1{ 2 "$id": "http://redfish.dmtf.org/schemas/v1/CoolantConnector.v1_0_2.json", 3 "$ref": "#/definitions/CoolantConnector", 4 "$schema": "http://redfish.dmtf.org/schemas/v1/redfish-schema-v1.json", 5 "copyright": "Copyright 2014-2024 DMTF. For the full DMTF copyright policy, see http://www.dmtf.org/about/policies/copyright", 6 "definitions": { 7 "Actions": { 8 "additionalProperties": false, 9 "description": "The available actions for this resource.", 10 "longDescription": "This type shall contain the available actions for this resource.", 11 "patternProperties": { 12 "^([a-zA-Z_][a-zA-Z0-9_]*)?@(odata|Redfish|Message)\\.[a-zA-Z_][a-zA-Z0-9_]*$": { 13 "description": "This property shall specify a valid odata or Redfish property.", 14 "type": [ 15 "array", 16 "boolean", 17 "integer", 18 "number", 19 "null", 20 "object", 21 "string" 22 ] 23 } 24 }, 25 "properties": { 26 "Oem": { 27 "$ref": "#/definitions/OemActions", 28 "description": "The available OEM-specific actions for this resource.", 29 "longDescription": "This property shall contain the available OEM-specific actions for this resource." 30 } 31 }, 32 "type": "object" 33 }, 34 "CoolantConnector": { 35 "additionalProperties": false, 36 "description": "The `CoolantConnector` schema describes a liquid coolant connector, including any associated instrumentation.", 37 "longDescription": "This resource shall represent a coolant connector for a Redfish implementation.", 38 "patternProperties": { 39 "^([a-zA-Z_][a-zA-Z0-9_]*)?@(odata|Redfish|Message)\\.[a-zA-Z_][a-zA-Z0-9_]*$": { 40 "description": "This property shall specify a valid odata or Redfish property.", 41 "type": [ 42 "array", 43 "boolean", 44 "integer", 45 "number", 46 "null", 47 "object", 48 "string" 49 ] 50 } 51 }, 52 "properties": { 53 "@odata.context": { 54 "$ref": "http://redfish.dmtf.org/schemas/v1/odata-v4.json#/definitions/context" 55 }, 56 "@odata.etag": { 57 "$ref": "http://redfish.dmtf.org/schemas/v1/odata-v4.json#/definitions/etag" 58 }, 59 "@odata.id": { 60 "$ref": "http://redfish.dmtf.org/schemas/v1/odata-v4.json#/definitions/id" 61 }, 62 "@odata.type": { 63 "$ref": "http://redfish.dmtf.org/schemas/v1/odata-v4.json#/definitions/type" 64 }, 65 "Actions": { 66 "$ref": "#/definitions/Actions", 67 "description": "The available actions for this resource.", 68 "longDescription": "This property shall contain the available actions for this resource." 69 }, 70 "Coolant": { 71 "$ref": "http://redfish.dmtf.org/schemas/v1/CoolingLoop.json#/definitions/Coolant", 72 "description": "Details about the coolant used in this unit.", 73 "longDescription": "This property shall contain details regarding the coolant contained or used by this unit." 74 }, 75 "CoolantConnectorType": { 76 "anyOf": [ 77 { 78 "$ref": "#/definitions/CoolantConnectorType" 79 }, 80 { 81 "type": "null" 82 } 83 ], 84 "description": "The type of coolant connector.", 85 "longDescription": "This property shall contain the type of coolant connector.", 86 "readonly": true 87 }, 88 "CoolingLoopName": { 89 "description": "The name of the cooling loop attached to this interface.", 90 "longDescription": "This property shall contain the name of the cooling loop attached to this interface. If the `CoolingLoop` link property is present, this property shall contain the value of the `Id` property in the resource referenced by that link.", 91 "readonly": false, 92 "type": [ 93 "string", 94 "null" 95 ] 96 }, 97 "CoolingManagerURI": { 98 "description": "The link to the application that manages the cooling loop.", 99 "format": "uri-reference", 100 "longDescription": "This property shall contain a URI to the application or device that provides administration or management of the cooling loop associated with this interface.", 101 "readonly": false, 102 "type": [ 103 "string", 104 "null" 105 ] 106 }, 107 "DeltaPressurekPa": { 108 "anyOf": [ 109 { 110 "$ref": "http://redfish.dmtf.org/schemas/v1/Sensor.json#/definitions/SensorExcerpt" 111 }, 112 { 113 "type": "null" 114 } 115 ], 116 "description": "The differential pressure (kPa).", 117 "excerptCopy": "SensorExcerpt", 118 "longDescription": "This property shall contain the pressure, in kilopascal units, for the difference in pressure between the supply and outflow or return connection to the cooling loop. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `PressurekPa`.", 119 "readonly": true 120 }, 121 "DeltaTemperatureCelsius": { 122 "anyOf": [ 123 { 124 "$ref": "http://redfish.dmtf.org/schemas/v1/Sensor.json#/definitions/SensorExcerpt" 125 }, 126 { 127 "type": "null" 128 } 129 ], 130 "description": "The differential temperature (C).", 131 "excerptCopy": "SensorExcerpt", 132 "longDescription": "This property shall contain the change in temperature, in degree Celsius units, between the supply connection and the outflow or return connection to the cooling loop. