xref: /openbmc/linux/drivers/gpu/drm/drm_cache.c (revision 275876e2)
1 /**************************************************************************
2  *
3  * Copyright (c) 2006-2007 Tungsten Graphics, Inc., Cedar Park, TX., USA
4  * All Rights Reserved.
5  *
6  * Permission is hereby granted, free of charge, to any person obtaining a
7  * copy of this software and associated documentation files (the
8  * "Software"), to deal in the Software without restriction, including
9  * without limitation the rights to use, copy, modify, merge, publish,
10  * distribute, sub license, and/or sell copies of the Software, and to
11  * permit persons to whom the Software is furnished to do so, subject to
12  * the following conditions:
13  *
14  * The above copyright notice and this permission notice (including the
15  * next paragraph) shall be included in all copies or substantial portions
16  * of the Software.
17  *
18  * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
19  * IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
20  * FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. IN NO EVENT SHALL
21  * THE COPYRIGHT HOLDERS, AUTHORS AND/OR ITS SUPPLIERS BE LIABLE FOR ANY CLAIM,
22  * DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR
23  * OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE
24  * USE OR OTHER DEALINGS IN THE SOFTWARE.
25  *
26  **************************************************************************/
27 /*
28  * Authors: Thomas Hellström <thomas-at-tungstengraphics-dot-com>
29  */
30 
31 #include <linux/export.h>
32 #include <drm/drmP.h>
33 
34 #if defined(CONFIG_X86)
35 
36 /*
37  * clflushopt is an unordered instruction which needs fencing with mfence or
38  * sfence to avoid ordering issues.  For drm_clflush_page this fencing happens
39  * in the caller.
40  */
41 static void
42 drm_clflush_page(struct page *page)
43 {
44 	uint8_t *page_virtual;
45 	unsigned int i;
46 	const int size = boot_cpu_data.x86_clflush_size;
47 
48 	if (unlikely(page == NULL))
49 		return;
50 
51 	page_virtual = kmap_atomic(page);
52 	for (i = 0; i < PAGE_SIZE; i += size)
53 		clflushopt(page_virtual + i);
54 	kunmap_atomic(page_virtual);
55 }
56 
57 static void drm_cache_flush_clflush(struct page *pages[],
58 				    unsigned long num_pages)
59 {
60 	unsigned long i;
61 
62 	mb();
63 	for (i = 0; i < num_pages; i++)
64 		drm_clflush_page(*pages++);
65 	mb();
66 }
67 
68 static void
69 drm_clflush_ipi_handler(void *null)
70 {
71 	wbinvd();
72 }
73 #endif
74 
75 void
76 drm_clflush_pages(struct page *pages[], unsigned long num_pages)
77 {
78 
79 #if defined(CONFIG_X86)
80 	if (cpu_has_clflush) {
81 		drm_cache_flush_clflush(pages, num_pages);
82 		return;
83 	}
84 
85 	if (on_each_cpu(drm_clflush_ipi_handler, NULL, 1) != 0)
86 		printk(KERN_ERR "Timed out waiting for cache flush.\n");
87 
88 #elif defined(__powerpc__)
89 	unsigned long i;
90 	for (i = 0; i < num_pages; i++) {
91 		struct page *page = pages[i];
92 		void *page_virtual;
93 
94 		if (unlikely(page == NULL))
95 			continue;
96 
97 		page_virtual = kmap_atomic(page);
98 		flush_dcache_range((unsigned long)page_virtual,
99 				   (unsigned long)page_virtual + PAGE_SIZE);
100 		kunmap_atomic(page_virtual);
101 	}
102 #else
103 	printk(KERN_ERR "Architecture has no drm_cache.c support\n");
104 	WARN_ON_ONCE(1);
105 #endif
106 }
107 EXPORT_SYMBOL(drm_clflush_pages);
108 
109 void
110 drm_clflush_sg(struct sg_table *st)
111 {
112 #if defined(CONFIG_X86)
113 	if (cpu_has_clflush) {
114 		struct sg_page_iter sg_iter;
115 
116 		mb();
117 		for_each_sg_page(st->sgl, &sg_iter, st->nents, 0)
118 			drm_clflush_page(sg_page_iter_page(&sg_iter));
119 		mb();
120 
121 		return;
122 	}
123 
124 	if (on_each_cpu(drm_clflush_ipi_handler, NULL, 1) != 0)
125 		printk(KERN_ERR "Timed out waiting for cache flush.\n");
126 #else
127 	printk(KERN_ERR "Architecture has no drm_cache.c support\n");
128 	WARN_ON_ONCE(1);
129 #endif
130 }
131 EXPORT_SYMBOL(drm_clflush_sg);
132 
133 void
134 drm_clflush_virt_range(void *addr, unsigned long length)
135 {
136 #if defined(CONFIG_X86)
137 	if (cpu_has_clflush) {
138 		void *end = addr + length;
139 		mb();
140 		for (; addr < end; addr += boot_cpu_data.x86_clflush_size)
141 			clflushopt(addr);
142 		clflushopt(end - 1);
143 		mb();
144 		return;
145 	}
146 
147 	if (on_each_cpu(drm_clflush_ipi_handler, NULL, 1) != 0)
148 		printk(KERN_ERR "Timed out waiting for cache flush.\n");
149 #else
150 	printk(KERN_ERR "Architecture has no drm_cache.c support\n");
151 	WARN_ON_ONCE(1);
152 #endif
153 }
154 EXPORT_SYMBOL(drm_clflush_virt_range);
155