1 /* 2 // Copyright (c) 2019 Intel Corporation 3 // 4 // Licensed under the Apache License, Version 2.0 (the "License"); 5 // you may not use this file except in compliance with the License. 6 // You may obtain a copy of the License at 7 // 8 // http://www.apache.org/licenses/LICENSE-2.0 9 // 10 // Unless required by applicable law or agreed to in writing, software 11 // distributed under the License is distributed on an "AS IS" BASIS, 12 // WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. 13 // See the License for the specific language governing permissions and 14 // limitations under the License. 15 */ 16 #pragma once 17 #include <registries.hpp> 18 19 namespace redfish::message_registries::openbmc 20 { 21 const Header header = { 22 "Copyright 2018 OpenBMC. All rights reserved.", 23 "#MessageRegistry.v1_4_0.MessageRegistry", 24 "OpenBMC.0.2.0", 25 "OpenBMC Message Registry", 26 "en", 27 "This registry defines the base messages for OpenBMC.", 28 "OpenBMC", 29 "0.2.0", 30 "OpenBMC", 31 }; 32 constexpr std::array<MessageEntry, 187> registry = { 33 MessageEntry{ 34 "ADDDCCorrectable", 35 { 36 "Indicates an ADDDC Correctable Error.", 37 "ADDDC Correctable Error.Socket=%1 Channel=%2 DIMM=%3 Rank=%4.", 38 "Warning", 39 "Warning", 40 4, 41 { 42 "number", 43 "string", 44 "number", 45 "number", 46 }, 47 "None.", 48 }}, 49 MessageEntry{ 50 "AtScaleDebugFeatureEnabledAtHardware", 51 { 52 "Indicates that At-Scale Debug enable is detected in hardware.", 53 "At-Scale Debug Feature is enabled in hardware.", 54 "Critical", 55 "Critical", 56 0, 57 {}, 58 "None.", 59 }}, 60 MessageEntry{ 61 "AtScaleDebugFeatureDisabledAtHardware", 62 { 63 "Indicates that At-Scale Debug disable is detected in hardware.", 64 "At-Scale Debug Feature is disabled in hardware.", 65 "OK", 66 "OK", 67 0, 68 {}, 69 "None.", 70 }}, 71 MessageEntry{"AtScaleDebugFeatureEnabled", 72 { 73 "Indicates that At-Scale Debug service is started.", 74 "At-Scale Debug service is started.", 75 "Critical", 76 "Critical", 77 0, 78 {}, 79 "None.", 80 }}, 81 MessageEntry{"AtScaleDebugFeatureDisabled", 82 { 83 "Indicates that At-Scale Debug service is stopped.", 84 "At-Scale Debug service is stopped.", 85 "OK", 86 "OK", 87 0, 88 {}, 89 "None.", 90 }}, 91 MessageEntry{"AtScaleDebugConnected", 92 { 93 "Indicates At-Scale Debug connection has been established", 94 "At-Scale Debug service is now connected %1", 95 "Critical", 96 "Critical", 97 1, 98 {"string"}, 99 "None.", 100 }}, 101 MessageEntry{"AtScaleDebugDisconnected", 102 { 103 "Indicates At-Scale Debug connection has ended", 104 "At-Scale Debug service is now disconnected", 105 "OK", 106 "OK", 107 0, 108 {}, 109 "None.", 110 }}, 111 MessageEntry{"AtScaleDebugConnectionFailed", 112 { 113 "Indicates At-Scale Debug connection aborted/failed", 114 "At-Scale Debug connection aborted/failed", 115 "Critical", 116 "Critical", 117 0, 118 {}, 119 "None.", 120 }}, 121 MessageEntry{"AtScaleDebugSpecialUserEnabled", 122 { 123 "Indicates that special user is enabled.", 124 "At-Scale Debug special user is enabled", 125 "Critical", 126 "Critical", 127 0, 128 {}, 129 "None.", 130 }}, 131 MessageEntry{"AtScaleDebugSpecialUserDisabled", 132 { 133 "Indicates that special user is disabled.", 134 "At-Scale Debug special user is disabled", 135 "OK", 136 "OK", 137 0, 138 {}, 139 "None.", 140 }}, 141 142 MessageEntry{ 143 "BIOSBoot", 144 { 145 "Indicates BIOS has transitioned control to the OS Loader.", 146 "BIOS System Boot.", 147 "OK", 148 "OK", 149 0, 150 {}, 151 "None.", 152 }}, 153 MessageEntry{"BIOSFirmwarePanicReason", 154 { 155 "Indicates the reason for BIOS firmware panic.", 