1bdc76dacSPotin Lai{
2bdc76dacSPotin Lai    "Exposes": [
3bdc76dacSPotin Lai        {
4bdc76dacSPotin Lai            "Address": "$address",
5bdc76dacSPotin Lai            "Bus": "$bus",
6bdc76dacSPotin Lai            "Name": "Catalina HDD Board FRU",
7bdc76dacSPotin Lai            "Type": "EEPROM"
8bdc76dacSPotin Lai        },
9bdc76dacSPotin Lai        {
10bdc76dacSPotin Lai            "Address": "0x40",
11bdc76dacSPotin Lai            "Bus": 55,
12bdc76dacSPotin Lai            "Labels": [
13bdc76dacSPotin Lai                "in1",
14bdc76dacSPotin Lai                "curr1",
15bdc76dacSPotin Lai                "power1"
16bdc76dacSPotin Lai            ],
17bdc76dacSPotin Lai            "Name": "HDDBOARD_SSD0_INA230",
18*ae8845c7SPotin Lai            "PowerState": "On",
1918a61cb1SPotin Lai            "Thresholds": [
2018a61cb1SPotin Lai                {
2118a61cb1SPotin Lai                    "Direction": "greater than",
2218a61cb1SPotin Lai                    "Label": "in1",
2318a61cb1SPotin Lai                    "Name": "upper critical",
2418a61cb1SPotin Lai                    "Severity": 1,
2518a61cb1SPotin Lai                    "Value": 13.6
2618a61cb1SPotin Lai                },
2718a61cb1SPotin Lai                {
2818a61cb1SPotin Lai                    "Direction": "less than",
2918a61cb1SPotin Lai                    "Label": "in1",
3018a61cb1SPotin Lai                    "Name": "lower critical",
3118a61cb1SPotin Lai                    "Severity": 1,
3218a61cb1SPotin Lai                    "Value": 10.5
3318a61cb1SPotin Lai                }
3418a61cb1SPotin Lai            ],
35bdc76dacSPotin Lai            "Type": "INA230",
36bdc76dacSPotin Lai            "curr1_Name": "HDDBOARD_SSD0_P12V_CURR_A",
37bdc76dacSPotin Lai            "in1_Name": "HDDBOARD_SSD0_P12V_VOLT_V",
38bdc76dacSPotin Lai            "power1_Name": "HDDBOARD_SSD0_P12V_PWR_W"
39bdc76dacSPotin Lai        },
40bdc76dacSPotin Lai        {
41bdc76dacSPotin Lai            "Address": "0x41",
42bdc76dacSPotin Lai            "Bus": 55,
43bdc76dacSPotin Lai            "Labels": [
44bdc76dacSPotin Lai                "in1",
45bdc76dacSPotin Lai                "curr1",
46bdc76dacSPotin Lai                "power1"
47bdc76dacSPotin Lai            ],
48bdc76dacSPotin Lai            "Name": "HDDBOARD_SSD1_INA230",
49*ae8845c7SPotin Lai            "PowerState": "On",
5018a61cb1SPotin Lai            "Thresholds": [
5118a61cb1SPotin Lai                {
5218a61cb1SPotin Lai                    "Direction": "greater than",
5318a61cb1SPotin Lai                    "Label": "in1",
5418a61cb1SPotin Lai                    "Name": "upper critical",
5518a61cb1SPotin Lai                    "Severity": 1,
5618a61cb1SPotin Lai                    "Value": 13.6
5718a61cb1SPotin Lai                },
5818a61cb1SPotin Lai                {
5918a61cb1SPotin Lai                    "Direction": "less than",
6018a61cb1SPotin Lai                    "Label": "in1",
6118a61cb1SPotin Lai                    "Name": "lower critical",
6218a61cb1SPotin Lai                    "Severity": 1,
6318a61cb1SPotin Lai                    "Value": 10.5
6418a61cb1SPotin Lai                }
6518a61cb1SPotin Lai            ],
66bdc76dacSPotin Lai            "Type": "INA230",
67bdc76dacSPotin Lai            "curr1_Name": "HDDBOARD_SSD1_P12V_CURR_A",
68bdc76dacSPotin Lai            "in1_Name": "HDDBOARD_SSD1_P12V_VOLT_V",
69bdc76dacSPotin Lai            "power1_Name": "HDDBOARD_SSD1_P12V_PWR_W"
70bdc76dacSPotin Lai        },
71bdc76dacSPotin Lai        {
72bdc76dacSPotin Lai            "Address": "0x44",
73bdc76dacSPotin Lai            "Bus": 55,
74bdc76dacSPotin Lai            "Labels": [
75bdc76dacSPotin Lai                "in1",
76bdc76dacSPotin Lai                "curr1",
77bdc76dacSPotin Lai                "power1"
78bdc76dacSPotin Lai            ],
79bdc76dacSPotin Lai            "Name": "HDDBOARD_SSD2_INA230",
80*ae8845c7SPotin Lai            "PowerState": "On",
