236 	u16 val;
237 	int ret = 0;
238 
239 	mutex_lock(&data->data_lock);
240 	/*
241 	 * Only update cached readings once per update interval in periodic
242 	 * mode. In single shot mode the sensor measures values on demand, so
243 	 * every time the sysfs interface is called, a measurement is triggered.
244 	 * In periodic mode however, the measurement process is handled
245 	 * internally by the sensor and reading out sensor values only makes
246 	 * sense if a new reading is available.
247 	 */
248 	if (time_after(jiffies, data->last_update + interval_jiffies)) {
249 		ret = sht3x_read_from_command(client, data, data->command, buf,
250 					      sizeof(buf), data->wait_time);
251 		if (ret)
252 			goto out;
253 
254 		val = be16_to_cpup((__be16 *)buf);
255 		data->temperature = sht3x_extract_temperature(val);
256 		val = be16_to_cpup((__be16 *)(buf + 3));
257 		data->humidity = sht3x_extract_humidity(val);
258 		data->last_update = jiffies;
259 	}
260 
261 out:
262 	mutex_unlock(&data->data_lock);
263 	if (ret)
264 		return ERR_PTR(ret);
265 
266 	return data;
267 }
268 
269 /* sysfs attributes */
270 static ssize_t temp1_input_show(struct device *dev,
271 				struct device_attribute *attr, char *buf)
272 {
273 	struct sht3x_data *data = sht3x_update_client(dev);
274 
275 	if (IS_ERR(data))
276 		return PTR_ERR(data);
277 
278 	return sprintf(buf, "%d\n", data->temperature);
279 }
280 
281 static ssize_t humidity1_input_show(struct device *dev,
282 				    struct device_attribute *attr, char *buf)
283 {
284 	struct sht3x_data *data = sht3x_update_client(dev);
285 
286 	if (IS_ERR(data))
287 		return PTR_ERR(data);
288 
289 	return sprintf(buf, "%u\n", data->humidity);
290 }
291 
292 /*
293  * limits_update must only be called from probe or with data_lock held
294  */
295 static int limits_update(struct sht3x_data *data)
296 {
297 	int ret;
298 	u8 index;
299 	int temperature;
300 	u32 humidity;
301 	u16 raw;
302 	char buffer[SHT3X_RESPONSE_LENGTH];
303 	const struct sht3x_limit_commands *commands;
304 	struct i2c_client *client = data->client;
305 
306 	for (index = 0; index < SHT3X_NUM_LIMIT_CMD; index++) {
307 		commands = &limit_commands[index];
308 		ret = sht3x_read_from_command(client, data,
309 					      commands->read_command, buffer,
310 					      SHT3X_RESPONSE_LENGTH, 0);
311 
312 		if (ret)
313 			return ret;
314 
315 		raw = be16_to_cpup((__be16 *)buffer);
316 		temperature = sht3x_extract_temperature((raw & 0x01ff) << 7);
317 		humidity = sht3x_extract_humidity(raw & 0xfe00);
318 		data->temperature_limits[index] = temperature;
319 		data->humidity_limits[index] = humidity;
320 	}
321 
322 	return ret;
323 }
324 
325 static ssize_t temp1_limit_show(struct device *dev,
326 				struct device_attribute *attr,
327 				char *buf)
328 {
329 	struct sht3x_data *data = dev_get_drvdata(dev);
330 	u8 index = to_sensor_dev_attr(attr)->index;
331 	int temperature_limit = data->temperature_limits[index];
332 
333 	return scnprintf(buf, PAGE_SIZE, "%d\n", temperature_limit);
334 }
335 
336 static ssize_t humidity1_limit_show(struct device *dev,
337 				    struct device_attribute *attr,
338 				    char *buf)
339 {
340 	struct sht3x_data *data = dev_get_drvdata(dev);
341 	u8 index = to_sensor_dev_attr(attr)->index;
342 	u32 humidity_limit = data->humidity_limits[index];
343 
344 	return scnprintf(buf, PAGE_SIZE, "%u\n", humidity_limit);
