xref: /openbmc/linux/drivers/hwmon/pmbus/Kconfig (revision 9158411b)
1ec8f24b7SThomas Gleixner# SPDX-License-Identifier: GPL-2.0-only
29d2ecfb7SGuenter Roeck#
39d2ecfb7SGuenter Roeck# PMBus chip drivers configuration
49d2ecfb7SGuenter Roeck#
59d2ecfb7SGuenter Roeck
69d2ecfb7SGuenter Roeckmenuconfig PMBUS
79d2ecfb7SGuenter Roeck	tristate "PMBus support"
8f2bab3ebSKees Cook	depends on I2C
99d2ecfb7SGuenter Roeck	help
109d2ecfb7SGuenter Roeck	  Say yes here if you want to enable PMBus support.
119d2ecfb7SGuenter Roeck
129d2ecfb7SGuenter Roeck	  This driver can also be built as a module. If so, the module will
139d2ecfb7SGuenter Roeck	  be called pmbus_core.
149d2ecfb7SGuenter Roeck
159d2ecfb7SGuenter Roeckif PMBUS
169d2ecfb7SGuenter Roeck
179d2ecfb7SGuenter Roeckconfig SENSORS_PMBUS
189d2ecfb7SGuenter Roeck	tristate "Generic PMBus devices"
199d2ecfb7SGuenter Roeck	default y
209d2ecfb7SGuenter Roeck	help
219d2ecfb7SGuenter Roeck	  If you say yes here you get hardware monitoring support for generic
22443830f6SGuenter Roeck	  PMBus devices, including but not limited to ADP4000, BMR453, BMR454,
23cfca3789SGuenter Roeck	  MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, TPS40400, TPS544B20,
24cfca3789SGuenter Roeck	  TPS544B25, TPS544C20, TPS544C25, and UDT020.
259d2ecfb7SGuenter Roeck
269d2ecfb7SGuenter Roeck	  This driver can also be built as a module. If so, the module will
279d2ecfb7SGuenter Roeck	  be called pmbus.
289d2ecfb7SGuenter Roeck
299d2ecfb7SGuenter Roeckconfig SENSORS_ADM1275
305cf231a3SGuenter Roeck	tristate "Analog Devices ADM1275 and compatibles"
319d2ecfb7SGuenter Roeck	help
329d2ecfb7SGuenter Roeck	  If you say yes here you get hardware monitoring support for Analog
334ff0ce22SGuenter Roeck	  Devices ADM1075, ADM1272, ADM1275, ADM1276, ADM1278, ADM1293,
344ff0ce22SGuenter Roeck	  and ADM1294 Hot-Swap Controller and Digital Power Monitors.
359d2ecfb7SGuenter Roeck
369d2ecfb7SGuenter Roeck	  This driver can also be built as a module. If so, the module will
379d2ecfb7SGuenter Roeck	  be called adm1275.
389d2ecfb7SGuenter Roeck
39f69316d6SEdward A. Jamesconfig SENSORS_IBM_CFFPS
40f69316d6SEdward A. James	tristate "IBM Common Form Factor Power Supply"
41b0076406SArnd Bergmann	depends on LEDS_CLASS
42f69316d6SEdward A. James	help
43f69316d6SEdward A. James	  If you say yes here you get hardware monitoring support for the IBM
44f69316d6SEdward A. James	  Common Form Factor power supply.
45f69316d6SEdward A. James
46f69316d6SEdward A. James	  This driver can also be built as a module. If so, the module will
47f69316d6SEdward A. James	  be called ibm-cffps.
48f69316d6SEdward A. James
498991ebd9SSamuel Mendoza-Jonasconfig SENSORS_IR35221
508991ebd9SSamuel Mendoza-Jonas	tristate "Infineon IR35221"
518991ebd9SSamuel Mendoza-Jonas	help
528991ebd9SSamuel Mendoza-Jonas	  If you say yes here you get hardware monitoring support for the
538991ebd9SSamuel Mendoza-Jonas	  Infineon IR35221 controller.
