1# BMC Reset with Host Booted 2 3Author: Andrew Geissler (geissonator) 4 5Primary assignee: Andrew Geissler (geissonator) 6 7Other contributors: 8 9Created: June 23rd, 2020 10 11## Problem Description 12BMCs can reboot for a lot of different reasons. User request, firmware update, 13and a variety of different error scenarios. When the BMC is rebooted while the 14host is up and running, there needs to be a process by which the two synchronize 15with each other and the BMC gets itself into a state that matches with the host. 16 17## Background and References 18A good portion of this is explained in the phosphor-state-manager [README][1]. 19 20This design doc is written to formalize the design and add some more 21details on dealing with both IPMI and PLDM communication to the host as well as 22desired behavior when unable to talk with the host. 23 24The high level flow is that OpenBMC software first checks for pgood, and if set, 25it then checks the host to see if it is up and alive. If the power is on and the 26host is running, then files are created in the filesystem to indicate this: 27- /run/openbmc/chassis@0-on 28- /run/openbmc/host@0-on 29 30It should be noted that although full support is not in place for multi-chassis 31and multi-host systems, the framework is there to build on. 32`op-reset-chassis-running@.service` is a templated service, checking pgood in 33its instances power domain. It creates a file in the filesystem, 34/run/openbmc/chassis@%i-on, to indicate power is on for that instance. Similar 35implementation is done for the host via `phosphor-reset-host-check@.service` and 36the file /run/openbmc/host@%i-on. 37 38If chassis power is on and the host is up, then 39`obmc-chassis-poweron@.target` and `obmc-host-start@.target` are started. 40 41The /run/ files are used by OpenBMC services to determine if they need to run 42or not when the chassis and host targets are started. For example, if the 43chassis is already powered on and the host is running, there is no need to 44actually turn power on, or start the host. The behavior wanted is that these 45services "start" but do nothing. That is commonly done within a systemd service 46file via the following: 47- `ConditionPathExists=!/run/openbmc/chassis@%i-on` 48- `ConditionPathExists=!/run/openbmc/host@%i-on` 49 50This allows the targets to start and for the BMC to get in synch with the 51state of the chassis and host without any special software checks. 52 53Different systems have different requirements on what the behavior should be 54when the chassis power is on, but the host is unreachable. This design needs to 55allow this customization. For example, some systems would prefer to just leave 56the system in whatever state it is in and let the user correct things. Some 57systems want to recover automatically (i.e. reboot the host) for the user. 58Some systems have a hybrid approach where depending on where the host was in 59its boot, the BMC may leave it or recover. 60 61## Requirements 62- Support both IPMI and PLDM as mechanisms to determine if the host is running. 63 - Allow either or both to be enabled 64- Support custom behavior when chassis power is on but the BMC is unable to 65 communicate with the host 66- Both IPMI and PLDM stacks will give the host a set amount of time to 67 respond. Lack of response within this time limit will result in the BMC 68 potentially taking recovery actions. 69 - This time limit must be configurable at build time 70- IPMI and PLDM will implement a phosphor-dbus-interface interface, 71 `xyz.openbmc_project.Condition.HostFirmware`, which will have a 72 `CurrentFirmwareCondition` property which other applications can read to 73 determine if the host is running. 74 75### IPMI Detailed Requirements 76- IPMI will continue to utilize the SMS_ATN command to indicate to the host that 77 a "Get Message Flags Command" is requested. Upon the host issuing that 78 command, it will be considered up and running 79 80### PLDM Detailed Requirements 81- PLDM will utilize a GetTID command to the host to determine if it is running 82- Where applicable, PLDM will provide a mechanism to distinguish between 83 different host firmware stacks 84 - For example, on IBM systems there is a difference between the 85 hostboot (host initialization) firmware and Hypervisor firmware stacks. 86 Both are host firmware and talking PLDM but the BMC recovery paths will 87 differ based on which is running. The `CurrentFirmwareCondition` property 88 should not return "Running" unless the Hypervisor firmware is running. 