1Micrel PHY properties. 2 3These properties cover the base properties Micrel PHYs. 4 5Optional properties: 6 7 - micrel,led-mode : LED mode value to set for PHYs with configurable LEDs. 8 9 Configure the LED mode with single value. The list of PHYs and the 10 bits that are currently supported: 11 12 KSZ8001: register 0x1e, bits 15..14 13 KSZ8041: register 0x1e, bits 15..14 14 KSZ8021: register 0x1f, bits 5..4 15 KSZ8031: register 0x1f, bits 5..4 16 KSZ8051: register 0x1f, bits 5..4 17 KSZ8081: register 0x1f, bits 5..4 18 KSZ8091: register 0x1f, bits 5..4 19 20 See the respective PHY datasheet for the mode values. 21 22 - micrel,rmii-reference-clock-select-25-mhz: RMII Reference Clock Select 23 bit selects 25 MHz mode 24 25 Setting the RMII Reference Clock Select bit enables 25 MHz rather 26 than 50 MHz clock mode. 27 28 Note that this option in only needed for certain PHY revisions with a 29 non-standard, inverted function of this configuration bit. 30 Specifically, a clock reference ("rmii-ref" below) is always needed to 31 actually select a mode. 32 33 - clocks, clock-names: contains clocks according to the common clock bindings. 34 35 supported clocks: 36 - KSZ8021, KSZ8031, KSZ8081, KSZ8091: "rmii-ref": The RMII reference 37 input clock. Used to determine the XI input clock. 38 39 - micrel,fiber-mode: If present the PHY is configured to operate in fiber mode 40 41 Some PHYs, such as the KSZ8041FTL variant, support fiber mode, enabled 42 by the FXEN boot strapping pin. It can't be determined from the PHY 43 registers whether the PHY is in fiber mode, so this boolean device tree 44 property can be used to describe it. 45 46 In fiber mode, auto-negotiation is disabled and the PHY can only work in 47 100base-fx (full and half duplex) modes. 48