1Actions Semi Owl Timer 2 3Required properties: 4- compatible : "actions,s500-timer" for S500 5 "actions,s700-timer" for S700 6 "actions,s900-timer" for S900 7- reg : Offset and length of the register set for the device. 8- interrupts : Should contain the interrupts. 9- interrupt-names : Valid names are: "2hz0", "2hz1", 10 "timer0", "timer1", "timer2", "timer3" 11 See ../resource-names.txt 12 13Example: 14 15 timer@b0168000 { 16 compatible = "actions,s500-timer"; 17 reg = <0xb0168000 0x100>; 18 interrupts = <GIC_SPI 10 IRQ_TYPE_LEVEL_HIGH>, 19 <GIC_SPI 11 IRQ_TYPE_LEVEL_HIGH>; 20 interrupt-names = "timer0", "timer1"; 21 }; 22