89 90## Proposed Design 91High Level Flow: 92- Check pgood 93- Call mapper for all implementations of 94 `xyz.openbmc_project.Condition.HostFirmware` PDI interface 95- Read `CurrentFirmwareCondition` property of all interface. If any call returns 96 that a host is running then create file and start host target. 97- Otherwise, check host via any custom mechanisms 98- Execute automated recovery of host if desired 99 100IPMI and PLDM software will be started as applicable. A combination of systemd 101services and applications within phosphor-state-manager will coordinate the 102checking of pgood, and if set, request the IPMI and PLDM applications to 103discover if the host is running. Based on the response from these queries 104the software in phosphor-state-manager will take the appropriate action of 105creating the /run files and starting the chassis and host targets or entering 106into recovery of the host. 107 108The systemd targets responsible for this and any common services will be hosted 109within phosphor-state-manager. Any system or company specific services can 110be installed in the common targets: 111- obmc-chassis-powerreset@.target.require 112- obmc-host-reset@.target.requires 113 114### Automated Recovery when host does not respond 115 116A separate service and application will be created within phosphor-state-manager 117to execute the following logic in situations where chassis power is on 118but the host has failed to respond to any of the different mechanisms to 119communicate with it: 120- If chassis power on (/run/openbmc/chassis@%i-on) 121- And host is off (!ConditionPathExists=!/run/openbmc/host@%i-on) 122- And restored BootProgress is not None 123- Then (assume host was booting before BMC reboot) 124 - Log error indicating situation 125 - Move host to Quiesce and allow automated recovery to kick in 126 127### Note on custom mechanism for IBM systems 128IBM systems will utilize a processor CFAM register. The specific register is 129**Mailbox scratch register 12**. 130 131If the chassis power is on but the BMC is unable to communicate with the 132host via IPMI or PLDM, then the BMC will read this processor CFAM register. 133 134The Host code will write `0xA5000001` to this register to indicate when it has 135reached a state in which it can boot an operating system without needing the 136BMC. If the BMC sees this value written in the CFAM register, then it will leave 137the host as-is, even if it is unable to communicate with the host over IPMI or 138PLDM. It will log an error indicating it was unable to communicate with the host 139but it will also show the host state as `Running`. 140 141If the register is not `0xA5000001`, then the BMC will follow whatever recovery 142mechanisms are defined for when the host has a failure (most likely a reboot 143of the host). 144 145It is the responsibility of the host firmware to set this register as 146applicable during the boot of the system. Host firmware will clear this register 147in shutdown scenarios. To handle different host crash scenarios, the register 148will also be cleared by the BMC firmware on power off's, system checkstops, and 149during Memory Preserving reboots. 150 151 152## Alternatives Considered 153One thought was to avoid IPMI/PLDM all together and only use a "lowest common 154denominator" hardware register of some sort. The problem with that is you start 155creating your own protocol, and before you know it you have something like IPMI 156or PLDM anyway, except you created something custom. So 99% of the time the 157IPMI or PLDM path will be fine, and as a backup option, system owners can 158put their own custom host-detection applications in. 159 160## Impacts 161None 162 163## Testing 164The normal path of IPMI and PLDM will be simple to test. Boot your system and 165reboot the BMC. Verify the BMC chassis and host states are correct and verify 166the host continued to run without issue throughout the BMC reset. 167 168The more complicated tests will be error paths: 169- Reboot the BMC while the host is booting, but before it's in a state where 170 it can continue to run without the BMC. Verify the BMC detects this error 171 scenario once it comes back from its reboot and takes the proper recovery 172 actions for the host. 173- Reboot the BMC when the host is up and running but disable the IPMI/PLDM stack 174 on the host so it does not respond to the BMC when it comes back from its 175 reboot. Ensure the BMC follows the defined recovery for the system in this 176 situation. 177 178[1]: https://github.com/openbmc/phosphor-state-manager#bmc-reset-with-host-andor-chassis-on 179