8118a61cb1SPotin Lai            "Thresholds": [
8218a61cb1SPotin Lai                {
8318a61cb1SPotin Lai                    "Direction": "greater than",
8418a61cb1SPotin Lai                    "Label": "in1",
8518a61cb1SPotin Lai                    "Name": "upper critical",
8618a61cb1SPotin Lai                    "Severity": 1,
8718a61cb1SPotin Lai                    "Value": 13.6
8818a61cb1SPotin Lai                },
8918a61cb1SPotin Lai                {
9018a61cb1SPotin Lai                    "Direction": "less than",
9118a61cb1SPotin Lai                    "Label": "in1",
9218a61cb1SPotin Lai                    "Name": "lower critical",
9318a61cb1SPotin Lai                    "Severity": 1,
9418a61cb1SPotin Lai                    "Value": 10.5
9518a61cb1SPotin Lai                }
9618a61cb1SPotin Lai            ],
97bdc76dacSPotin Lai            "Type": "INA230",
98bdc76dacSPotin Lai            "curr1_Name": "HDDBOARD_SSD2_P12V_CURR_A",
99bdc76dacSPotin Lai            "in1_Name": "HDDBOARD_SSD2_P12V_VOLT_V",
100bdc76dacSPotin Lai            "power1_Name": "HDDBOARD_SSD2_P12V_PWR_W"
101bdc76dacSPotin Lai        },
102bdc76dacSPotin Lai        {
103bdc76dacSPotin Lai            "Address": "0x45",
104bdc76dacSPotin Lai            "Bus": 55,
105bdc76dacSPotin Lai            "Labels": [
106bdc76dacSPotin Lai                "in1",
107bdc76dacSPotin Lai                "curr1",
108bdc76dacSPotin Lai                "power1"
109bdc76dacSPotin Lai            ],
110bdc76dacSPotin Lai            "Name": "HDDBOARD_SSD3_INA230",
111*ae8845c7SPotin Lai            "PowerState": "On",
11218a61cb1SPotin Lai            "Thresholds": [
11318a61cb1SPotin Lai                {
11418a61cb1SPotin Lai                    "Direction": "greater than",
11518a61cb1SPotin Lai                    "Label": "in1",
11618a61cb1SPotin Lai                    "Name": "upper critical",
11718a61cb1SPotin Lai                    "Severity": 1,
11818a61cb1SPotin Lai                    "Value": 13.6
11918a61cb1SPotin Lai                },
12018a61cb1SPotin Lai                {
12118a61cb1SPotin Lai                    "Direction": "less than",
12218a61cb1SPotin Lai                    "Label": "in1",
12318a61cb1SPotin Lai                    "Name": "lower critical",
12418a61cb1SPotin Lai                    "Severity": 1,
12518a61cb1SPotin Lai                    "Value": 10.5
12618a61cb1SPotin Lai                }
12718a61cb1SPotin Lai            ],
128bdc76dacSPotin Lai            "Type": "INA230",
129bdc76dacSPotin Lai            "curr1_Name": "HDDBOARD_SSD3_P12V_CURR_A",
130bdc76dacSPotin Lai            "in1_Name": "HDDBOARD_SSD3_P12V_VOLT_V",
131bdc76dacSPotin Lai            "power1_Name": "HDDBOARD_SSD3_P12V_PWR_W"
132bdc76dacSPotin Lai        }
133bdc76dacSPotin Lai    ],
134bdc76dacSPotin Lai    /* Catalina Hard Disk Drive Carrier Board */
135bdc76dacSPotin Lai    "Name": "Catalina HDD Carrier",
136bdc76dacSPotin Lai    "Probe": "xyz.openbmc_project.FruDevice({'BOARD_PRODUCT_NAME': 'Catalina HDD ', 'BOARD_MANUFACTURER': 'Quanta'})",
137bdc76dacSPotin Lai    "Type": "Board",
138bdc76dacSPotin Lai    "xyz.openbmc_project.Inventory.Decorator.Asset": {
139bdc76dacSPotin Lai        "BuildDate": "$BOARD_MANUFACTURE_DATE",
140bdc76dacSPotin Lai        "Manufacturer": "$BOARD_MANUFACTURER",
141bdc76dacSPotin Lai        "Model": "$BOARD_PRODUCT_NAME",
142bdc76dacSPotin Lai        "PartNumber": "$BOARD_PART_NUMBER",
143bdc76dacSPotin Lai        "SerialNumber": "$BOARD_SERIAL_NUMBER",
144bdc76dacSPotin Lai        "SparePartNumber": "$BOARD_INFO_AM1"
145bdc76dacSPotin Lai    },
146bdc76dacSPotin Lai    "xyz.openbmc_project.Inventory.Decorator.AssetTag": {
147bdc76dacSPotin Lai        "AssetTag": "$PRODUCT_ASSET_TAG"
148bdc76dacSPotin Lai    },
149bdc76dacSPotin Lai    "xyz.openbmc_project.Inventory.Decorator.Revision": {
150bdc76dacSPotin Lai        "Version": "$PRODUCT_VERSION"
151bdc76dacSPotin Lai    }
152bdc76dacSPotin Lai}
153