345 }
346 
347 /*
348  * limit_store must only be called with data_lock held
349  */
350 static size_t limit_store(struct device *dev,
351 			  size_t count,
352 			  u8 index,
353 			  int temperature,
354 			  u32 humidity)
355 {
356 	char buffer[SHT3X_CMD_LENGTH + SHT3X_WORD_LEN + SHT3X_CRC8_LEN];
357 	char *position = buffer;
358 	int ret;
359 	u16 raw;
360 	struct sht3x_data *data = dev_get_drvdata(dev);
361 	struct i2c_client *client = data->client;
362 	const struct sht3x_limit_commands *commands;
363 
364 	commands = &limit_commands[index];
365 
366 	memcpy(position, commands->write_command, SHT3X_CMD_LENGTH);
367 	position += SHT3X_CMD_LENGTH;
368 	/*
369 	 * ST = (T + 45) / 175 * 2^16
370 	 * SRH = RH / 100 * 2^16
371 	 * adapted for fixed point arithmetic and packed the same as
372 	 * in limit_show()
373 	 */
374 	raw = ((u32)(temperature + 45000) * 24543) >> (16 + 7);
375 	raw |= ((humidity * 42950) >> 16) & 0xfe00;
376 
377 	*((__be16 *)position) = cpu_to_be16(raw);
378 	position += SHT3X_WORD_LEN;
379 	*position = crc8(sht3x_crc8_table,
380 			 position - SHT3X_WORD_LEN,
381 			 SHT3X_WORD_LEN,
382 			 SHT3X_CRC8_INIT);
383 
384 	mutex_lock(&data->i2c_lock);
385 	ret = i2c_master_send(client, buffer, sizeof(buffer));
386 	mutex_unlock(&data->i2c_lock);
387 
388 	if (ret != sizeof(buffer))
389 		return ret < 0 ? ret : -EIO;
390 
391 	data->temperature_limits[index] = temperature;
392 	data->humidity_limits[index] = humidity;
393 	return count;
394 }
395 
396 static ssize_t temp1_limit_store(struct device *dev,
397 				 struct device_attribute *attr,
398 				 const char *buf,
399 				 size_t count)
400 {
401 	int temperature;
402 	int ret;
403 	struct sht3x_data *data = dev_get_drvdata(dev);
404 	u8 index = to_sensor_dev_attr(attr)->index;
405 
406 	ret = kstrtoint(buf, 0, &temperature);
407 	if (ret)
408 		return ret;
409 
410 	temperature = clamp_val(temperature, SHT3X_MIN_TEMPERATURE,
411 				SHT3X_MAX_TEMPERATURE);
412 	mutex_lock(&data->data_lock);
413 	ret = limit_store(dev, count, index, temperature,
414 			  data->humidity_limits[index]);
415 	mutex_unlock(&data->data_lock);
416 
417 	return ret;
418 }
419 
420 static ssize_t humidity1_limit_store(struct device *dev,
421 				     struct device_attribute *attr,
422 				     const char *buf,
423 				     size_t count)
424 {
425 	u32 humidity;
426 	int ret;
427 	struct sht3x_data *data = dev_get_drvdata(dev);
428 	u8 index = to_sensor_dev_attr(attr)->index;
429 
430 	ret = kstrtou32(buf, 0, &humidity);
431 	if (ret)
432 		return ret;
433 
434 	humidity = clamp_val(humidity, SHT3X_MIN_HUMIDITY, SHT3X_MAX_HUMIDITY);
435 	mutex_lock(&data->data_lock);
436 	ret = limit_store(dev, count, index, data->temperature_limits[index],
437 			  humidity);
438 	mutex_unlock(&data->data_lock);
439 
440 	return ret;
441 }
442 
443 static void sht3x_select_command(struct sht3x_data *data)
444 {
445 	/*
446 	 * In blocking mode (clock stretching mode) the I2C bus
447 	 * is blocked for other traffic, thus the call to i2c_master_recv()
448 	 * will wait until the data is ready. For non blocking mode, we
449 	 * have to wait ourselves.
450 	 */
451 	if (data->mode > 0) {
452 		data->command = sht3x_cmd_measure_periodic_mode;
453 		data->wait_time = 0;
454 	} else if (data->setup.blocking_io) {
455 		data->command = data->setup.high_precision ?
