1# SPDX-License-Identifier: GPL-2.0 2# 3# KVM configuration 4# 5 6source "virt/kvm/Kconfig" 7 8menuconfig VIRTUALIZATION 9 bool "Virtualization" 10 ---help--- 11 Say Y here to get to see options for using your Linux host to run 12 other operating systems inside virtual machines (guests). 13 This option alone does not add any kernel code. 14 15 If you say N, all options in this submenu will be skipped and 16 disabled. 17 18if VIRTUALIZATION 19 20config KVM 21 bool 22 select PREEMPT_NOTIFIERS 23 select HAVE_KVM_EVENTFD 24 select HAVE_KVM_VCPU_ASYNC_IOCTL 25 select SRCU 26 select KVM_VFIO 27 select IRQ_BYPASS_MANAGER 28 select HAVE_KVM_IRQ_BYPASS 29 30config KVM_BOOK3S_HANDLER 31 bool 32 33config KVM_BOOK3S_32_HANDLER 34 bool 35 select KVM_BOOK3S_HANDLER 36 select KVM_MMIO 37 38config KVM_BOOK3S_64_HANDLER 39 bool 40 select KVM_BOOK3S_HANDLER 41 select PPC_DAWR_FORCE_ENABLE 42 43config KVM_BOOK3S_PR_POSSIBLE 44 bool 45 select KVM_MMIO 46 select MMU_NOTIFIER 47 48config KVM_BOOK3S_HV_POSSIBLE 49 bool 50 51config KVM_BOOK3S_32 52 tristate "KVM support for PowerPC book3s_32 processors" 53 depends on PPC_BOOK3S_32 && !SMP && !PTE_64BIT 54 select KVM 55 select KVM_BOOK3S_32_HANDLER 56 select KVM_BOOK3S_PR_POSSIBLE 57 ---help--- 58 Support running unmodified book3s_32 guest kernels 59 in virtual machines on book3s_32 host processors. 60 61 This module provides access to the hardware capabilities through 62 a character device node named /dev/kvm. 63 64 If unsure, say N. 65 66config KVM_BOOK3S_64 67 tristate "KVM support for PowerPC book3s_64 processors" 68 depends on PPC_BOOK3S_64 69 select KVM_BOOK3S_64_HANDLER 70 select KVM 71 select KVM_BOOK3S_PR_POSSIBLE if !KVM_BOOK3S_HV_POSSIBLE 72 select SPAPR_TCE_IOMMU if IOMMU_SUPPORT && (PPC_PSERIES || PPC_POWERNV) 73 ---help--- 74 Support running unmodified book3s_64 and book3s_32 guest kernels 75 in virtual machines on book3s_64 host processors. 76 77 This module provides access to the hardware capabilities through 78 a character device node named /dev/kvm. 79 80 If unsure, say N. 81 82config KVM_BOOK3S_64_HV 83 tristate "KVM for POWER7 and later using hypervisor mode in host" 84 depends on KVM_BOOK3S_64 && PPC_POWERNV 85 select KVM_BOOK3S_HV_POSSIBLE 86 select MMU_NOTIFIER 87 select CMA 88 ---help--- 89 Support running unmodified book3s_64 guest kernels in 90 virtual machines on POWER7 and newer processors that have 91 hypervisor mode available to the host. 92 93 If you say Y here, KVM will use the hardware virtualization 94 facilities of POWER7 (and later) processors, meaning that 95 guest operating systems will run at full hardware speed 96 using supervisor and user modes. However, this also means 97 that KVM is not usable under PowerVM (pHyp), is only usable 98 on POWER7 or later processors, and cannot emulate a 99 different processor from the host processor. 100 101 If unsure, say N. 102 103config KVM_BOOK3S_64_PR 104 tristate "KVM support without using hypervisor mode in host" 105 depends on KVM_BOOK3S_64 106 select KVM_BOOK3S_PR_POSSIBLE 107 ---help--- 108 Support running guest kernels in virtual machines on processors 109 without using hypervisor mode in the host, by running the 110 guest in user mode (problem state) and emulating all 111 privileged instructions and registers. 112 113 This is not as fast as using hypervisor mode, but works on 114 machines where hypervisor mode is not available or not usable, 115 and can emulate processors that are different from the host 116 processor, including emulating 32-bit processors on a 64-bit 117 host. 118 119config KVM_BOOK3S_HV_EXIT_TIMING 120 bool "Detailed timing for hypervisor real-mode code" 121 depends on KVM_BOOK3S_HV_POSSIBLE && DEBUG_FS 122 ---help--- 123 Calculate time taken for each vcpu in the real-mode guest entry, 124 exit, and interrupt handling code, plus time spent in the guest 125 and in nap mode due to idle (cede) while other threads are still 126 in the guest. The total, minimum and maximum times in nanoseconds 127 together with the number of executions are reported in debugfs in 128 kvm/vm#/vcpu#/timings. The overhead is of the order of 30 - 40 129 ns per exit on POWER8. 130 131 If unsure, say N. 132 133config KVM_BOOKE_HV 134 bool 135 136config KVM_EXIT_TIMING 137 bool "Detailed exit timing" 138 depends on KVM_E500V2 || KVM_E500MC 139 ---help--- 140 Calculate elapsed time for every exit/enter cycle. A per-vcpu 141 report is available in debugfs kvm/vm#_vcpu#_timing. 142 The overhead is relatively small, however it is not recommended for 143 production environments. 144 145 If unsure, say N. 146 147config KVM_E500V2 148 bool "KVM support for PowerPC E500v2 processors" 149 depends on E500 && !PPC_E500MC 150 select KVM 151 select KVM_MMIO 152 select MMU_NOTIFIER 153 ---help--- 154 Support running unmodified E500 guest kernels in virtual machines on 155 E500v2 host processors. 156 157 This module provides access to the hardware capabilities through 158 a character device node named /dev/kvm. 159 160 If unsure, say N. 161 162config KVM_E500MC 163 bool "KVM support for PowerPC E500MC/E5500/E6500 processors" 164 depends on PPC_E500MC 165 select KVM 166 select KVM_MMIO 167 select KVM_BOOKE_HV 168 select MMU_NOTIFIER 169 ---help--- 170 Support running unmodified E500MC/E5500/E6500 guest kernels in 171 virtual machines on E500MC/E5500/E6500 host processors. 172 173 This module provides access to the hardware capabilities through 174 a character device node named /dev/kvm. 175 176 If unsure, say N. 177 178config KVM_MPIC 179 bool "KVM in-kernel MPIC emulation" 180 depends on KVM && E500 181 select HAVE_KVM_IRQCHIP 182 select HAVE_KVM_IRQFD 183 select HAVE_KVM_IRQ_ROUTING 184 select HAVE_KVM_MSI 185 help 186 Enable support for emulating MPIC devices inside the 187 host kernel, rather than relying on userspace to emulate. 188 Currently, support is limited to certain versions of 189 Freescale's MPIC implementation. 190 191config KVM_XICS 192 bool "KVM in-kernel XICS emulation" 193 depends on KVM_BOOK3S_64 && !KVM_MPIC 194 select HAVE_KVM_IRQCHIP 195 select HAVE_KVM_IRQFD 196 default y 197 ---help--- 198 Include support for the XICS (eXternal Interrupt Controller 199 Specification) interrupt controller architecture used on 200 IBM POWER (pSeries) servers. 201 202config KVM_XIVE 203 bool 204 default y 205 depends on KVM_XICS && PPC_XIVE_NATIVE && KVM_BOOK3S_HV_POSSIBLE 206 207endif # VIRTUALIZATION 208