1<?xml version="1.0" encoding="UTF-8"?> 2<!----> 3<!--################################################################################ --> 4<!--# Redfish Schema: Outlet v1.4.4 --> 5<!--# --> 6<!--# For a detailed change log, see the README file contained in the DSP8010 bundle, --> 7<!--# available at http://www.dmtf.org/standards/redfish --> 8<!--# Copyright 2014-2024 DMTF. --> 9<!--# For the full DMTF copyright policy, see http://www.dmtf.org/about/policies/copyright --> 10<!--################################################################################ --> 11<!----> 12<edmx:Edmx xmlns:edmx="http://docs.oasis-open.org/odata/ns/edmx" Version="4.0"> 13 14 <edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Core.V1.xml"> 15 <edmx:Include Namespace="Org.OData.Core.V1" Alias="OData"/> 16 </edmx:Reference> 17 <edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Capabilities.V1.xml"> 18 <edmx:Include Namespace="Org.OData.Capabilities.V1" Alias="Capabilities"/> 19 </edmx:Reference> 20 <edmx:Reference Uri="http://docs.oasis-open.org/odata/odata/v4.0/errata03/csd01/complete/vocabularies/Org.OData.Measures.V1.xml"> 21 <edmx:Include Namespace="Org.OData.Measures.V1" Alias="Measures"/> 22 </edmx:Reference> 23 <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/RedfishExtensions_v1.xml"> 24 <edmx:Include Namespace="RedfishExtensions.v1_0_0" Alias="Redfish"/> 25 <edmx:Include Namespace="Validation.v1_0_0" Alias="Validation"/> 26 </edmx:Reference> 27 <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Resource_v1.xml"> 28 <edmx:Include Namespace="Resource"/> 29 <edmx:Include Namespace="Resource.v1_0_0"/> 30 </edmx:Reference> 31 <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Sensor_v1.xml"> 32 <edmx:Include Namespace="Sensor"/> 33 </edmx:Reference> 34 <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Circuit_v1.xml"> 35 <edmx:Include Namespace="Circuit"/> 36 </edmx:Reference> 37 <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/PowerSupply_v1.xml"> 38 <edmx:Include Namespace="PowerSupply"/> 39 </edmx:Reference> 40 <edmx:Reference Uri="http://redfish.dmtf.org/schemas/v1/Chassis_v1.xml"> 41 <edmx:Include Namespace="Chassis"/> 42 </edmx:Reference> 43 44 <edmx:DataServices> 45 46 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet"> 47 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 48 <Annotation Term="Redfish.Language" String="en"/> 49 50 <EntityType Name="Outlet" BaseType="Resource.v1_0_0.Resource" Abstract="true"> 51 <Annotation Term="OData.Description" String="The `Outlet` schema contains a definition for an electrical outlet."/> 52 <Annotation Term="OData.LongDescription" String="This resource shall be used to represent an electrical outlet for a Redfish implementation."/> 53 <Annotation Term="Capabilities.InsertRestrictions"> 54 <Record> 55 <PropertyValue Property="Insertable" Bool="false"/> 56 </Record> 57 </Annotation> 58 <Annotation Term="Capabilities.UpdateRestrictions"> 59 <Record> 60 <PropertyValue Property="Updatable" Bool="true"/> 61 <Annotation Term="OData.Description" String="Any writable properties can be updated."/> 62 </Record> 63 </Annotation> 64 <Annotation Term="Capabilities.DeleteRestrictions"> 65 <Record> 66 <PropertyValue Property="Deletable" Bool="false"/> 67 </Record> 68 </Annotation> 69 <Annotation Term="Redfish.Uris"> 70 <Collection> 71 <String>/redfish/v1/PowerEquipment/RackPDUs/{PowerDistributionId}/Outlets/{OutletId}</String> 72 <String>/redfish/v1/PowerEquipment/FloorPDUs/{PowerDistributionId}/Outlets/{OutletId}</String> 73 <String>/redfish/v1/PowerEquipment/TransferSwitches/{PowerDistributionId}/Outlets/{OutletId}</String> 74 <String>/redfish/v1/PowerEquipment/PowerShelves/{PowerDistributionId}/Outlets/{OutletId}</String> 75 <String>/redfish/v1/PowerEquipment/ElectricalBuses/{PowerDistributionId}/Outlets/{OutletId}</String> 76 </Collection> 77 </Annotation> 78 </EntityType> 79 80 <Action Name="PowerControl" IsBound="true"> 81 <Annotation Term="OData.Description" String="This action turns the outlet on or off."/> 82 <Annotation Term="OData.LongDescription" String="This action shall control the power state of the outlet."/> 83 <Parameter Name="Outlet" Type="Outlet.v1_0_0.Actions"/> 84 <Parameter Name="PowerState" Type="Circuit.PowerState"> 85 <Annotation Term="OData.Description" String="The desired power state of the outlet."/> 86 <Annotation Term="OData.LongDescription" String="This parameter shall contain the desired power state of the outlet."/> 87 </Parameter> 88 </Action> 89 90 <Action Name="ResetMetrics" IsBound="true"> 91 <Annotation Term="OData.Description" String="This action resets metrics related to this outlet."/> 92 <Annotation Term="OData.LongDescription" String="This action shall reset any time intervals or counted values for this outlet."/> 93 <Parameter Name="Outlet" Type="Outlet.v1_0_0.Actions"/> 94 </Action> 95 96 <EnumType Name="PowerState"> 97 <Member Name="On"> 98 <Annotation Term="OData.Description" String="Power on."/> 99 </Member> 100 <Member Name="Off"> 101 <Annotation Term="OData.Description" String="Power off."/> 102 </Member> 103 <Member Name="PowerCycle"> 104 <Annotation Term="OData.Description" String="Power cycle."/> 105 <Annotation Term="OData.LongDescription" String="This value shall indicate the resource will transition to a power off state, then transition to a power on state. Upon successful completion, the `PowerState` property, if supported, shall contain the value `On`."/> 106 <Annotation Term="Redfish.Revisions"> 107 <Collection> 108 <Record> 109 <PropertyValue Property="Kind" EnumMember="Redfish.RevisionKind/Added"/> 110 <PropertyValue Property="Version" String="v1_4_0"/> 111 </Record> 112 </Collection> 113 </Annotation> 114 </Member> 115 </EnumType> 116 117 <EnumType Name="ReceptacleType"> 118 <Member Name="NEMA_5_15R"> 119 <Annotation Term="OData.Description" String="NEMA 5-15R (120V; 15A)."