548991ebd9SSamuel Mendoza-Jonas
558991ebd9SSamuel Mendoza-Jonas	  This driver can also be built as a module. If so, the module will
568991ebd9SSamuel Mendoza-Jonas	  be called ir35521.
578991ebd9SSamuel Mendoza-Jonas
5800669d19SMaxim Sloykoconfig SENSORS_IR38064
5900669d19SMaxim Sloyko	tristate "Infineon IR38064"
6000669d19SMaxim Sloyko	help
6100669d19SMaxim Sloyko	  If you say yes here you get hardware monitoring support for Infineon
6200669d19SMaxim Sloyko	  IR38064.
6300669d19SMaxim Sloyko
6400669d19SMaxim Sloyko	  This driver can also be built as a module. If so, the module will
6500669d19SMaxim Sloyko	  be called ir38064.
6600669d19SMaxim Sloyko
67*9158411bSRobert Hancockconfig SENSORS_IRPS5401
68*9158411bSRobert Hancock	tristate "Infineon IRPS5401"
69*9158411bSRobert Hancock	help
70*9158411bSRobert Hancock	  If you say yes here you get hardware monitoring support for the
71*9158411bSRobert Hancock	  Infineon IRPS5401 controller.
72*9158411bSRobert Hancock
73*9158411bSRobert Hancock	  This driver can also be built as a module. If so, the module will
74*9158411bSRobert Hancock	  be called irps5401.
75*9158411bSRobert Hancock
76038a9c3dSMaxim Sloykoconfig SENSORS_ISL68137
77038a9c3dSMaxim Sloyko	tristate "Intersil ISL68137"
78038a9c3dSMaxim Sloyko	help
79038a9c3dSMaxim Sloyko	  If you say yes here you get hardware monitoring support for Intersil
80038a9c3dSMaxim Sloyko	  ISL68137.
81038a9c3dSMaxim Sloyko
82038a9c3dSMaxim Sloyko	  This driver can also be built as a module. If so, the module will
83038a9c3dSMaxim Sloyko	  be called isl68137.
84038a9c3dSMaxim Sloyko
8503e9bd8dSGuenter Roeckconfig SENSORS_LM25066
8603e9bd8dSGuenter Roeck	tristate "National Semiconductor LM25066 and compatibles"
8703e9bd8dSGuenter Roeck	help
8803e9bd8dSGuenter Roeck	  If you say yes here you get hardware monitoring support for National
8958615a94SGuenter Roeck	  Semiconductor LM25056, LM25066, LM5064, and LM5066.
9003e9bd8dSGuenter Roeck
9103e9bd8dSGuenter Roeck	  This driver can also be built as a module. If so, the module will
9203e9bd8dSGuenter Roeck	  be called lm25066.
9303e9bd8dSGuenter Roeck
94c3ff9a67SGuenter Roeckconfig SENSORS_LTC2978
9577aa3585SAlan Tull	tristate "Linear Technologies LTC2978 and compatibles"
96c3ff9a67SGuenter Roeck	help
97c3ff9a67SGuenter Roeck	  If you say yes here you get hardware monitoring support for Linear
9852aae6afSGuenter Roeck	  Technology LTC2974, LTC2975, LTC2977, LTC2978, LTC2980, LTC3880,
99ccf2dc51SGuenter Roeck	  LTC3883, LTC3886, LTC3887, LTCM2987, LTM4675, and LTM4676.
100c3ff9a67SGuenter Roeck
101c3ff9a67SGuenter Roeck	  This driver can also be built as a module. If so, the module will
102c3ff9a67SGuenter Roeck	  be called ltc2978.
103c3ff9a67SGuenter Roeck
10477aa3585SAlan Tullconfig SENSORS_LTC2978_REGULATOR
1056341e62bSChristoph Jaeger	bool "Regulator support for LTC2978 and compatibles"
10677aa3585SAlan Tull	depends on SENSORS_LTC2978 && REGULATOR
10777aa3585SAlan Tull	help
10877aa3585SAlan Tull	  If you say yes here you get regulator support for Linear
1094e15d05dSMichael Hennerich	  Technology LTC2974, LTC2977, LTC2978, LTC3880, LTC3883, LTM4676
1104e15d05dSMichael Hennerich	  and LTM4686.