156 "BIOS firmware panic occurred due to %1.", 157 "Warning", 158 "Warning", 159 1, 160 { 161 "string", 162 }, 163 "None.", 164 }}, 165 MessageEntry{"BIOSFirmwareRecoveryReason", 166 { 167 "Indicates the reason for BIOS firmware recovery.", 168 "BIOS firmware recovery occurred due to %1.", 169 "Warning", 170 "Warning", 171 1, 172 { 173 "string", 174 }, 175 "None.", 176 }}, 177 MessageEntry{"BIOSFirmwareResiliencyError", 178 { 179 "Indicates BIOS firmware encountered resilience error.", 180 "BIOS firmware resiliency error. Error reason: %1.", 181 "Critical", 182 "Critical", 183 1, 184 { 185 "string", 186 }, 187 "None.", 188 }}, 189 MessageEntry{ 190 "BIOSPOSTCode", 191 { 192 "BIOS Power-On Self-Test Code received", 193 "Boot Count: %1; Time Stamp Offset: %2 seconds; POST Code: %3", 194 "OK", 195 "OK", 196 3, 197 {"number", "number", "number"}, 198 "None.", 199 }}, 200 MessageEntry{"BIOSPOSTError", 201 { 202 "Indicates BIOS POST has encountered an error.", 203 "BIOS POST Error. Error Code=%1", 204 "Warning", 205 "Warning", 206 1, 207 {"number"}, 208 "None.", 209 }}, 210 MessageEntry{"BIOSRecoveryComplete", 211 { 212 "Indicates BIOS Recovery has completed.", 213 "BIOS Recovery Complete.", 214 "OK", 215 "OK", 216 0, 217 {}, 218 "None.", 219 }}, 220 MessageEntry{"BIOSRecoveryStart", 221 { 222 "Indicates BIOS Recovery has started.", 223 "BIOS Recovery Start.", 224 "Warning", 225 "Warning", 226 0, 227 {}, 228 "None.", 229 }}, 230 MessageEntry{"BMCBootReason", 231 { 232 "Indicates the reason why BMC firmware booted.", 233 "BMC firmware version %1 booted due to %2.", 234 "OK", 235 "OK", 236 2, 237 { 238 "string", 239 "string", 240 }, 241 "None.", 242 }}, 243 MessageEntry{"BMCFirmwarePanicReason", 244 { 245 "Indicates the reason for last BMC firmware panic.", 246 "BMC firmware panic occurred due to %1.", 247 "Warning", 248 "Warning", 249 1, 250 { 251 "string", 252 }, 253 "None.", 254 }}, 255 MessageEntry{"BMCFirmwareRecoveryReason", 256 { 257 "Indicates the reason for last BMC firmware recovery.", 258 "BMC firmware recovery occurred due to %1.", 259 "Warning", 260 "Warning", 261 1, 262 { 263 "string", 264 }, 265 "None.", 266 }}, 267 MessageEntry{"BMCFirmwareResiliencyError", 268 { 269 "Indicates BMC firmware encountered resilience error.", 270 "BMC firmware resiliency error. Error reason: %1.", 271 "Critical", 272 "Critical", 273 1, 274 { 275 "string", 276 }, 277 "None.", 278 }}, 279 MessageEntry{"BMCKernelPanic", 280 { 281 "Indicates that BMC kernel panic occurred.", 282 "BMC rebooted due to kernel panic.", 283 "OK", 284 "OK", 285 0, 286 {}, 287 "None.", 288 }}, 289 MessageEntry{"ChassisIntrusionDetected", 290 { 291 "Indicates that a physical security event " 292 "of the chassis intrusion has occurred.", 293 "Chassis Intrusion Detected.", 294 "Warning", 295 "Warning", 296 0, 297 {}, 298 "None.", 299 }}, 300 MessageEntry{"ChassisIntrusionReset", 301 { 302 "Indicates that chassis intrusion status has recovered.", 303 "Chassis Intrusion Reset.", 304 "OK", 305 "OK", 306 0, 307 {}, 308 "None.", 309 }}, 310 MessageEntry{"CPLDFirmwarePanicReason", 311 { 312 "Indicates the reason for CPLD firmware panic.", 313 "CPLD firmware panic occurred due to %1.", 314 "Warning", 315 "Warning", 316 1, 317 { 318 "string", 319 }, 320 "None.", 321 }}, 322 MessageEntry{"CPLDFirmwareRecoveryReason", 323 { 324 "Indicates the reason for CPLD firmware recovery.", 325 "CPLD firmware recovery occurred due to %1.", 326 "Warning", 327 "Warning", 328 1, 329 { 330 "string", 331 }, 332 "None.", 333 }}, 334 MessageEntry{"CPLDFirmwareResiliencyError", 335 { 336 "Indicates CPLD firmware encountered