/> 120 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the NEMA specified 5-15 receptacle (120V; 15A). The current is commonly de-rated to 12A if it is protected by a 15A breaker."/> 121 </Member> 122 <Member Name="NEMA_5_20R"> 123 <Annotation Term="OData.Description" String="NEMA 5-20R (120V; 20A)."/> 124 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the NEMA specified 5-20 receptacle that exhibits a T-slot (120V; 20A). The current is commonly de-rated to 16A if it is protected by a 20A breaker."/> 125 </Member> 126 <Member Name="NEMA_L5_20R"> 127 <Annotation Term="OData.Description" String="NEMA L5-20R (120V; 20A)."/> 128 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the NEMA specified locking L5-20 receptacle (120V; 20A). The current is commonly de-rated to 16A if it is protected by a 20A breaker."/> 129 </Member> 130 <Member Name="NEMA_L5_30R"> 131 <Annotation Term="OData.Description" String="NEMA L5-30R (120V; 30A)."/> 132 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the NEMA specified locking L5-30 receptacle (120V; 30A). The current is commonly de-rated to 24A if it is protected by a 30A breaker."/> 133 </Member> 134 <Member Name="NEMA_L6_20R"> 135 <Annotation Term="OData.Description" String="NEMA L6-20R (250V; 20A)."/> 136 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the NEMA specified locking L6-20 receptacle (250V; 20A). The current is commonly de-rated to 16A if it is protected by a 20A breaker."/> 137 </Member> 138 <Member Name="NEMA_L6_30R"> 139 <Annotation Term="OData.Description" String="NEMA L6-30R (250V; 30A)."/> 140 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the NEMA specified locking L6-30 receptacle (250V; 30A). The current is commonly de-rated to 24A if it is protected by a 30A breaker."/> 141 </Member> 142 <Member Name="IEC_60320_C13"> 143 <Annotation Term="OData.Description" String="IEC C13 (250V; 10A or 15A)."/> 144 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the IEC 60320 Sheet F C13 specified receptacle (250V; 10A per IEC, 15A per UL)."/> 145 </Member> 146 <Member Name="IEC_60320_C19"> 147 <Annotation Term="OData.Description" String="IEC C19 (250V; 16A or 20A)."/> 148 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the IEC 60320 Sheet J C19 specified receptacle (250V; 16A per IEC, 20A per UL)."/> 149 </Member> 150 <Member Name="CEE_7_Type_E"> 151 <Annotation Term="OData.Description" String="CEE 7/7 Type E (250V; 16A)."/> 152 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the French specified CEE 7/7 Type E receptacle (250V; 16A)."/> 153 </Member> 154 <Member Name="CEE_7_Type_F"> 155 <Annotation Term="OData.Description" String="CEE 7/7 Type F (250V; 16A)."/> 156 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the Schuko specified CEE 7/7 Type F receptacle (250V; 16A)."/> 157 </Member> 158 <Member Name="SEV_1011_TYPE_12"> 159 <Annotation Term="OData.Description" String="SEV 1011 Type 12 (250V; 10A)."/> 160 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the SEV 1011 specified Type 12 receptacle (250V; 10A)."/> 161 </Member> 162 <Member Name="SEV_1011_TYPE_23"> 163 <Annotation Term="OData.Description" String="SEV 1011 Type 23 (250V; 16A)."/> 164 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the SEV 1011 specified Type 23 receptacle (250V; 16A)."/> 165 </Member> 166 <Member Name="BS_1363_Type_G"> 167 <Annotation Term="OData.Description" String="BS 1363 Type G (250V; 13A)."/> 168 <Annotation Term="OData.LongDescription" String="This value shall represent a receptacle that matches the British BS 1363 Type G receptacle (250V; 13A)."/> 169 </Member> 170 <Member Name="BusConnection"> 171 <Annotation Term="OData.Description" String="Electrical bus connection."/> 172 <Annotation Term="OData.LongDescription" String="This value shall represent a direct connection to an electrical bus."/> 173 <Annotation Term="Redfish.Revisions"> 174 <Collection> 175 <Record> 176 <PropertyValue Property="Kind" EnumMember="Redfish.RevisionKind/Added"/> 177 <PropertyValue Property="Version" String="v1_3_0"/> 178 </Record> 179 </Collection> 180 </Annotation> 181 </Member> 182 </EnumType> 183 </Schema> 184 185 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_0_0"> 186 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 187 <Annotation Term="Redfish.Release" String="2019.4"/> 188 189 <EntityType Name="Outlet" BaseType="Outlet.Outlet"> 190 <Property Name="Status" Type="Resource.Status" Nullable="false"> 191 <Annotation Term="OData.Description" String="The status and health of the resource and its subordinate or dependent resources."/> 192 <Annotation Term="OData.LongDescription" String="This property shall contain any status or health properties of the resource."/> 193 </Property> 194 <Property Name="ElectricalContext" Type="Sensor.ElectricalContext"> 195 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 196 <Annotation Term="OData.Description" String="The combination of current-carrying conductors."/> 197 <Annotation Term="OData.LongDescription" String="This property shall contain the combination of current-carrying conductors that distribute power."/> 198 </Property> 199 <Property Name="PhaseWiringType" Type="Circuit.PhaseWiringType"> 200 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 201 <Annotation Term="OData.Description" String="The number of ungrounded current-carrying conductors (phases) and the total number of conductors (wires)."/> 202 <Annotation Term="OData.LongDescription" String="This property shall contain the number of ungrounded current-carrying conductors (phases) and the total number of conductors (wires)."/> 203 </Property> 204 <Property Name="VoltageType" Type="Outlet.v1_0_0.VoltageType"> 205 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 206 <Annotation Term="OData.Description" String="The type of voltage applied to the outlet."/> 207 <Annotation Term="OData.LongDescription" String="This property shall contain the type of voltage applied to the outlet."