11177aa3585SAlan Tull
1128d28cd1bSGuenter Roeckconfig SENSORS_LTC3815
1138d28cd1bSGuenter Roeck	tristate "Linear Technologies LTC3815"
1148d28cd1bSGuenter Roeck	help
1158d28cd1bSGuenter Roeck	  If you say yes here you get hardware monitoring support for Linear
1168d28cd1bSGuenter Roeck	  Technology LTC3815.
1178d28cd1bSGuenter Roeck
1188d28cd1bSGuenter Roeck	  This driver can also be built as a module. If so, the module will
1198d28cd1bSGuenter Roeck	  be called ltc3815.
1208d28cd1bSGuenter Roeck
1219d2ecfb7SGuenter Roeckconfig SENSORS_MAX16064
1229d2ecfb7SGuenter Roeck	tristate "Maxim MAX16064"
1239d2ecfb7SGuenter Roeck	help
1249d2ecfb7SGuenter Roeck	  If you say yes here you get hardware monitoring support for Maxim
1259d2ecfb7SGuenter Roeck	  MAX16064.
1269d2ecfb7SGuenter Roeck
1279d2ecfb7SGuenter Roeck	  This driver can also be built as a module. If so, the module will
1289d2ecfb7SGuenter Roeck	  be called max16064.
1299d2ecfb7SGuenter Roeck
1301f61cab8SGuenter Roeckconfig SENSORS_MAX20751
1311f61cab8SGuenter Roeck	tristate "Maxim MAX20751"
1321f61cab8SGuenter Roeck	help
1331f61cab8SGuenter Roeck	  If you say yes here you get hardware monitoring support for Maxim
1341f61cab8SGuenter Roeck	  MAX20751.
1351f61cab8SGuenter Roeck
1361f61cab8SGuenter Roeck	  This driver can also be built as a module. If so, the module will
1371f61cab8SGuenter Roeck	  be called max20751.
1381f61cab8SGuenter Roeck
1394d420a6aSAndrew Jefferyconfig SENSORS_MAX31785
1404d420a6aSAndrew Jeffery	tristate "Maxim MAX31785 and compatibles"
1414d420a6aSAndrew Jeffery	help
1424d420a6aSAndrew Jeffery	  If you say yes here you get hardware monitoring support for Maxim
1434d420a6aSAndrew Jeffery	  MAX31785.
1444d420a6aSAndrew Jeffery
1454d420a6aSAndrew Jeffery	  This driver can also be built as a module. If so, the module will
1464d420a6aSAndrew Jeffery	  be called max31785.
1474d420a6aSAndrew Jeffery
1489d2ecfb7SGuenter Roeckconfig SENSORS_MAX34440
149590defe5SGuenter Roeck	tristate "Maxim MAX34440 and compatibles"
1509d2ecfb7SGuenter Roeck	help
1519d2ecfb7SGuenter Roeck	  If you say yes here you get hardware monitoring support for Maxim
1527a001dbaSKun Yi	  MAX34440, MAX34441, MAX34446, MAX34451, MAX34460, and MAX34461.
1539d2ecfb7SGuenter Roeck
1549d2ecfb7SGuenter Roeck	  This driver can also be built as a module. If so, the module will
1559d2ecfb7SGuenter Roeck	  be called max34440.
1569d2ecfb7SGuenter Roeck
1579d2ecfb7SGuenter Roeckconfig SENSORS_MAX8688
1589d2ecfb7SGuenter Roeck	tristate "Maxim MAX8688"
1599d2ecfb7SGuenter Roeck	help
1609d2ecfb7SGuenter Roeck	  If you say yes here you get hardware monitoring support for Maxim
1619d2ecfb7SGuenter Roeck	  MAX8688.
1629d2ecfb7SGuenter Roeck
1639d2ecfb7SGuenter Roeck	  This driver can also be built as a module. If so, the module will
1649d2ecfb7SGuenter Roeck	  be called max8688.
