1Device Tree Clock bindings for cpu clock of Marvell EBU platforms 2 3Required properties: 4- compatible : shall be one of the following: 5 "marvell,armada-xp-cpu-clock" - cpu clocks for Armada XP 6- reg : Address and length of the clock complex register set 7- #clock-cells : should be set to 1. 8- clocks : shall be the input parent clock phandle for the clock. 9 10cpuclk: clock-complex@d0018700 { 11 #clock-cells = <1>; 12 compatible = "marvell,armada-xp-cpu-clock"; 13 reg = <0xd0018700 0xA0>; 14 clocks = <&coreclk 1>; 15} 16 17cpu@0 { 18 compatible = "marvell,sheeva-v7"; 19 reg = <0>; 20 clocks = <&cpuclk 0>; 21}; 22