/> 208 </Property> 209 <Property Name="OutletType" Type="Outlet.ReceptacleType"> 210 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 211 <Annotation Term="OData.Description" String="The type of receptacle according to NEMA, IEC, or regional standards."/> 212 <Annotation Term="OData.LongDescription" String="This property shall contain the type of physical receptacle used for this outlet, as defined by IEC, NEMA, or regional standards."/> 213 </Property> 214 <Property Name="NominalVoltage" Type="Circuit.NominalVoltageType"> 215 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 216 <Annotation Term="OData.Description" String="The nominal voltage for this outlet."/> 217 <Annotation Term="OData.LongDescription" String="This property shall contain the nominal voltage for this outlet, in volt units."/> 218 </Property> 219 <Property Name="RatedCurrentAmps" Type="Edm.Decimal"> 220 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 221 <Annotation Term="OData.Description" String="The rated maximum current allowed for this outlet."/> 222 <Annotation Term="OData.LongDescription" String="This property shall contain the rated maximum current for this outlet, in ampere units, after any required de-rating, due to safety agency or other regulatory requirements, has been applied."/> 223 <Annotation Term="Measures.Unit" String="A"/> 224 <Annotation Term="Validation.Minimum" Int="0"/> 225 </Property> 226 <Property Name="IndicatorLED" Type="Resource.IndicatorLED"> 227 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 228 <Annotation Term="OData.Description" String="The state of the indicator LED, which identifies the outlet."/> 229 <Annotation Term="OData.LongDescription" String="This property shall contain the indicator light state for the indicator light associated with this outlet."/> 230 <Annotation Term="Redfish.Revisions"> 231 <Collection> 232 <Record> 233 <PropertyValue Property="Kind" EnumMember="Redfish.RevisionKind/Deprecated"/> 234 <PropertyValue Property="Version" String="v1_1_0"/> 235 <PropertyValue Property="Description" String="This property has been deprecated in favor of the `LocationIndicatorActive` property."/> 236 </Record> 237 </Collection> 238 </Annotation> 239 </Property> 240 <Property Name="PowerOnDelaySeconds" Type="Edm.Decimal"> 241 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 242 <Annotation Term="OData.Description" String="The number of seconds to delay power up after a power cycle or a `PowerControl` action. Zero seconds indicates no delay to power up."/> 243 <Annotation Term="OData.LongDescription" String="This property shall contain the number of seconds to delay power up after a power cycle or a `PowerControl` action. The value `0` shall indicate no delay to power up."/> 244 </Property> 245 <Property Name="PowerOffDelaySeconds" Type="Edm.Decimal"> 246 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 247 <Annotation Term="OData.Description" String="The number of seconds to delay power off after a `PowerControl` action. Zero seconds indicates no delay to power off."/> 248 <Annotation Term="OData.LongDescription" String="This property shall contain the number of seconds to delay power off after a `PowerControl` action. The value `0` shall indicate no delay to power off."/> 249 </Property> 250 <Property Name="PowerCycleDelaySeconds" Type="Edm.Decimal"> 251 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 252 <Annotation Term="OData.Description" String="The number of seconds to delay power on after a `PowerControl` action to cycle power. Zero seconds indicates no delay."/> 253 <Annotation Term="OData.LongDescription" String="This property shall contain the number of seconds to delay power on after a `PowerControl` action to cycle power. The value `0` shall indicate no delay to power on."/> 254 </Property> 255 <Property Name="PowerRestoreDelaySeconds" Type="Edm.Decimal"> 256 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 257 <Annotation Term="OData.Description" String="The number of seconds to delay power on after power has been restored. Zero seconds indicates no delay."/> 258 <Annotation Term="OData.LongDescription" String="This property shall contain the number of seconds to delay power on after a power fault. The value `0` shall indicate no delay to power on."/> 259 </Property> 260 <Property Name="PowerRestorePolicy" Type="Circuit.PowerRestorePolicyTypes" Nullable="false"> 261 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 262 <Annotation Term="OData.Description" String="The desired power state of the outlet when power is restored after a power loss."/> 263 <Annotation Term="OData.LongDescription" String="This property shall contain the desired `PowerState` of the outlet when power is applied. The value `LastState` shall return the outlet to the `PowerState` it was in when power was lost."/> 264 </Property> 265 <Property Name="PowerState" Type="Resource.PowerState"> 266 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 267 <Annotation Term="OData.Description" String="The power state of the outlet."/> 268 <Annotation Term="OData.LongDescription" String="This property shall contain the power state of the outlet."/> 269 </Property> 270 <Property Name="PowerEnabled" Type="Edm.Boolean"> 271 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 272 <Annotation Term="OData.Description" String="Indicates if the outlet can be powered."/> 273 <Annotation Term="OData.LongDescription" String="This property shall indicate the power enable state of the outlet. The value `true` shall indicate that the outlet can be powered on, and `false` shall indicate that the outlet cannot be powered."/> 274 </Property> 275 <NavigationProperty Name="Voltage" Type="Sensor.Sensor"> 276 <Annotation Term="Redfish.ExcerptCopy" String="Voltage"/> 277 <Annotation Term="OData.Description" String="The voltage (V) for this outlet."/> 278 <Annotation Term="OData.LongDescription" String="This property shall contain the voltage, in volt units, for this outlet. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Voltage`. This property shall not be present if `PhaseWiringType` contains a value that indicates a 4-wire or greater configuration, such as `TwoPhase4Wire`."/> 279 </NavigationProperty> 280 <NavigationProperty Name="CurrentAmps" Type="Sensor.Sensor"> 281 <Annotation Term="Redfish.ExcerptCopy" String="Current"/> 282 <Annotation Term="OData.Description" String="The current (A) for this outlet."/> 283 <Annotation Term="OData.LongDescription" String="This property shall contain the current, in ampere units, for this outlet. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Current`. This property shall not be present if `PhaseWiringType` contains a value that indicates a 4-wire or greater configuration, such as `TwoPhase4Wire`."/> 284 </NavigationProperty> 285 <NavigationProperty Name="PowerWatts" Type="Sensor.Sensor"> 286 <Annotation Term="Redfish.ExcerptCopy" String="Power"/> 287 <Annotation Term="OData.Description" String="The power (W) for this outlet."/> 288 <Annotation Term="OData.LongDescription" String="This property shall contain the total power, in watt units, for this outlet that represents the `Total` `ElectricalContext` sensor when multiple power sensors exist for this outlet. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Power`."/> 289 </NavigationProperty> 290 <NavigationProperty Name="EnergykWh" Type="Sensor.Sensor"> 291 <Annotation Term="Redfish.ExcerptCopy" String="EnergykWh"/> 292 <Annotation Term="OData.Description" String="The energy (kWh) for this outlet."/> 293 <Annotation Term="OData.LongDescription" String="This property shall contain the total energy, in kilowatt-hour units, for this outlet that represents the `Total` `ElectricalContext` sensor when multiple energy sensors exist for this outlet. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `EnergykWh`."/> 294 </NavigationProperty> 295 <NavigationProperty Name="FrequencyHz" Type="Sensor.Sensor"> 296 <Annotation Term="Redfish.ExcerptCopy"/> 297 <Annotation Term="OData.Description" String="The frequency (Hz) for this outlet."/> 298 <Annotation Term="OData.LongDescription" String="This property shall contain the frequency, in hertz units, for this outlet. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Frequency`."/> 299 </NavigationProperty> 300 301 <Property Name="PolyPhaseVoltage" Type="Outlet.v1_0_0.VoltageSensors"> 302 <Annotation Term="OData.Description" String="The voltage readings for this outlet."/> 303 <Annotation Term="OData.LongDescription" String="This property shall contain the voltage readings for this outlet. For 3-wire outlets, this property shall contain a duplicate copy of the voltage sensor referenced in the `Voltage` property, if present. For other outlets, this property should contain multiple voltage sensor readings used to fully describe the outlet."/> 304 </Property> 305 <Property Name="PolyPhaseCurrentAmps" Type="Outlet.v1_0_0.CurrentSensors"> 306 <Annotation Term="OData.Description" String="The current readings for this outlet."/> 307 <Annotation Term="OData.LongDescription" String="This property shall contain the current readings for this outlet. For 3-wire outlets, this property shall contain a duplicate copy of the current sensor referenced in the `CurrentAmps` property, if present. For other outlets, this property should contain multiple current sensor readings used to fully describe the outlet."/> 308 </Property> 309 310 <Property Name="Links" Type="Outlet.v1_0_0.Links" Nullable="false"> 311 <Annotation Term="OData.Description" String="The links to other resources that are related to this resource."/> 312 <Annotation Term="OData.LongDescription" String="This property shall contain links to resources that are related to but are not contained by, or subordinate to, this resource."/> 313 </Property> 314 <Property Name="Actions" Type="Outlet.v1_0_0.Actions" Nullable="false"> 315 <Annotation Term="OData.Description" String="The available actions for this resource."/> 316 <Annotation Term="OData.LongDescription" String="This property shall contain the available actions for this resource."/> 317 </Property> 318 </EntityType> 319 320 <ComplexType Name="Links" BaseType="Resource.Links"> 321 <Annotation Term="OData.Description" String="The links to other resources that are related to this resource."/> 322 <Annotation Term="OData.LongDescription" String="This Redfish Specification-described type shall contain links to resources that are related to but are not contained by, or subordinate to, this resource."/> 323 <NavigationProperty Name="BranchCircuit" Type="Circuit.Circuit"> 324 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 325 <Annotation Term="OData.Description" String="A reference to the branch circuit related to this outlet."/> 326 <Annotation Term="OData.LongDescription" String="This property shall contain a link to a resource of type `Circuit` that represent the branch circuit associated with this outlet."/> 327 <Annotation Term="OData.AutoExpandReferences"/> 328 </NavigationProperty> 329 </ComplexType> 330 331 <ComplexType Name="Actions"> 332 <Annotation Term="OData.AdditionalProperties" Bool="false"/> 333 <Annotation Term="OData.Description" String="The available actions for this resource."/> 334 <Annotation Term="OData.LongDescription" String="This type shall contain the available actions for this resource."/> 335 <Property Name="Oem" Type="Outlet.v1_0_0.OemActions" Nullable="false"> 336 <Annotation Term="OData.Description" String="The available OEM-specific actions for this resource."/> 337 <Annotation Term="OData.LongDescription" String="This property shall contain the available OEM-specific actions for this resource."/> 338 </Property> 339 </ComplexType> 340 341 <ComplexType Name="OemActions"> 342 <Annotation Term="OData.AdditionalProperties" Bool="true"/> 343 <Annotation Term="OData.Description" String="The available OEM-specific actions for this resource."