456 				sht3x_cmd_measure_blocking_hpm :
457 				sht3x_cmd_measure_blocking_lpm;
458 		data->wait_time = 0;
459 	} else {
460 		if (data->setup.high_precision) {
461 			data->command = sht3x_cmd_measure_nonblocking_hpm;
462 			data->wait_time = SHT3X_NONBLOCKING_WAIT_TIME_HPM;
463 		} else {
464 			data->command = sht3x_cmd_measure_nonblocking_lpm;
465 			data->wait_time = SHT3X_NONBLOCKING_WAIT_TIME_LPM;
466 		}
467 	}
468 }
469 
470 static int status_register_read(struct device *dev,
471 				struct device_attribute *attr,
472 				char *buffer, int length)
473 {
474 	int ret;
475 	struct sht3x_data *data = dev_get_drvdata(dev);
476 	struct i2c_client *client = data->client;
477 
478 	ret = sht3x_read_from_command(client, data, sht3x_cmd_read_status_reg,
479 				      buffer, length, 0);
480 
481 	return ret;
482 }
483 
484 static ssize_t temp1_alarm_show(struct device *dev,
485 				struct device_attribute *attr,
486 				char *buf)
487 {
488 	char buffer[SHT3X_WORD_LEN + SHT3X_CRC8_LEN];
489 	int ret;
490 
491 	ret = status_register_read(dev, attr, buffer,
492 				   SHT3X_WORD_LEN + SHT3X_CRC8_LEN);
493 	if (ret)
494 		return ret;
495 
496 	return scnprintf(buf, PAGE_SIZE, "%d\n", !!(buffer[0] & 0x04));
497 }
498 
499 static ssize_t humidity1_alarm_show(struct device *dev,
500 				    struct device_attribute *attr,
501 				    char *buf)
502 {
503 	char buffer[SHT3X_WORD_LEN + SHT3X_CRC8_LEN];
504 	int ret;
505 
506 	ret = status_register_read(dev, attr, buffer,
507 				   SHT3X_WORD_LEN + SHT3X_CRC8_LEN);
508 	if (ret)
509 		return ret;
510 
511 	return scnprintf(buf, PAGE_SIZE, "%d\n", !!(buffer[0] & 0x08));
512 }
513 
514 static ssize_t heater_enable_show(struct device *dev,
515 				  struct device_attribute *attr,
516 				  char *buf)
517 {
518 	char buffer[SHT3X_WORD_LEN + SHT3X_CRC8_LEN];
519 	int ret;
520 
521 	ret = status_register_read(dev, attr, buffer,
522 				   SHT3X_WORD_LEN + SHT3X_CRC8_LEN);
523 	if (ret)
524 		return ret;
525 
526 	return scnprintf(buf, PAGE_SIZE, "%d\n", !!(buffer[0] & 0x20));
527 }
528 
529 static ssize_t heater_enable_store(struct device *dev,
530 				   struct device_attribute *attr,
531 				   const char *buf,
532 				   size_t count)
533 {
534 	struct sht3x_data *data = dev_get_drvdata(dev);
535 	struct i2c_client *client = data->client;
536 	int ret;
537 	bool status;
538 
539 	ret = kstrtobool(buf, &status);
540 	if (ret)
541 		return ret;
542 
543 	mutex_lock(&data->i2c_lock);
544 
545 	if (status)
546 		ret = i2c_master_send(client, (char *)&sht3x_cmd_heater_on,
547 				      SHT3X_CMD_LENGTH);
548 	else
549 		ret = i2c_master_send(client, (char *)&sht3x_cmd_heater_off,
550 				      SHT3X_CMD_LENGTH);
551 
552 	mutex_unlock(&data->i2c_lock);
553 
554 	return ret;
555 }
556 
557 static ssize_t update_interval_show(struct device *dev,
558 				    struct device_attribute *attr,
559 				    char *buf)
560 {
561 	struct sht3x_data *data = dev_get_drvdata(dev);
562 
563 	return scnprintf(buf, PAGE_SIZE, "%u\n",
564 			 mode_to_update_interval[data->mode]);
565 }
566 
567 static ssize_t update_interval_store(struct device *dev,
568 				     struct device_attribute *attr,
569 				     const char *buf,
570 				     size_t count)
571 {
572 	u16 update_interval;
573 	u8 mode;
574 	int ret;
575 	const char *command;
576 	struct sht3x_data *data = dev_get_drvdata(dev);
577 	struct i2c_client *client = data->client;
578 
579 	ret = kstrtou16(buf, 0, &update_interval);
580 	if (ret)
581 		return ret;
582 
583 	mode = get_mode_from_update_interval(update_interval);
584 
585 	mutex_lock(&data->data_lock);
586 	/* mode did not change */
587 	if (mode == data->mode) {
588 		mutex_unlock(&data->data_lock);
589 		return count;
590 	}
591 
592 	mutex_lock(&data->i2c_lock);
593 	/*
594 	 * Abort periodic measure mode.
