xref: /openbmc/linux/arch/riscv/mm/cacheflush.c (revision 2a954832)
1 // SPDX-License-Identifier: GPL-2.0-only
2 /*
3  * Copyright (C) 2017 SiFive
4  */
5 
6 #include <linux/of.h>
7 #include <asm/cacheflush.h>
8 
9 #ifdef CONFIG_SMP
10 
11 #include <asm/sbi.h>
12 
13 static void ipi_remote_fence_i(void *info)
14 {
15 	return local_flush_icache_all();
16 }
17 
18 void flush_icache_all(void)
19 {
20 	local_flush_icache_all();
21 
22 	if (IS_ENABLED(CONFIG_RISCV_SBI) && !riscv_use_ipi_for_rfence())
23 		sbi_remote_fence_i(NULL);
24 	else
25 		on_each_cpu(ipi_remote_fence_i, NULL, 1);
26 }
27 EXPORT_SYMBOL(flush_icache_all);
28 
29 /*
30  * Performs an icache flush for the given MM context.  RISC-V has no direct
31  * mechanism for instruction cache shoot downs, so instead we send an IPI that
32  * informs the remote harts they need to flush their local instruction caches.
33  * To avoid pathologically slow behavior in a common case (a bunch of
34  * single-hart processes on a many-hart machine, ie 'make -j') we avoid the
35  * IPIs for harts that are not currently executing a MM context and instead
36  * schedule a deferred local instruction cache flush to be performed before
37  * execution resumes on each hart.
38  */
39 void flush_icache_mm(struct mm_struct *mm, bool local)
40 {
41 	unsigned int cpu;
42 	cpumask_t others, *mask;
43 
44 	preempt_disable();
45 
46 	/* Mark every hart's icache as needing a flush for this MM. */
47 	mask = &mm->context.icache_stale_mask;
48 	cpumask_setall(mask);
49 	/* Flush this hart's I$ now, and mark it as flushed. */
50 	cpu = smp_processor_id();
51 	cpumask_clear_cpu(cpu, mask);
52 	local_flush_icache_all();
53 
54 	/*
55 	 * Flush the I$ of other harts concurrently executing, and mark them as
56 	 * flushed.
57 	 */
58 	cpumask_andnot(&others, mm_cpumask(mm), cpumask_of(cpu));
59 	local |= cpumask_empty(&others);
60 	if (mm == current->active_mm && local) {
61 		/*
62 		 * It's assumed that at least one strongly ordered operation is
63 		 * performed on this hart between setting a hart's cpumask bit
64 		 * and scheduling this MM context on that hart.  Sending an SBI
65 		 * remote message will do this, but in the case where no
66 		 * messages are sent we still need to order this hart's writes
67 		 * with flush_icache_deferred().
68 		 */
69 		smp_mb();
70 	} else if (IS_ENABLED(CONFIG_RISCV_SBI) &&
71 		   !riscv_use_ipi_for_rfence()) {
72 		sbi_remote_fence_i(&others);
73 	} else {
74 		on_each_cpu_mask(&others, ipi_remote_fence_i, NULL, 1);
75 	}
76 
77 	preempt_enable();
78 }
79 
80 #endif /* CONFIG_SMP */
81 
82 #ifdef CONFIG_MMU
83 void flush_icache_pte(pte_t pte)
84 {
85 	struct page *page = pte_page(pte);
86 
87 	/*
88 	 * HugeTLB pages are always fully mapped, so only setting head page's
89 	 * PG_dcache_clean flag is enough.
90 	 */
91 	if (PageHuge(page))
92 		page = compound_head(page);
93 
94 	if (!test_bit(PG_dcache_clean, &page->flags)) {
95 		flush_icache_all();
96 		set_bit(PG_dcache_clean, &page->flags);
97 	}
98 }
99 #endif /* CONFIG_MMU */
100 
101 unsigned int riscv_cbom_block_size;
102 EXPORT_SYMBOL_GPL(riscv_cbom_block_size);
103 
104 unsigned int riscv_cboz_block_size;
105 EXPORT_SYMBOL_GPL(riscv_cboz_block_size);
106 
107 static void cbo_get_block_size(struct device_node *node,
108 			       const char *name, u32 *block_size,
109 			       unsigned long *first_hartid)
110 {
111 	unsigned long hartid;
112 	u32 val;
113 
114 	if (riscv_of_processor_hartid(node, &hartid))
115 		return;
116 
117 	if (of_property_read_u32(node, name, &val))
118 		return;
119 
120 	if (!*block_size) {
121 		*block_size = val;
122 		*first_hartid = hartid;
123 	} else if (*block_size != val) {
124 		pr_warn("%s mismatched between harts %lu and %lu\n",
125 			name, *first_hartid, hartid);
126 	}
127 }
128 
129 void riscv_init_cbo_blocksizes(void)
130 {
131 	unsigned long cbom_hartid, cboz_hartid;
132 	u32 cbom_block_size = 0, cboz_block_size = 0;
133 	struct device_node *node;
134 
135 	for_each_of_cpu_node(node) {
136 		/* set block-size for cbom and/or cboz extension if available */
137 		cbo_get_block_size(node, "riscv,cbom-block-size",
138 				   &cbom_block_size, &cbom_hartid);
139 		cbo_get_block_size(node, "riscv,cboz-block-size",
140 				   &cboz_block_size, &cboz_hartid);
141 	}
142 
143 	if (cbom_block_size)
144 		riscv_cbom_block_size = cbom_block_size;
145 
146 	if (cboz_block_size)
147 		riscv_cboz_block_size = cboz_block_size;
148 }
149