/> 344 <Annotation Term="OData.LongDescription" String="This type shall contain the available OEM-specific actions for this resource."/> 345 </ComplexType> 346 347 <ComplexType Name="VoltageSensors"> 348 <Annotation Term="OData.AdditionalProperties" Bool="false"/> 349 <Annotation Term="OData.Description" String="The voltage readings for this outlet."/> 350 <Annotation Term="OData.LongDescription" String="This type shall contain properties that describe voltage sensor readings for an outlet."/> 351 <NavigationProperty Name="Line1ToLine2" Type="Sensor.Sensor"> 352 <Annotation Term="Redfish.ExcerptCopy" String="Voltage"/> 353 <Annotation Term="OData.Description" String="The Line 1 to Line 2 voltage (V) for this outlet."/> 354 <Annotation Term="OData.LongDescription" String="This property shall contain the line-to-line voltage, in volt units, between L1 and L2. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Voltage`. This property shall not be present if the equipment does not include an L1-L2 measurement."/> 355 </NavigationProperty> 356 <NavigationProperty Name="Line2ToLine3" Type="Sensor.Sensor"> 357 <Annotation Term="Redfish.ExcerptCopy" String="Voltage"/> 358 <Annotation Term="OData.Description" String="The Line 2 to Line 3 voltage (V) for this outlet."/> 359 <Annotation Term="OData.LongDescription" String="This property shall contain the line-to-line voltage, in volt units, between L2 and L3. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Voltage`. This property shall not be present if the equipment does not include an L2-L3 measurement."/> 360 </NavigationProperty> 361 <NavigationProperty Name="Line3ToLine1" Type="Sensor.Sensor"> 362 <Annotation Term="Redfish.ExcerptCopy" String="Voltage"/> 363 <Annotation Term="OData.Description" String="The Line 3 to Line 1 voltage (V) for this outlet."/> 364 <Annotation Term="OData.LongDescription" String="This property shall contain the line-to-line voltage, in volt units, between L3 and L1. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Voltage`. This property shall not be present if the equipment does not include an L3-L1 measurement."/> 365 </NavigationProperty> 366 <NavigationProperty Name="Line1ToNeutral" Type="Sensor.Sensor"> 367 <Annotation Term="Redfish.ExcerptCopy" String="Voltage"/> 368 <Annotation Term="OData.Description" String="The Line 1 to Neutral voltage (V) for this outlet."/> 369 <Annotation Term="OData.LongDescription" String="This property shall contain the line-to-line voltage, in volt units, between L1 and Neutral. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Voltage`. This property shall not be present if the equipment does not include an L1-Neutral measurement."/> 370 </NavigationProperty> 371 <NavigationProperty Name="Line2ToNeutral" Type="Sensor.Sensor"> 372 <Annotation Term="Redfish.ExcerptCopy" String="Voltage"/> 373 <Annotation Term="OData.Description" String="The Line 2 to Neutral voltage (V) for this outlet."/> 374 <Annotation Term="OData.LongDescription" String="This property shall contain the line-to-line voltage, in volt units, between L2 and Neutral. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Voltage`. This property shall not be present if the equipment does not include an L2-Neutral measurement."/> 375 </NavigationProperty> 376 <NavigationProperty Name="Line3ToNeutral" Type="Sensor.Sensor"> 377 <Annotation Term="Redfish.ExcerptCopy" String="Voltage"/> 378 <Annotation Term="OData.Description" String="The Line 3 to Neutral voltage (V) for this outlet."/> 379 <Annotation Term="OData.LongDescription" String="This property shall contain the line-to-line voltage, in volt units, between L3 and Neutral. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Voltage`. This property shall not be present if the equipment does not include an L3-Neutral measurement."/> 380 </NavigationProperty> 381 </ComplexType> 382 383 <ComplexType Name="CurrentSensors"> 384 <Annotation Term="OData.AdditionalProperties" Bool="false"/> 385 <Annotation Term="OData.Description" String="The current sensors for this outlet."/> 386 <Annotation Term="OData.LongDescription" String="This type shall contain properties that describe current sensor readings for an outlet."/> 387 <NavigationProperty Name="Line1" Type="Sensor.Sensor"> 388 <Annotation Term="Redfish.ExcerptCopy" String="Current"/> 389 <Annotation Term="OData.Description" String="Line 1 current (A)."/> 390 <Annotation Term="OData.LongDescription" String="This property shall contain the line current, in ampere units, for L1. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Current`. This property shall not be present if the equipment does not include an L1 measurement."/> 391 </NavigationProperty> 392 <NavigationProperty Name="Line2" Type="Sensor.Sensor"> 393 <Annotation Term="Redfish.ExcerptCopy" String="Current"/> 394 <Annotation Term="OData.Description" String="Line 2 current (A)."/> 395 <Annotation Term="OData.LongDescription" String="This property shall contain the line current, in ampere units, for L2. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Current`. This property shall not be present if the equipment does not include an L2 measurement."/> 396 </NavigationProperty> 397 <NavigationProperty Name="Line3" Type="Sensor.Sensor"> 398 <Annotation Term="Redfish.ExcerptCopy" String="Current"/> 399 <Annotation Term="OData.Description" String="Line 3 current (A)."/> 400 <Annotation Term="OData.LongDescription" String="This property shall contain the line current, in ampere units, for L3. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Current`. This property shall not be present if the equipment does not include an L3 measurement."/> 401 </NavigationProperty> 402 <NavigationProperty Name="Neutral" Type="Sensor.Sensor"> 403 <Annotation Term="Redfish.ExcerptCopy" String="Current"/> 404 <Annotation Term="OData.Description" String="Neutral line current (A)."