1Amlogic Meson Power Controller
2==============================
3
4The Amlogic Meson SoCs embeds an internal Power domain controller.
5
6VPU Power Domain
7----------------
8
9The Video Processing Unit power domain is controlled by this power controller,
10but the domain requires some external resources to meet the correct power
11sequences.
12The bindings must respect the power domain bindings as described in the file
13power_domain.txt
14
15Device Tree Bindings:
16---------------------
17
18Required properties:
19- compatible: should be "amlogic,meson-gx-pwrc-vpu" for the Meson GX SoCs
20- #power-domain-cells: should be 0
21- amlogic,hhi-sysctrl: phandle to the HHI sysctrl node
22- resets: phandles to the reset lines needed for this power demain sequence
23	as described in ../reset/reset.txt
24- clocks: from common clock binding: handle to VPU and VAPB clocks
25- clock-names: from common clock binding: must contain "vpu", "vapb"
26	corresponding to entry in the clocks property.
27
28Parent node should have the following properties :
29- compatible: "amlogic,meson-gx-ao-sysctrl", "syscon", "simple-mfd"
30- reg: base address and size of the AO system control register space.
31
32Example:
33-------
34
35ao_sysctrl: sys-ctrl@0 {
36	compatible = "amlogic,meson-gx-ao-sysctrl", "syscon", "simple-mfd";
37	reg =  <0x0 0x0 0x0 0x100>;
38
39	pwrc_vpu: power-controller-vpu {
40		compatible = "amlogic,meson-gx-pwrc-vpu";
41		#power-domain-cells = <0>;
42		amlogic,hhi-sysctrl = <&sysctrl>;
43		resets = <&reset RESET_VIU>,
44			 <&reset RESET_VENC>,
45			 <&reset RESET_VCBUS>,
46			 <&reset RESET_BT656>,
47			 <&reset RESET_DVIN_RESET>,
48			 <&reset RESET_RDMA>,
49			 <&reset RESET_VENCI>,
50			 <&reset RESET_VENCP>,
51			 <&reset RESET_VDAC>,
52			 <&reset RESET_VDI6>,
53			 <&reset RESET_VENCL>,
54			 <&reset RESET_VID_LOCK>;
55		clocks = <&clkc CLKID_VPU>,
56			 <&clkc CLKID_VAPB>;
57		clock-names = "vpu", "vapb";
58	};
59};
60
61
62