resilience error.", 337 "CPLD firmware resiliency error. Error reason: %1.", 338 "Critical", 339 "Critical", 340 1, 341 { 342 "string", 343 }, 344 "None.", 345 }}, 346 MessageEntry{"CPUError", 347 { 348 "Indicates that a CPU Error occurred of " 349 "the specified type or cause.", 350 "CPU Error Occurred: %1.", 351 "Critical", 352 "Critical", 353 1, 354 {"string"}, 355 "None.", 356 }}, 357 MessageEntry{"CPUMismatch", 358 { 359 "Indicates that the specified CPU power/current " 360 "rating is incompatible with the board.", 361 "CPU %1 Mismatch.", 362 "Critical", 363 "Critical", 364 1, 365 {"number"}, 366 "Install the supported CPU.", 367 }}, 368 MessageEntry{"CPUThermalTrip", 369 { 370 "Indicates that the specified CPU thermal " 371 "trip has been asserted.", 372 "CPU %1 Thermal Trip.", 373 "Critical", 374 "Critical", 375 1, 376 {"number"}, 377 "None.", 378 }}, 379 MessageEntry{"DCPowerOff", 380 { 381 "Indicates that the system DC power is off.", 382 "Host system DC power is off", 383 "OK", 384 "OK", 385 0, 386 {}, 387 "None.", 388 }}, 389 MessageEntry{"DCPowerOn", 390 { 391 "Indicates that the system DC power is on.", 392 "Host system DC power is on", 393 "OK", 394 "OK", 395 0, 396 {}, 397 "None.", 398 }}, 399 MessageEntry{"DriveError", 400 { 401 "Indicates that a Drive Error occurred of " 402 "the specified type or cause.", 403 "Drive Error Occurred: %1.", 404 "Warning", 405 "Warning", 406 1, 407 {"string"}, 408 "None.", 409 }}, 410 MessageEntry{"EventLogCleared", 411 { 412 "Indicates that the event log has been cleared.", 413 "Event Log Cleared.", 414 "OK", 415 "OK", 416 0, 417 {}, 418 "None.", 419 }}, 420 MessageEntry{"FanInserted", 421 { 422 "Indicates that a system fan has been inserted.", 423 "%1 inserted.", 424 "OK", 425 "OK", 426 1, 427 {"string"}, 428 "None.", 429 }}, 430 MessageEntry{"FanRedundancyLost", 431 { 432 "Indicates that system fan redundancy has been lost.", 433 "Fan redundancy lost.", 434 "Warning", 435 "Warning", 436 0, 437 {}, 438 "None.", 439 }}, 440 MessageEntry{"FanRedundancyRegained", 441 { 442 "Indicates that system fan redundancy has been regained.", 443 "Fan redundancy regained.", 444 "OK", 445 "OK", 446 0, 447 {}, 448 "None.", 449 }}, 450 MessageEntry{"FanRemoved", 451 { 452 "Indicates that a system fan has been removed.", 453 "%1 removed.", 454 "OK", 455 "OK", 456 1, 457 {"string"}, 458 "None.", 459 }}, 460 MessageEntry{ 461 "FirmwareActivationCompleted", 462 { 463 "Indicates a firmware activation has completed successfully.", 464 "%1 firmware activation completed successfully.", 465 "OK", 466 "OK", 467 1, 468 {"string"}, 469 "None.", 470 }}, 471 MessageEntry{"FirmwareActivationFailed", 472 { 473 "Indicates a firmware activation has failed.", 474 "%1 firmware activation failed: %2.", 475 "Warning", 476 "Warning", 477 2, 478 {"string", "string"}, 479 "None.", 480 }}, 481 MessageEntry{"FirmwareActivationStarted", 482 { 483 "Indicates a firmware activation has started.", 484 "%1 firmware activation started.", 485 "OK", 486 "OK", 487 1, 488 {"string"}, 489 "None.", 490 }}, 491 MessageEntry{"FirmwareUpdateCompleted", 492 { 493 "Indicates a firmware update has completed successfully.", 494 "%1 firmware update to version %2 completed " 495 "successfully.", 496 "OK", 497 "OK", 498 2, 499 {"string", "string"}, 500 "None.", 501 }}, 502 MessageEntry{"FirmwareUpdateFailed", 503 { 504 "Indicates a firmware update has failed.", 505 "%1 firmware update to version %2 failed: %3.", 506 "Warning", 507 "Warning", 508 3, 509 {"string", "string", "string"}, 510 "None.", 511 }}, 512 MessageEntry{"FirmwareUpdateStaged", 513 { 514 "Indicates a firmware