/> 405 <Annotation Term="OData.LongDescription" String="This property shall contain the line current, in ampere units, for the Neutral line. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Current`. This property shall not be present if the equipment does not include a Neutral line measurement."/> 406 </NavigationProperty> 407 </ComplexType> 408 409 <EnumType Name="VoltageType"> 410 <Member Name="AC"> 411 <Annotation Term="OData.Description" String="Alternating Current (AC) outlet."/> 412 </Member> 413 <Member Name="DC"> 414 <Annotation Term="OData.Description" String="Direct Current (DC) outlet."/> 415 </Member> 416 </EnumType> 417 </Schema> 418 419 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_0_1"> 420 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 421 <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/> 422 <EntityType Name="Outlet" BaseType="Outlet.v1_0_0.Outlet"/> 423 </Schema> 424 425 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_0_2"> 426 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 427 <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/> 428 <EntityType Name="Outlet" BaseType="Outlet.v1_0_1.Outlet"/> 429 </Schema> 430 431 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_0_3"> 432 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 433 <Annotation Term="OData.Description" String="This version was created to update descriptions to tie excerpt property definitions to a specific type of `Sensor` or `Control` resource."/> 434 <EntityType Name="Outlet" BaseType="Outlet.v1_0_2.Outlet"/> 435 </Schema> 436 437 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_0_4"> 438 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 439 <Annotation Term="OData.Description" String="This version was created to update the `PowerState` parameter in the `PowerControl` action to reference the common enumeration in the `Circuit` schema."/> 440 <EntityType Name="Outlet" BaseType="Outlet.v1_0_3.Outlet"/> 441 </Schema> 442 443 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_0_5"> 444 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 445 <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/> 446 <EntityType Name="Outlet" BaseType="Outlet.v1_0_4.Outlet"/> 447 </Schema> 448 449 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_0_6"> 450 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 451 <Annotation Term="OData.Description" String="This version was created to force the regeneration of OpenAPI schemas to properly express nullable properties with external references. It was also created to correct various typographical errors."/> 452 <EntityType Name="Outlet" BaseType="Outlet.v1_0_5.Outlet"/> 453 </Schema> 454 455 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_0_7"> 456 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 457 <Annotation Term="OData.Description" String="This version was created to update the descriptions to explain voltage and current sensor properties in terms of the `PhaseWiringType`. It was also created to correct various typographic errors and for consistent style."/> 458 <EntityType Name="Outlet" BaseType="Outlet.v1_0_6.Outlet"/> 459 </Schema> 460 461 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_1_0"> 462 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 463 <Annotation Term="Redfish.Release" String="2020.3"/> 464 <Annotation Term="OData.Description" String="This version was created to deprecate `IndicatorLED` property in favor of `LocationIndicatorActive`."/> 465 466 <EntityType Name="Outlet" BaseType="Outlet.v1_0_1.Outlet"> 467 <Property Name="LocationIndicatorActive" Type="Edm.Boolean"> 468 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 469 <Annotation Term="OData.Description" String="An indicator allowing an operator to physically locate this resource."/> 470 <Annotation Term="OData.LongDescription" String="This property shall contain the state of the indicator used to physically identify or locate this resource. A write to this property shall update the value of `IndicatorLED` in this resource, if supported, to reflect the implementation of the locating function."/> 471 </Property> 472 </EntityType> 473 </Schema> 474 475 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_1_1"> 476 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 477 <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/> 478 <EntityType Name="Outlet" BaseType="Outlet.v1_1_0.Outlet"/> 479 </Schema> 480 481 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_1_2"> 482 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 483 <Annotation Term="OData.Description" String="This version was created to update descriptions to tie excerpt property definitions to a specific type of `Sensor` or `Control` resource."/> 484 <EntityType Name="Outlet" BaseType="Outlet.v1_1_1.Outlet"/> 485 </Schema> 486 487 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_1_3"> 488 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 489 <Annotation Term="OData.Description" String="This version was created to update the `PowerState` parameter in the `PowerControl` action to reference the common enumeration in the `Circuit` schema."/> 490 <EntityType Name="Outlet" BaseType="Outlet.v1_1_2.Outlet"/> 491 </Schema> 492 493 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_1_4"> 494 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 495 <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/> 496 <EntityType Name="Outlet" BaseType="Outlet.v1_1_3.Outlet"/> 497 </Schema> 498 499 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_1_5"> 500 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 501 <Annotation Term="OData.Description" String="This version was created to force the regeneration of OpenAPI schemas to properly express nullable properties with external references. It was also created to correct various typographical errors."