1Kernel driver adt7410 2===================== 3 4Supported chips: 5 6 * Analog Devices ADT7410 7 8 Prefix: 'adt7410' 9 10 Addresses scanned: None 11 12 Datasheet: Publicly available at the Analog Devices website 13 14 http://www.analog.com/static/imported-files/data_sheets/ADT7410.pdf 15 * Analog Devices ADT7420 16 17 Prefix: 'adt7420' 18 19 Addresses scanned: None 20 21 Datasheet: Publicly available at the Analog Devices website 22 23 http://www.analog.com/static/imported-files/data_sheets/ADT7420.pdf 24 25 * Analog Devices ADT7310 26 27 Prefix: 'adt7310' 28 29 Addresses scanned: None 30 31 Datasheet: Publicly available at the Analog Devices website 32 33 http://www.analog.com/static/imported-files/data_sheets/ADT7310.pdf 34 35 * Analog Devices ADT7320 36 37 Prefix: 'adt7320' 38 39 Addresses scanned: None 40 41 Datasheet: Publicly available at the Analog Devices website 42 43 http://www.analog.com/static/imported-files/data_sheets/ADT7320.pdf 44 45Author: Hartmut Knaack <knaack.h@gmx.de> 46 47Description 48----------- 49 50The ADT7310/ADT7410 is a temperature sensor with rated temperature range of 51-55°C to +150°C. It has a high accuracy of +/-0.5°C and can be operated at a 52resolution of 13 bits (0.0625°C) or 16 bits (0.0078°C). The sensor provides an 53INT pin to indicate that a minimum or maximum temperature set point has been 54exceeded, as well as a critical temperature (CT) pin to indicate that the 55critical temperature set point has been exceeded. Both pins can be set up with a 56common hysteresis of 0°C - 15°C and a fault queue, ranging from 1 to 4 events. 57Both pins can individually set to be active-low or active-high, while the whole 58device can either run in comparator mode or interrupt mode. The ADT7410 supports 59continuous temperature sampling, as well as sampling one temperature value per 60second or even just get one sample on demand for power saving. Besides, it can 61completely power down its ADC, if power management is required. 62 63The ADT7320/ADT7420 is register compatible, the only differences being the 64package, a slightly narrower operating temperature range (-40°C to +150°C), and 65a better accuracy (0.25°C instead of 0.50°C.) 66 67The difference between the ADT7310/ADT7320 and ADT7410/ADT7420 is the control 68interface, the ADT7310 and ADT7320 use SPI while the ADT7410 and ADT7420 use 69I2C. 70 71Configuration Notes 72------------------- 73 74Since the device uses one hysteresis value, which is an offset to minimum, 75maximum and critical temperature, it can only be set for temp#_max_hyst. 76However, temp#_min_hyst and temp#_crit_hyst show their corresponding 77hysteresis. 78The device is set to 16 bit resolution and comparator mode. 79 80sysfs-Interface 81--------------- 82 83======================== ==================================================== 84temp#_input temperature input 85temp#_min temperature minimum setpoint 86temp#_max temperature maximum setpoint 87temp#_crit critical temperature setpoint 88temp#_min_hyst hysteresis for temperature minimum (read-only) 89temp#_max_hyst hysteresis for temperature maximum (read/write) 90temp#_crit_hyst hysteresis for critical temperature (read-only) 91temp#_min_alarm temperature minimum alarm flag 92temp#_max_alarm temperature maximum alarm flag 93temp#_crit_alarm critical temperature alarm flag 94======================== ==================================================== 95