19d2ecfb7SGuenter Roeck# 29d2ecfb7SGuenter Roeck# PMBus chip drivers configuration 39d2ecfb7SGuenter Roeck# 49d2ecfb7SGuenter Roeck 59d2ecfb7SGuenter Roeckmenuconfig PMBUS 69d2ecfb7SGuenter Roeck tristate "PMBus support" 7f2bab3ebSKees Cook depends on I2C 89d2ecfb7SGuenter Roeck default n 99d2ecfb7SGuenter Roeck help 109d2ecfb7SGuenter Roeck Say yes here if you want to enable PMBus support. 119d2ecfb7SGuenter Roeck 129d2ecfb7SGuenter Roeck This driver can also be built as a module. If so, the module will 139d2ecfb7SGuenter Roeck be called pmbus_core. 149d2ecfb7SGuenter Roeck 159d2ecfb7SGuenter Roeckif PMBUS 169d2ecfb7SGuenter Roeck 179d2ecfb7SGuenter Roeckconfig SENSORS_PMBUS 189d2ecfb7SGuenter Roeck tristate "Generic PMBus devices" 199d2ecfb7SGuenter Roeck default y 209d2ecfb7SGuenter Roeck help 219d2ecfb7SGuenter Roeck If you say yes here you get hardware monitoring support for generic 22443830f6SGuenter Roeck PMBus devices, including but not limited to ADP4000, BMR453, BMR454, 23cfca3789SGuenter Roeck MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, TPS40400, TPS544B20, 24cfca3789SGuenter Roeck TPS544B25, TPS544C20, TPS544C25, and UDT020. 259d2ecfb7SGuenter Roeck 269d2ecfb7SGuenter Roeck This driver can also be built as a module. If so, the module will 279d2ecfb7SGuenter Roeck be called pmbus. 289d2ecfb7SGuenter Roeck 299d2ecfb7SGuenter Roeckconfig SENSORS_ADM1275 305cf231a3SGuenter Roeck tristate "Analog Devices ADM1275 and compatibles" 319d2ecfb7SGuenter Roeck default n 329d2ecfb7SGuenter Roeck help 339d2ecfb7SGuenter Roeck If you say yes here you get hardware monitoring support for Analog 34709066acSGuenter Roeck Devices ADM1075, ADM1275, ADM1276, ADM1278, ADM1293, and ADM1294 35709066acSGuenter Roeck Hot-Swap Controller and Digital Power Monitors. 369d2ecfb7SGuenter Roeck 379d2ecfb7SGuenter Roeck This driver can also be built as a module. If so, the module will 389d2ecfb7SGuenter Roeck be called adm1275. 399d2ecfb7SGuenter Roeck 40*f69316d6SEdward A. Jamesconfig SENSORS_IBM_CFFPS 41*f69316d6SEdward A. James tristate "IBM Common Form Factor Power Supply" 42*f69316d6SEdward A. James help 43*f69316d6SEdward A. James If you say yes here you get hardware monitoring support for the IBM 44*f69316d6SEdward A. James Common Form Factor power supply. 45*f69316d6SEdward A. James 46*f69316d6SEdward A. James This driver can also be built as a module. If so, the module will 47*f69316d6SEdward A. James be called ibm-cffps. 48*f69316d6SEdward A. James 498991ebd9SSamuel Mendoza-Jonasconfig SENSORS_IR35221 508991ebd9SSamuel Mendoza-Jonas tristate "Infineon IR35221" 518991ebd9SSamuel Mendoza-Jonas default n 528991ebd9SSamuel Mendoza-Jonas help 538991ebd9SSamuel Mendoza-Jonas If you say yes here you get hardware monitoring support for the 548991ebd9SSamuel Mendoza-Jonas Infineon IR35221 controller. 558991ebd9SSamuel Mendoza-Jonas 568991ebd9SSamuel Mendoza-Jonas This driver can also be built as a module. If so, the module will 578991ebd9SSamuel Mendoza-Jonas be called ir35521. 588991ebd9SSamuel Mendoza-Jonas 5903e9bd8dSGuenter Roeckconfig SENSORS_LM25066 6003e9bd8dSGuenter Roeck tristate "National Semiconductor LM25066 and compatibles" 6103e9bd8dSGuenter Roeck default n 6203e9bd8dSGuenter Roeck help 6303e9bd8dSGuenter Roeck If you say yes here you get hardware monitoring support for National 6458615a94SGuenter Roeck Semiconductor LM25056, LM25066, LM5064, and LM5066. 