xref: /openbmc/linux/drivers/gpu/drm/drm_cache.c (revision 4a075bd4)
1 /**************************************************************************
2  *
3  * Copyright (c) 2006-2007 Tungsten Graphics, Inc., Cedar Park, TX., USA
4  * All Rights Reserved.
5  *
6  * Permission is hereby granted, free of charge, to any person obtaining a
7  * copy of this software and associated documentation files (the
8  * "Software"), to deal in the Software without restriction, including
9  * without limitation the rights to use, copy, modify, merge, publish,
10  * distribute, sub license, and/or sell copies of the Software, and to
11  * permit persons to whom the Software is furnished to do so, subject to
12  * the following conditions:
13  *
14  * The above copyright notice and this permission notice (including the
15  * next paragraph) shall be included in all copies or substantial portions
16  * of the Software.
17  *
18  * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
19  * IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
20  * FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. IN NO EVENT SHALL
21  * THE COPYRIGHT HOLDERS, AUTHORS AND/OR ITS SUPPLIERS BE LIABLE FOR ANY CLAIM,
22  * DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR
23  * OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE
24  * USE OR OTHER DEALINGS IN THE SOFTWARE.
25  *
26  **************************************************************************/
27 /*
28  * Authors: Thomas Hellström <thomas-at-tungstengraphics-dot-com>
29  */
30 
31 #include <linux/export.h>
32 #include <linux/highmem.h>
33 
34 #include <drm/drm_cache.h>
35 
36 #if defined(CONFIG_X86)
37 #include <asm/smp.h>
38 
39 /*
40  * clflushopt is an unordered instruction which needs fencing with mfence or
41  * sfence to avoid ordering issues.  For drm_clflush_page this fencing happens
42  * in the caller.
43  */
44 static void
45 drm_clflush_page(struct page *page)
46 {
47 	uint8_t *page_virtual;
48 	unsigned int i;
49 	const int size = boot_cpu_data.x86_clflush_size;
50 
51 	if (unlikely(page == NULL))
52 		return;
53 
54 	page_virtual = kmap_atomic(page);
55 	for (i = 0; i < PAGE_SIZE; i += size)
56 		clflushopt(page_virtual + i);
57 	kunmap_atomic(page_virtual);
58 }
59 
60 static void drm_cache_flush_clflush(struct page *pages[],
61 				    unsigned long num_pages)
62 {
63 	unsigned long i;
64 
65 	mb();
66 	for (i = 0; i < num_pages; i++)
67 		drm_clflush_page(*pages++);
68 	mb();
69 }
70 #endif
71 
72 /**
73  * drm_clflush_pages - Flush dcache lines of a set of pages.
74  * @pages: List of pages to be flushed.
75  * @num_pages: Number of pages in the array.
76  *
77  * Flush every data cache line entry that points to an address belonging
78  * to a page in the array.
79  */
80 void
81 drm_clflush_pages(struct page *pages[], unsigned long num_pages)
82 {
83 
84 #if defined(CONFIG_X86)
85 	if (static_cpu_has(X86_FEATURE_CLFLUSH)) {
86 		drm_cache_flush_clflush(pages, num_pages);
87 		return;
88 	}
89 
90 	if (wbinvd_on_all_cpus())
91 		pr_err("Timed out waiting for cache flush\n");
92 
93 #elif defined(__powerpc__)
94 	unsigned long i;
95 	for (i = 0; i < num_pages; i++) {
96 		struct page *page = pages[i];
97 		void *page_virtual;
98 
99 		if (unlikely(page == NULL))
100 			continue;
101 
102 		page_virtual = kmap_atomic(page);
103 		flush_dcache_range((unsigned long)page_virtual,
104 				   (unsigned long)page_virtual + PAGE_SIZE);
105 		kunmap_atomic(page_virtual);
106 	}
107 #else
108 	pr_err("Architecture has no drm_cache.c support\n");
109 	WARN_ON_ONCE(1);
110 #endif
111 }
112 EXPORT_SYMBOL(drm_clflush_pages);
113 
114 /**
115  * drm_clflush_sg - Flush dcache lines pointing to a scather-gather.
116  * @st: struct sg_table.
117  *
118  * Flush every data cache line entry that points to an address in the
119  * sg.
120  */
121 void
122 drm_clflush_sg(struct sg_table *st)
123 {
124 #if defined(CONFIG_X86)
125 	if (static_cpu_has(X86_FEATURE_CLFLUSH)) {
126 		struct sg_page_iter sg_iter;
127 
128 		mb();
129 		for_each_sg_page(st->sgl, &sg_iter, st->nents, 0)
130 			drm_clflush_page(sg_page_iter_page(&sg_iter));
131 		mb();
132 
133 		return;
134 	}
135 
136 	if (wbinvd_on_all_cpus())
137 		pr_err("Timed out waiting for cache flush\n");
138 #else
139 	pr_err("Architecture has no drm_cache.c support\n");
140 	WARN_ON_ONCE(1);
141 #endif
142 }
143 EXPORT_SYMBOL(drm_clflush_sg);
144 
145 /**
146  * drm_clflush_virt_range - Flush dcache lines of a region
147  * @addr: Initial kernel memory address.
148  * @length: Region size.
149  *
150  * Flush every data cache line entry that points to an address in the
151  * region requested.
152  */
153 void
154 drm_clflush_virt_range(void *addr, unsigned long length)
155 {
156 #if defined(CONFIG_X86)
157 	if (static_cpu_has(X86_FEATURE_CLFLUSH)) {
158 		const int size = boot_cpu_data.x86_clflush_size;
159 		void *end = addr + length;
160 		addr = (void *)(((unsigned long)addr) & -size);
161 		mb();
162 		for (; addr < end; addr += size)
163 			clflushopt(addr);
164 		clflushopt(end - 1); /* force serialisation */
165 		mb();
166 		return;
167 	}
168 
169 	if (wbinvd_on_all_cpus())
170 		pr_err("Timed out waiting for cache flush\n");
171 #else
172 	pr_err("Architecture has no drm_cache.c support\n");
173 	WARN_ON_ONCE(1);
174 #endif
175 }
176 EXPORT_SYMBOL(drm_clflush_virt_range);
177