1What:		/sys/bus/iio/devices/iio:deviceX/sensor_max_range
2Date:		January 2017
3KernelVersion:	4.11
4Contact:	linux-iio@vger.kernel.org
5Description:
6                Show or set the maximum range between the sensor and the
7		first object echoed in meters. Default value is 6.020.
8		This setting limits the time the driver is waiting for a
9		echo.
10
11		Showing the range of available values is represented as the
12		minimum value, the step and the maximum value, all enclosed
13		in square brackets.
14
15		Example::
16
17			[0.043 0.043 11.008]
18