1-------------------------------
2BCM590xx Power Management Units
3-------------------------------
4
5Required properties:
6- compatible: "brcm,bcm59056"
7- reg: I2C slave address
8- interrupts: interrupt for the PMU. Generic interrupt client node bindings
9  are described in interrupt-controller/interrupts.txt
10
11------------------
12Voltage Regulators
13------------------
14
15Optional child nodes:
16- regulators: container node for regulators following the generic
17  regulator binding in regulator/regulator.txt
18
19  The valid regulator node names for BCM59056 are:
20  	rfldo, camldo1, camldo2, simldo1, simldo2, sdldo, sdxldo,
21	mmcldo1, mmcldo2, audldo, micldo, usbldo, vibldo,
22	csr, iosr1, iosr2, msr, sdsr1, sdsr2, vsr,
23	gpldo1, gpldo2, gpldo3, gpldo4, gpldo5, gpldo6,
24	vbus
25
26Example:
27	pmu: bcm59056@8 {
28		compatible = "brcm,bcm59056";
29		reg = <0x08>;
30		interrupts = <GIC_SPI 215 IRQ_TYPE_LEVEL_HIGH>;
31		regulators {
32			rfldo_reg: rfldo {
33				regulator-min-microvolt = <1200000>;
34				regulator-max-microvolt = <3300000>;
35			};
36
37			...
38		};
39	};
40