595 	 * To do any changes to the configuration while in periodic mode, we
596 	 * have to send a break command to the sensor, which then falls back
597 	 * to single shot (mode = 0).
598 	 */
599 	if (data->mode > 0) {
600 		ret = i2c_master_send(client, sht3x_cmd_break,
601 				      SHT3X_CMD_LENGTH);
602 		if (ret != SHT3X_CMD_LENGTH)
603 			goto out;
604 		data->mode = 0;
605 	}
606 
607 	if (mode > 0) {
608 		if (data->setup.high_precision)
609 			command = periodic_measure_commands_hpm[mode - 1];
610 		else
611 			command = periodic_measure_commands_lpm[mode - 1];
612 
613 		/* select mode */
614 		ret = i2c_master_send(client, command, SHT3X_CMD_LENGTH);
615 		if (ret != SHT3X_CMD_LENGTH)
616 			goto out;
617 	}
618 
619 	/* select mode and command */
620 	data->mode = mode;
621 	sht3x_select_command(data);
622 
623 out:
624 	mutex_unlock(&data->i2c_lock);
625 	mutex_unlock(&data->data_lock);
626 	if (ret != SHT3X_CMD_LENGTH)
627 		return ret < 0 ? ret : -EIO;
628 
629 	return count;
630 }
631 
632 static SENSOR_DEVICE_ATTR(temp1_input, S_IRUGO, temp1_input_show, NULL, 0);
633 static SENSOR_DEVICE_ATTR(humidity1_input, S_IRUGO, humidity1_input_show,
634 			  NULL, 0);
635 static SENSOR_DEVICE_ATTR(temp1_max, S_IRUGO | S_IWUSR,
636 			  temp1_limit_show, temp1_limit_store,
637 			  limit_max);
638 static SENSOR_DEVICE_ATTR(humidity1_max, S_IRUGO | S_IWUSR,
639 			  humidity1_limit_show, humidity1_limit_store,
640 			  limit_max);
641 static SENSOR_DEVICE_ATTR(temp1_max_hyst, S_IRUGO | S_IWUSR,
642 			  temp1_limit_show, temp1_limit_store,
643 			  limit_max_hyst);
644 static SENSOR_DEVICE_ATTR(humidity1_max_hyst, S_IRUGO | S_IWUSR,
645 			  humidity1_limit_show, humidity1_limit_store,
646 			  limit_max_hyst);
647 static SENSOR_DEVICE_ATTR(temp1_min, S_IRUGO | S_IWUSR,
648 			  temp1_limit_show, temp1_limit_store,
649 			  limit_min);
650 static SENSOR_DEVICE_ATTR(humidity1_min, S_IRUGO | S_IWUSR,
651 			  humidity1_limit_show, humidity1_limit_store,
652 			  limit_min);
653 static SENSOR_DEVICE_ATTR(temp1_min_hyst, S_IRUGO | S_IWUSR,
654 			  temp1_limit_show, temp1_limit_store,
655 			  limit_min_hyst);
656 static SENSOR_DEVICE_ATTR(humidity1_min_hyst, S_IRUGO | S_IWUSR,
657 			  humidity1_limit_show, humidity1_limit_store,
658 			  limit_min_hyst);
659 static SENSOR_DEVICE_ATTR(temp1_alarm, S_IRUGO, temp1_alarm_show, NULL, 0);
660 static SENSOR_DEVICE_ATTR(humidity1_alarm, S_IRUGO, humidity1_alarm_show,
661 			  NULL, 0);
662 static SENSOR_DEVICE_ATTR(heater_enable, S_IRUGO | S_IWUSR,
663 			  heater_enable_show, heater_enable_store, 0);
664 static SENSOR_DEVICE_ATTR(update_interval, S_IRUGO | S_IWUSR,
665 			  update_interval_show, update_interval_store, 0);
666 
667 static struct attribute *sht3x_attrs[] = {
668 	&sensor_dev_attr_temp1_input.dev_attr.attr,
669 	&sensor_dev_attr_humidity1_input.dev_attr.attr,
670 	&sensor_dev_attr_temp1_max.dev_attr.attr,
671 	&sensor_dev_attr_temp1_max_hyst.dev_attr.attr,
672 	&sensor_dev_attr_humidity1_max.dev_attr.attr,
673 	&sensor_dev_attr_humidity1_max_hyst.dev_attr.attr,