/> 502 <EntityType Name="Outlet" BaseType="Outlet.v1_1_4.Outlet"/> 503 </Schema> 504 505 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_1_6"> 506 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 507 <Annotation Term="OData.Description" String="This version was created to update the descriptions to explain voltage and current sensor properties in terms of the `PhaseWiringType`. It was also created to correct various typographic errors and for consistent style."/> 508 <EntityType Name="Outlet" BaseType="Outlet.v1_1_5.Outlet"/> 509 </Schema> 510 511 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_2_0"> 512 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 513 <Annotation Term="Redfish.Release" String="2021.2"/> 514 515 <EntityType Name="Outlet" BaseType="Outlet.v1_1_1.Outlet"> 516 <NavigationProperty Name="PowerLoadPercent" Type="Sensor.Sensor"> 517 <Annotation Term="Redfish.ExcerptCopy"/> 518 <Annotation Term="OData.Description" String="The power load (percent) for this outlet."/> 519 <Annotation Term="OData.LongDescription" String="This property shall contain the power load, in percent units, for this outlet that represents the `Total` `ElectricalContext` for this outlet. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `Percent`."/> 520 </NavigationProperty> 521 </EntityType> 522 </Schema> 523 524 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_2_1"> 525 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 526 <Annotation Term="OData.Description" String="This version was created to update descriptions to tie excerpt property definitions to a specific type of `Sensor` or `Control` resource."/> 527 <EntityType Name="Outlet" BaseType="Outlet.v1_2_0.Outlet"/> 528 </Schema> 529 530 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_2_2"> 531 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 532 <Annotation Term="OData.Description" String="This version was created to update the `PowerState` parameter in the `PowerControl` action to reference the common enumeration in the `Circuit` schema."/> 533 <EntityType Name="Outlet" BaseType="Outlet.v1_2_1.Outlet"/> 534 </Schema> 535 536 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_2_3"> 537 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 538 <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/> 539 <EntityType Name="Outlet" BaseType="Outlet.v1_2_2.Outlet"/> 540 </Schema> 541 542 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_2_4"> 543 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 544 <Annotation Term="OData.Description" String="This version was created to force the regeneration of OpenAPI schemas to properly express nullable properties with external references. It was also created to correct various typographical errors."/> 545 <EntityType Name="Outlet" BaseType="Outlet.v1_2_3.Outlet"/> 546 </Schema> 547 548 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_2_5"> 549 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 550 <Annotation Term="OData.Description" String="This version was created to update the descriptions to explain voltage and current sensor properties in terms of the `PhaseWiringType`. It was also created to correct various typographic errors and for consistent style."/> 551 <EntityType Name="Outlet" BaseType="Outlet.v1_2_4.Outlet"/> 552 </Schema> 553 554 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_3_0"> 555 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 556 <Annotation Term="Redfish.Release" String="2021.3"/> 557 558 <EntityType Name="Outlet" BaseType="Outlet.v1_2_0.Outlet"> 559 <Property Name="ElectricalConsumerNames" Type="Collection(Edm.String)"> 560 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 561 <Annotation Term="OData.Description" String="An array of names of downstream devices that are powered by this outlet."/> 562 <Annotation Term="OData.LongDescription" String="This property shall contain an array of user-assigned identifying strings that describe downstream devices that are powered by this outlet."/> 563 </Property> 564 <Property Name="UserLabel" Type="Edm.String" Nullable="false"> 565 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 566 <Annotation Term="OData.Description" String="A user-assigned label."/> 567 <Annotation Term="OData.LongDescription" String="This property shall contain a user-assigned label used to identify this resource. If a value has not been assigned by a user, the value of this property shall be an empty string."/> 568 </Property> 569 </EntityType> 570 571 <ComplexType Name="Links" BaseType="Outlet.v1_0_0.Links"> 572 <NavigationProperty Name="DistributionCircuits" Type="Collection(Circuit.Circuit)"> 573 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 574 <Annotation Term="OData.Description" String="An array of links to mains or input circuits powered by this outlet."/> 575 <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources of type `Circuit` that represent the circuits powered by this outlet. This property is used to show a connection to an input circuit downstream in a power distribution chain."/> 576 <Annotation Term="OData.AutoExpandReferences"/> 577 </NavigationProperty> 578 <NavigationProperty Name="Chassis" Type="Collection(Chassis.Chassis)"> 579 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 580 <Annotation Term="OData.Description" String="Any array of links to chassis connected to this outlet."/> 581 <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources of type `Chassis` that represent the chassis connected to this outlet."/> 582 <Annotation Term="OData.AutoExpandReferences"/> 583 </NavigationProperty> 584 <NavigationProperty Name="PowerSupplies" Type="Collection(PowerSupply.PowerSupply)"> 585 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 586 <Annotation Term="OData.Description" String="An array of links to the power supplies connected to this outlet."/> 587 <Annotation Term="OData.LongDescription" String="This property shall contain an array of links to resources of type `PowerSupply` that represent the power supplies connected to this outlet."