xref: /openbmc/linux/Documentation/ABI/testing/sysfs-bus-iio-adc-max9611 (revision a976c2951d8f376112361830aa7762beff83a205)
1*3fed601cSJacopo MondiWhat:		/sys/bus/iio/devices/iio:deviceX/in_power_shunt_resistor
2*3fed601cSJacopo MondiDate:		March 2017
3*3fed601cSJacopo MondiKernelVersion:	4.12
4*3fed601cSJacopo MondiContact:	linux-iio@vger.kernel.org
5*3fed601cSJacopo MondiDescription: 	The value of the shunt resistor used to compute power drain on
6*3fed601cSJacopo Mondi                common input voltage pin (RS+). In Ohms.
7*3fed601cSJacopo Mondi
8*3fed601cSJacopo MondiWhat:		/sys/bus/iio/devices/iio:deviceX/in_current_shunt_resistor
9*3fed601cSJacopo MondiDate:		March 2017
10*3fed601cSJacopo MondiKernelVersion:	4.12
11*3fed601cSJacopo MondiContact:	linux-iio@vger.kernel.org
12*3fed601cSJacopo MondiDescription: 	The value of the shunt resistor used to compute current flowing
13*3fed601cSJacopo Mondi                between RS+ and RS- voltage sense inputs. In Ohms.
14*3fed601cSJacopo Mondi
15*3fed601cSJacopo MondiThese attributes describe a single physical component, exposed as two distinct
16*3fed601cSJacopo Mondiattributes as it is used to calculate two different values: power load and
17*3fed601cSJacopo Mondicurrent flowing between RS+ and RS- inputs.
18