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Temperature`.", 133 "readonly": true 134 }, 135 "Description": { 136 "anyOf": [ 137 { 138 "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Description" 139 }, 140 { 141 "type": "null" 142 } 143 ], 144 "readonly": true 145 }, 146 "FlowLitersPerMinute": { 147 "anyOf": [ 148 { 149 "$ref": "http://redfish.dmtf.org/schemas/v1/Sensor.json#/definitions/SensorExcerpt" 150 }, 151 { 152 "type": "null" 153 } 154 ], 155 "description": "The liquid flow (L/min).", 156 "excerptCopy": "SensorExcerpt", 157 "longDescription": "This property shall contain the liquid flow rate, in liters per minute units, for this coolant connector. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `LiquidFlowLPM`.", 158 "readonly": true 159 }, 160 "HeatRemovedkW": { 161 "anyOf": [ 162 { 163 "$ref": "http://redfish.dmtf.org/schemas/v1/Sensor.json#/definitions/SensorExcerpt" 164 }, 165 { 166 "type": "null" 167 } 168 ], 169 "description": "The heat removed (kW) through this connector.", 170 "excerptCopy": "SensorExcerpt", 171 "longDescription": "This property shall contain the amount of heat removed, in kilowatt units, by the coolant flow through this connector. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Heat`.", 172 "readonly": true 173 }, 174 "Id": { 175 "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Id", 176 "readonly": true 177 }, 178 "Links": { 179 "$ref": "#/definitions/Links", 180 "description": "The links to other resources that are related to this resource.", 181 "longDescription": "This property shall contain links to resources that are related to but are not contained by, or subordinate to, this resource." 182 }, 183 "LocationIndicatorActive": { 184 "description": "An indicator allowing an operator to physically locate this resource.", 185 "longDescription": "This property shall contain the state of the indicator used to physically identify or locate this resource.", 186 "readonly": false, 187 "type": [ 188 "boolean", 189 "null" 190 ] 191 }, 192 "Name": { 193 "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Name", 194 "readonly": true 195 }, 196 "Oem": { 197 "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Oem", 198 "description": "The OEM extension property.", 199 "longDescription": "This property shall contain the OEM extensions. All values for properties that this object contains shall conform to the Redfish Specification-described requirements." 200 }, 201 "RatedFlowLitersPerMinute": { 202 "description": "The rated liquid flow (L/min) for this loop interface.", 203 "longDescription": "This property shall contain the rated liquid flow, in liters per minute units, for this loop interface.", 204 "minimum": 0, 205 "readonly": true, 206 "type": [ 207 "number", 208 "null" 209 ], 210 "units": "L/min" 211 }, 212 "RatedFlowPressurekPa": { 213 "description": "The pressure (kPa) at which the rated liquid flow is valid.", 214 "longDescription": "This property shall contain the pressure, in kilopascal units, that the rated liquid flow is valid for this connector.", 215 "minimum": 0, 216 "readonly": true, 217 "type": [ 218 "number", 219 "null" 220 ], 221 "units": "kPa" 222 }, 223 "RatedPressurekPa": { 224 "description": "The rated pressure (kPa) for this connector.", 225 "longDescription": "This property shall contain the rated maximum pressure, in kilopascal units, for this connector.", 226 "minimum": 0, 227 "readonly": true, 228 "type": [ 229 "number", 230 "null" 231 ], 232 "units": "kPa" 233 }, 234 "ReturnPressurekPa": { 235 "anyOf": [ 236 { 237 "$ref": "http://redfish.dmtf.org/schemas/v1/Sensor.json#/definitions/SensorExcerpt" 238 }, 239 { 240 "type": "null" 241 } 242 ], 243 "description": "The return pressure (kPa).", 244 "excerptCopy": "SensorExcerpt", 245 "longDescription": "This property shall contain the pressure, in kilopascal units, for the outflow or return connection to the cooling loop. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `PressurekPa`.", 246 "readonly": true 247 }, 248 "ReturnTemperatureCelsius": { 249 "anyOf": [ 250 { 251 "$ref": "http://redfish.dmtf.org/schemas/v1/Sensor.json#/definitions/SensorExcerpt" 252 }, 253 { 254 "type": "null" 255 } 256 ], 257 "description": "The return temperature (C).", 258 "excerptCopy": "SensorExcerpt", 259 "longDescription": "This property shall contain the temperature, in degree Celsius units, for the outflow or return connection to the cooling loop. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Temperature`.", 260 "readonly": true 261 }, 262 "Status": { 263 "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Status", 264 "description": "The status and health of the resource and its subordinate or dependent resources.", 265 "longDescription": "This property shall contain any status or health properties of the resource." 