/> 588 <Annotation Term="OData.AutoExpandReferences"/> 589 </NavigationProperty> 590 </ComplexType> 591 </Schema> 592 593 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_3_1"> 594 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 595 <Annotation Term="OData.Description" String="This version was created to update descriptions to tie excerpt property definitions to a specific type of `Sensor` or `Control` resource."/> 596 <EntityType Name="Outlet" BaseType="Outlet.v1_3_0.Outlet"/> 597 </Schema> 598 599 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_3_2"> 600 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 601 <Annotation Term="OData.Description" String="This version was created to update the `PowerState` parameter in the `PowerControl` action to reference the common enumeration in the `Circuit` schema."/> 602 <EntityType Name="Outlet" BaseType="Outlet.v1_3_1.Outlet"/> 603 </Schema> 604 605 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_3_3"> 606 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 607 <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/> 608 <EntityType Name="Outlet" BaseType="Outlet.v1_3_2.Outlet"/> 609 </Schema> 610 611 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_3_4"> 612 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 613 <Annotation Term="OData.Description" String="This version was created to force the regeneration of OpenAPI schemas to properly express nullable properties with external references. It was also created to correct various typographical errors."/> 614 <EntityType Name="Outlet" BaseType="Outlet.v1_3_3.Outlet"/> 615 </Schema> 616 617 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_3_5"> 618 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 619 <Annotation Term="OData.Description" String="This version was created to update the descriptions to explain voltage and current sensor properties in terms of the `PhaseWiringType`. It was also created to correct various typographic errors and for consistent style."/> 620 <EntityType Name="Outlet" BaseType="Outlet.v1_3_4.Outlet"/> 621 </Schema> 622 623 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_4_0"> 624 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 625 <Annotation Term="Redfish.Release" String="2021.4"/> 626 <Annotation Term="OData.Description" String="This version was created to add `PowerCycle` to the `PowerState` parameter of the `PowerControl` action."/> 627 628 <EntityType Name="Outlet" BaseType="Outlet.v1_3_1.Outlet"> 629 <Property Name="PowerControlLocked" Type="Edm.Boolean" Nullable="false"> 630 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 631 <Annotation Term="OData.Description" String="Indicates whether power control requests are locked."/> 632 <Annotation Term="OData.LongDescription" String="This property shall indicate whether requests to the `PowerControl` action are locked. If `true`, services shall reject requests to the `PowerControl` action."/> 633 </Property> 634 <Property Name="ConfigurationLocked" Type="Edm.Boolean" Nullable="false"> 635 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/ReadWrite"/> 636 <Annotation Term="OData.Description" String="Indicates whether the configuration is locked."/> 637 <Annotation Term="OData.LongDescription" String="This property shall indicate whether modification requests to this resource are not permitted. If `true`, services shall reject modification requests to other properties in this resource."/> 638 </Property> 639 <Property Name="PowerStateInTransition" Type="Edm.Boolean" Nullable="false"> 640 <Annotation Term="OData.Permissions" EnumMember="OData.Permission/Read"/> 641 <Annotation Term="OData.Description" String="Indicates whether the power state is undergoing a delayed transition."/> 642 <Annotation Term="OData.LongDescription" String="This property shall indicate whether the `PowerState` property will undergo a transition between on and off states due to a configured delay. The transition may be due to the configuration of the power on, off, or restore delay properties. If `true`, the `PowerState` property will transition at the conclusion of a configured delay."/> 643 </Property> 644 </EntityType> 645 </Schema> 646 647 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_4_1"> 648 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 649 <Annotation Term="OData.Description" String="This version was created to update the `PowerState` parameter in the `PowerControl` action to reference the common enumeration in the `Circuit` schema."/> 650 <EntityType Name="Outlet" BaseType="Outlet.v1_4_0.Outlet"/> 651 </Schema> 652 653 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_4_2"> 654 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 655 <Annotation Term="OData.Description" String="This version was created to correct various typographical errors."/> 656 <EntityType Name="Outlet" BaseType="Outlet.v1_4_1.Outlet"/> 657 </Schema> 658 659 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_4_3"> 660 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 661 <Annotation Term="OData.Description" String="This version was created to force the regeneration of OpenAPI schemas to properly express nullable properties with external references. It was also created to correct various typographical errors."/> 662 <EntityType Name="Outlet" BaseType="Outlet.v1_4_2.Outlet"/> 663 </Schema> 664 665 <Schema xmlns="http://docs.oasis-open.org/odata/ns/edm" Namespace="Outlet.v1_4_4"> 666 <Annotation Term="Redfish.OwningEntity" String="DMTF"/> 667 <Annotation Term="OData.Description" String="This version was created to update the descriptions to explain voltage and current sensor properties in terms of the `PhaseWiringType`. It was also created to correct various typographic errors and for consistent style."/> 668 <EntityType Name="Outlet" BaseType="Outlet.v1_4_3.Outlet"/> 669 </Schema> 670 671 </edmx:DataServices> 672</edmx:Edmx> 673