6503e9bd8dSGuenter Roeck 6603e9bd8dSGuenter Roeck This driver can also be built as a module. If so, the module will 6703e9bd8dSGuenter Roeck be called lm25066. 6803e9bd8dSGuenter Roeck 69c3ff9a67SGuenter Roeckconfig SENSORS_LTC2978 7077aa3585SAlan Tull tristate "Linear Technologies LTC2978 and compatibles" 71c3ff9a67SGuenter Roeck default n 72c3ff9a67SGuenter Roeck help 73c3ff9a67SGuenter Roeck If you say yes here you get hardware monitoring support for Linear 7452aae6afSGuenter Roeck Technology LTC2974, LTC2975, LTC2977, LTC2978, LTC2980, LTC3880, 75ccf2dc51SGuenter Roeck LTC3883, LTC3886, LTC3887, LTCM2987, LTM4675, and LTM4676. 76c3ff9a67SGuenter Roeck 77c3ff9a67SGuenter Roeck This driver can also be built as a module. If so, the module will 78c3ff9a67SGuenter Roeck be called ltc2978. 79c3ff9a67SGuenter Roeck 8077aa3585SAlan Tullconfig SENSORS_LTC2978_REGULATOR 816341e62bSChristoph Jaeger bool "Regulator support for LTC2978 and compatibles" 8277aa3585SAlan Tull depends on SENSORS_LTC2978 && REGULATOR 8377aa3585SAlan Tull help 8477aa3585SAlan Tull If you say yes here you get regulator support for Linear 8577aa3585SAlan Tull Technology LTC2974, LTC2977, LTC2978, LTC3880, LTC3883, and LTM4676. 8677aa3585SAlan Tull 878d28cd1bSGuenter Roeckconfig SENSORS_LTC3815 888d28cd1bSGuenter Roeck tristate "Linear Technologies LTC3815" 898d28cd1bSGuenter Roeck default n 908d28cd1bSGuenter Roeck help 918d28cd1bSGuenter Roeck If you say yes here you get hardware monitoring support for Linear 928d28cd1bSGuenter Roeck Technology LTC3815. 938d28cd1bSGuenter Roeck 948d28cd1bSGuenter Roeck This driver can also be built as a module. If so, the module will 958d28cd1bSGuenter Roeck be called ltc3815. 968d28cd1bSGuenter Roeck 979d2ecfb7SGuenter Roeckconfig SENSORS_MAX16064 989d2ecfb7SGuenter Roeck tristate "Maxim MAX16064" 999d2ecfb7SGuenter Roeck default n 1009d2ecfb7SGuenter Roeck help 1019d2ecfb7SGuenter Roeck If you say yes here you get hardware monitoring support for Maxim 1029d2ecfb7SGuenter Roeck MAX16064. 1039d2ecfb7SGuenter Roeck 1049d2ecfb7SGuenter Roeck This driver can also be built as a module. If so, the module will 1059d2ecfb7SGuenter Roeck be called max16064. 1069d2ecfb7SGuenter Roeck 1071f61cab8SGuenter Roeckconfig SENSORS_MAX20751 1081f61cab8SGuenter Roeck tristate "Maxim MAX20751" 1091f61cab8SGuenter Roeck default n 1101f61cab8SGuenter Roeck help 1111f61cab8SGuenter Roeck If you say yes here you get hardware monitoring support for Maxim 1121f61cab8SGuenter Roeck MAX20751. 1131f61cab8SGuenter Roeck 1141f61cab8SGuenter Roeck This driver can also be built as a module. If so, the module will 1151f61cab8SGuenter Roeck be called max20751. 1161f61cab8SGuenter Roeck 1179d2ecfb7SGuenter Roeckconfig SENSORS_MAX34440 118590defe5SGuenter Roeck tristate "Maxim MAX34440 and compatibles" 1199d2ecfb7SGuenter Roeck default n 1209d2ecfb7SGuenter Roeck help 1219d2ecfb7SGuenter Roeck If you say yes here you get hardware monitoring support for Maxim 12250115ac9SGuenter Roeck MAX34440, MAX34441, MAX34446, MAX34460, and MAX34461. 