266 }, 267 "SupplyPressurekPa": { 268 "anyOf": [ 269 { 270 "$ref": "http://redfish.dmtf.org/schemas/v1/Sensor.json#/definitions/SensorExcerpt" 271 }, 272 { 273 "type": "null" 274 } 275 ], 276 "description": "The supply pressure (kPa).", 277 "excerptCopy": "SensorExcerpt", 278 "longDescription": "This property shall contain the pressure, in kilopascal units, for the intake or supply connection to the cooling loop. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `PressurekPa`.", 279 "readonly": true 280 }, 281 "SupplyTemperatureCelsius": { 282 "anyOf": [ 283 { 284 "$ref": "http://redfish.dmtf.org/schemas/v1/Sensor.json#/definitions/SensorExcerpt" 285 }, 286 { 287 "type": "null" 288 } 289 ], 290 "description": "The supply temperature (C).", 291 "excerptCopy": "SensorExcerpt", 292 "longDescription": "This property shall contain the temperature, in degree Celsius units, for the intake or supply connection to the cooling loop. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Temperature`.", 293 "readonly": true 294 } 295 }, 296 "required": [ 297 "@odata.id", 298 "@odata.type", 299 "Id", 300 "Name" 301 ], 302 "type": "object" 303 }, 304 "CoolantConnectorType": { 305 "enum": [ 306 "Pair", 307 "Supply", 308 "Return", 309 "Inline", 310 "Closed" 311 ], 312 "enumDescriptions": { 313 "Closed": "A closed or self-contained loop.", 314 "Inline": "An inline connection or measurement point.", 315 "Pair": "A connection pair.", 316 "Return": "A return or outflow connection.", 317 "Supply": "A supply or intake connection." 318 }, 319 "type": "string" 320 }, 321 "Links": { 322 "additionalProperties": false, 323 "description": "The links to other resources that are related to this resource.", 324 "longDescription": "This Redfish Specification-described type shall contain links to resources that are related to but are not contained by, or subordinate to, this resource.", 325 "patternProperties": { 326 "^([a-zA-Z_][a-zA-Z0-9_]*)?@(odata|Redfish|Message)\\.[a-zA-Z_][a-zA-Z0-9_]*$": { 327 "description": "This property shall specify a valid odata or Redfish property.", 328 "type": [ 329 "array", 330 "boolean", 331 "integer", 332 "number", 333 "null", 334 "object", 335 "string" 336 ] 337 } 338 }, 339 "properties": { 340 "ConnectedChassis": { 341 "description": "Any array of links to chassis at the other end of the connection.", 342 "items": { 343 "$ref": "http://redfish.dmtf.org/schemas/v1/Chassis.json#/definitions/Chassis" 344 }, 345 "longDescription": "This property shall contain an array of links to resources of type `Chassis` that represent the chassis at the other end of the connection.", 346 "readonly": false, 347 "type": "array" 348 }, 349 "ConnectedChassis@odata.count": { 350 "$ref": "http://redfish.dmtf.org/schemas/v1/odata-v4.json#/definitions/count" 351 }, 352 "ConnectedCoolingLoop": { 353 "anyOf": [ 354 { 355 "$ref": "http://redfish.dmtf.org/schemas/v1/CoolingLoop.json#/definitions/CoolingLoop" 356 }, 357 { 358 "type": "null" 359 } 360 ], 361 "description": "A link to the cooling loop at the other end of the connection.", 362 "longDescription": "This property shall contain a link to a resource of type `CoolingLoop` that represents the cooling loop at the other end of the connection.", 363 "readonly": false 364 }, 365 "ConnectedCoolingUnit": { 366 "anyOf": [ 367 { 368 "$ref": "http://redfish.dmtf.org/schemas/v1/CoolingUnit.json#/definitions/CoolingUnit" 369 }, 370 { 371 "type": "null" 372 } 373 ], 374 "description": "A link to the cooling unit at the other end of the connection.", 375 "longDescription": "This property shall contain a link to a resource of type `CoolingUnit` that represents the cooling unit at the other end of the connection.", 376 "readonly": false 377 }, 378 "Oem": { 379 "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Oem", 380 "description": "The OEM extension property.", 381 "longDescription": "This property shall contain the OEM extensions. All values for properties contained in this object shall conform to the Redfish Specification-described requirements." 382 } 383 }, 384 "type": "object" 385 }, 386 "OemActions": { 387 "additionalProperties": true, 388 "description": "The available OEM-specific actions for this resource.", 389 "longDescription": "This type shall contain the available OEM-specific actions for this resource.", 390 "patternProperties": { 391 "^([a-zA-Z_][a-zA-Z0-9_]*)?@(odata|Redfish|Message)\\.[a-zA-Z_][a-zA-Z0-9_]*$": { 392 "description": "This property shall specify a valid odata or Redfish property.", 393 "type": [ 394 "array", 395 "boolean", 396 "integer", 397 "number", 398 "null", 399 "object", 400 "string" 401 ] 402 } 403 }, 404 "properties": {}, 405 "type": "object" 406 } 407 }, 408 "language": "en", 409 "owningEntity": "DMTF", 410 "release": "2023.1", 411 "title": "#CoolantConnector.v1_0_2.CoolantConnector" 412}