674 	&sensor_dev_attr_temp1_min.dev_attr.attr,
675 	&sensor_dev_attr_temp1_min_hyst.dev_attr.attr,
676 	&sensor_dev_attr_humidity1_min.dev_attr.attr,
677 	&sensor_dev_attr_humidity1_min_hyst.dev_attr.attr,
678 	&sensor_dev_attr_temp1_alarm.dev_attr.attr,
679 	&sensor_dev_attr_humidity1_alarm.dev_attr.attr,
680 	&sensor_dev_attr_heater_enable.dev_attr.attr,
681 	&sensor_dev_attr_update_interval.dev_attr.attr,
682 	NULL
683 };
684 
685 static struct attribute *sts3x_attrs[] = {
686 	&sensor_dev_attr_temp1_input.dev_attr.attr,
687 	NULL
688 };
689 
690 ATTRIBUTE_GROUPS(sht3x);
691 ATTRIBUTE_GROUPS(sts3x);
692 
693 static int sht3x_probe(struct i2c_client *client,
694 		       const struct i2c_device_id *id)
695 {
696 	int ret;
697 	struct sht3x_data *data;
698 	struct device *hwmon_dev;
699 	struct i2c_adapter *adap = client->adapter;
700 	struct device *dev = &client->dev;
701 	const struct attribute_group **attribute_groups;
702 
703 	/*
704 	 * we require full i2c support since the sht3x uses multi-byte read and
705 	 * writes as well as multi-byte commands which are not supported by
706 	 * the smbus protocol
707 	 */
708 	if (!i2c_check_functionality(adap, I2C_FUNC_I2C))
709 		return -ENODEV;
710 
711 	ret = i2c_master_send(client, sht3x_cmd_clear_status_reg,
712 			      SHT3X_CMD_LENGTH);
713 	if (ret != SHT3X_CMD_LENGTH)
714 		return ret < 0 ? ret : -ENODEV;
715 
716 	data = devm_kzalloc(dev, sizeof(*data), GFP_KERNEL);
717 	if (!data)
718 		return -ENOMEM;
719 
720 	data->setup.blocking_io = false;
721 	data->setup.high_precision = true;
722 	data->mode = 0;
723 	data->last_update = jiffies - msecs_to_jiffies(3000);
724 	data->client = client;
725 	crc8_populate_msb(sht3x_crc8_table, SHT3X_CRC8_POLYNOMIAL);
726 
727 	if (client->dev.platform_data)
728 		data->setup = *(struct sht3x_platform_data *)dev->platform_data;
729 
730 	sht3x_select_command(data);
731 
732 	mutex_init(&data->i2c_lock);
733 	mutex_init(&data->data_lock);
734 
735 	ret = limits_update(data);
736 	if (ret)
737 		return ret;
738 
739 	if (id->driver_data == sts3x)
740 		attribute_groups = sts3x_groups;
741 	else
742 		attribute_groups = sht3x_groups;
743 
744 	hwmon_dev = devm_hwmon_device_register_with_groups(dev,
745 							   client->name,
746 							   data,
747 							   attribute_groups);
748 
749 	if (IS_ERR(hwmon_dev))
750 		dev_dbg(dev, "unable to register hwmon device\n");
751 
752 	return PTR_ERR_OR_ZERO(hwmon_dev);
753 }
754 
755 /* device ID table */
756 static const struct i2c_device_id sht3x_ids[] = {
757 	{"sht3x", sht3x},
758 	{"sts3x", sts3x},
759 	{}
760 };
761 
762 MODULE_DEVICE_TABLE(i2c, sht3x_ids);
763 
764 static struct i2c_driver sht3x_i2c_driver = {
765 	.driver.name = "sht3x",
766 	.probe       = sht3x_probe,
767 	.id_table    = sht3x_ids,
768 };
769 
770 module_i2c_driver(sht3x_i2c_driver);
771 
772 MODULE_AUTHOR("David Frey <david.frey@sensirion.com>");
773 MODULE_AUTHOR("Pascal Sachs <pascal.sachs@sensirion.com>");
774 MODULE_DESCRIPTION("Sensirion SHT3x humidity and temperature sensor driver");
775 MODULE_LICENSE("GPL");