1659d2ecfb7SGuenter Roeck
166344757baSVijay Khemkaconfig SENSORS_PXE1610
167344757baSVijay Khemka	tristate "Infineon PXE1610"
168344757baSVijay Khemka	help
169344757baSVijay Khemka	  If you say yes here you get hardware monitoring support for Infineon
170344757baSVijay Khemka	  PXE1610.
171344757baSVijay Khemka
172344757baSVijay Khemka	  This driver can also be built as a module. If so, the module will
173344757baSVijay Khemka	  be called pxe1610.
174344757baSVijay Khemka
175a8bfecebSZhu, Richard \(NSN - CN/Beijing\)config SENSORS_TPS40422
176a8bfecebSZhu, Richard \(NSN - CN/Beijing\)	tristate "TI TPS40422"
177a8bfecebSZhu, Richard \(NSN - CN/Beijing\)	help
178a8bfecebSZhu, Richard \(NSN - CN/Beijing\)	  If you say yes here you get hardware monitoring support for TI
179a8bfecebSZhu, Richard \(NSN - CN/Beijing\)	  TPS40422.
180a8bfecebSZhu, Richard \(NSN - CN/Beijing\)
181a8bfecebSZhu, Richard \(NSN - CN/Beijing\)	  This driver can also be built as a module. If so, the module will
182a8bfecebSZhu, Richard \(NSN - CN/Beijing\)	  be called tps40422.
183a8bfecebSZhu, Richard \(NSN - CN/Beijing\)
18461052652SVadim Pasternakconfig SENSORS_TPS53679
18561052652SVadim Pasternak	tristate "TI TPS53679"
18661052652SVadim Pasternak	help
18761052652SVadim Pasternak	  If you say yes here you get hardware monitoring support for TI
18861052652SVadim Pasternak	  TPS53679.
18961052652SVadim Pasternak
19061052652SVadim Pasternak	  This driver can also be built as a module. If so, the module will
19161052652SVadim Pasternak	  be called tps53679.
19261052652SVadim Pasternak
1939d2ecfb7SGuenter Roeckconfig SENSORS_UCD9000
19450b2b02cSMatt Weber	tristate "TI UCD90120, UCD90124, UCD90160, UCD9090, UCD90910"
1959d2ecfb7SGuenter Roeck	help
1969d2ecfb7SGuenter Roeck	  If you say yes here you get hardware monitoring support for TI
19750b2b02cSMatt Weber	  UCD90120, UCD90124, UCD90160, UCD9090, UCD90910, Sequencer and System
19850b2b02cSMatt Weber	  Health Controllers.
1999d2ecfb7SGuenter Roeck
2009d2ecfb7SGuenter Roeck	  This driver can also be built as a module. If so, the module will
2019d2ecfb7SGuenter Roeck	  be called ucd9000.
2029d2ecfb7SGuenter Roeck
2039d2ecfb7SGuenter Roeckconfig SENSORS_UCD9200
2049d2ecfb7SGuenter Roeck	tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
2059d2ecfb7SGuenter Roeck	help
2069d2ecfb7SGuenter Roeck	  If you say yes here you get hardware monitoring support for TI
2079d2ecfb7SGuenter Roeck	  UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
2089d2ecfb7SGuenter Roeck	  Digital PWM System Controllers.
2099d2ecfb7SGuenter Roeck
2109d2ecfb7SGuenter Roeck	  This driver can also be built as a module. If so, the module will
2119d2ecfb7SGuenter Roeck	  be called ucd9200.
2129d2ecfb7SGuenter Roeck
213200855e5SGuenter Roeckconfig SENSORS_ZL6100
214200855e5SGuenter Roeck	tristate "Intersil ZL6100 and compatibles"
215200855e5SGuenter Roeck	help
216200855e5SGuenter Roeck	  If you say yes here you get hardware monitoring support for Intersil
2173360a106SGuenter Roeck	  ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105,
2183360a106SGuenter Roeck	  ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for
2193360a106SGuenter Roeck	  Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464.
220200855e5SGuenter Roeck
221200855e5SGuenter Roeck	  This driver can also be built as a module. If so, the module will
222200855e5SGuenter Roeck	  be called zl6100.
223200855e5SGuenter Roeck
2249d2ecfb7SGuenter Roeckendif # PMBUS