1239d2ecfb7SGuenter Roeck 1249d2ecfb7SGuenter Roeck This driver can also be built as a module. If so, the module will 1259d2ecfb7SGuenter Roeck be called max34440. 1269d2ecfb7SGuenter Roeck 1279d2ecfb7SGuenter Roeckconfig SENSORS_MAX8688 1289d2ecfb7SGuenter Roeck tristate "Maxim MAX8688" 1299d2ecfb7SGuenter Roeck default n 1309d2ecfb7SGuenter Roeck help 1319d2ecfb7SGuenter Roeck If you say yes here you get hardware monitoring support for Maxim 1329d2ecfb7SGuenter Roeck MAX8688. 1339d2ecfb7SGuenter Roeck 1349d2ecfb7SGuenter Roeck This driver can also be built as a module. If so, the module will 1359d2ecfb7SGuenter Roeck be called max8688. 1369d2ecfb7SGuenter Roeck 137a8bfecebSZhu, Richard \(NSN - CN/Beijing\)config SENSORS_TPS40422 138a8bfecebSZhu, Richard \(NSN - CN/Beijing\) tristate "TI TPS40422" 139a8bfecebSZhu, Richard \(NSN - CN/Beijing\) default n 140a8bfecebSZhu, Richard \(NSN - CN/Beijing\) help 141a8bfecebSZhu, Richard \(NSN - CN/Beijing\) If you say yes here you get hardware monitoring support for TI 142a8bfecebSZhu, Richard \(NSN - CN/Beijing\) TPS40422. 143a8bfecebSZhu, Richard \(NSN - CN/Beijing\) 144a8bfecebSZhu, Richard \(NSN - CN/Beijing\) This driver can also be built as a module. If so, the module will 145a8bfecebSZhu, Richard \(NSN - CN/Beijing\) be called tps40422. 146a8bfecebSZhu, Richard \(NSN - CN/Beijing\) 1479d2ecfb7SGuenter Roeckconfig SENSORS_UCD9000 14850b2b02cSMatt Weber tristate "TI UCD90120, UCD90124, UCD90160, UCD9090, UCD90910" 1499d2ecfb7SGuenter Roeck default n 1509d2ecfb7SGuenter Roeck help 1519d2ecfb7SGuenter Roeck If you say yes here you get hardware monitoring support for TI 15250b2b02cSMatt Weber UCD90120, UCD90124, UCD90160, UCD9090, UCD90910, Sequencer and System 15350b2b02cSMatt Weber Health Controllers. 1549d2ecfb7SGuenter Roeck 1559d2ecfb7SGuenter Roeck This driver can also be built as a module. If so, the module will 1569d2ecfb7SGuenter Roeck be called ucd9000. 1579d2ecfb7SGuenter Roeck 1589d2ecfb7SGuenter Roeckconfig SENSORS_UCD9200 1599d2ecfb7SGuenter Roeck tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248" 1609d2ecfb7SGuenter Roeck default n 1619d2ecfb7SGuenter Roeck help 1629d2ecfb7SGuenter Roeck If you say yes here you get hardware monitoring support for TI 1639d2ecfb7SGuenter Roeck UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248 1649d2ecfb7SGuenter Roeck Digital PWM System Controllers. 1659d2ecfb7SGuenter Roeck 1669d2ecfb7SGuenter Roeck This driver can also be built as a module. If so, the module will 1679d2ecfb7SGuenter Roeck be called ucd9200. 1689d2ecfb7SGuenter Roeck 169200855e5SGuenter Roeckconfig SENSORS_ZL6100 170200855e5SGuenter Roeck tristate "Intersil ZL6100 and compatibles" 171200855e5SGuenter Roeck default n 172200855e5SGuenter Roeck help 173200855e5SGuenter Roeck If you say yes here you get hardware monitoring support for Intersil 1743360a106SGuenter Roeck ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105, 1753360a106SGuenter Roeck ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for 1763360a106SGuenter Roeck Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464. 177200855e5SGuenter Roeck 178200855e5SGuenter Roeck This driver can also be built as a module. If so, the module will 179200855e5SGuenter Roeck be called zl6100. 180200855e5SGuenter Roeck 1819d2ecfb7SGuenter Roeckendif # PMBUS 182