update has staged successfully.", 515 "%1 firmware update to version %2 staged successfully.", 516 "OK", 517 "OK", 518 2, 519 {"string", "string"}, 520 "None.", 521 }}, 522 MessageEntry{"FirmwareUpdateStarted", 523 { 524 "Indicates a firmware update has started.", 525 "%1 firmware update to version %2 started.", 526 "OK", 527 "OK", 528 2, 529 {"string", "string"}, 530 "None.", 531 }}, 532 MessageEntry{ 533 "GeneralFirmwareSecurityViolation", 534 { 535 "Indicates a general firmware security violation has occurred.", 536 "Firmware security violation: %1.", 537 "Critical", 538 "Critical", 539 1, 540 {"string"}, 541 "None.", 542 }}, 543 MessageEntry{"InvalidLoginAttempted", 544 { 545 "Indicates that a login was attempted on the specified " 546 "interface with an invalid username or password.", 547 "Invalid username or password attempted on %1.", 548 "Warning", 549 "Warning", 550 1, 551 {"string"}, 552 "None.", 553 }}, 554 MessageEntry{"InvalidUpload", 555 { 556 "Indicates that the uploaded file was invalid.", 557 "Invalid file uploaded to %1: %2.", 558 "Warning", 559 "Warning", 560 2, 561 {"string", "string"}, 562 "None.", 563 }}, 564 MessageEntry{ 565 "InventoryAdded", 566 { 567 "Indicates that an inventory item with the specified model, " 568 "type, and serial number was installed.", 569 "%1 %2 with serial number %3 was installed.", 570 "OK", 571 "OK", 572 3, 573 574 { 575 "string", 576 "string", 577 "string", 578 }, 579 "None.", 580 }}, 581 MessageEntry{ 582 "InventoryRemoved", 583 { 584 "Indicates that an inventory item with the specified model, " 585 "type, and serial number was removed.", 586 "%1 %2 with serial number %3 was removed.", 587 "OK", 588 "OK", 589 3, 590 591 { 592 "string", 593 "string", 594 "string", 595 }, 596 "None.", 597 }}, 598 MessageEntry{ 599 "IntelUPILinkWidthReducedToHalf", 600 { 601 "Indicates Intel UPI link width has reduced to half width.", 602 "Intel UPI link width reduced to half. Node=%1.", 603 "Warning", 604 "Warning", 605 1, 606 607 { 608 "number", 609 }, 610 "None.", 611 }}, 612 MessageEntry{ 613 "IntelUPILinkWidthReducedToQuarter", 614 { 615 "Indicates Intel UPI link width has reduced to quarter width.", 616 "Intel UPI link width reduced to quarter. Node=%1.", 617 "Warning", 618 "Warning", 619 1, 620 621 { 622 "number", 623 }, 624 "None.", 625 }}, 626 627 MessageEntry{"IPMIWatchdog", 628 { 629 "Indicates that there is a host watchdog event.", 630 "Host Watchdog Event: %1", 631 "OK", 632 "OK", 633 1, 634 635 { 636 "string", 637 }, 638 "None.", 639 }}, 640 MessageEntry{"LanLost", 641 { 642 "Indicates that a physical security event " 643 "of the LAN leash has lost.", 644 "%1 LAN leash lost.", 645 "Warning", 646 "Warning", 647 1, 648 { 649 "string", 650 }, 651 "None.", 652 }}, 653 MessageEntry{"LanRegained", 654 { 655 "Indicates that LAN link status has reconnected.", 656 "%1 LAN leash regained.", 657 "OK", 658 "OK", 659 1, 660 { 661 "string", 662 }, 663 "None.", 664 }}, 665 MessageEntry{"LegacyPCIPERR", 666 { 667 "Indicates a Legacy PCI PERR.", 668 "Legacy PCI PERR. Bus=%1 Device=%2 Function=%3.", 669 "Warning", 670 "Warning", 671 3, 672 673 { 674 "number", 675 "number", 676 "number", 677 }, 678 "None.", 679 }}, 680 MessageEntry{"LegacyPCISERR", 681 { 682 "Indicates a Legacy PCI SERR.", 683 "Legacy PCI SERR. Bus=%1 Device=%2 Function=%3.", 684 "Critical", 685 "Critical", 686 3, 687 688 { 689 "number", 690 "number", 691 "number", 692 }, 693 "None.", 694 }}, 695 MessageEntry{"ManufacturingModeEntered", 696 { 697 "Indicates that the BMC entered Factory, " 698 "or Manufacturing mode.", 699 "Entered Manufacturing Mode.", 700 "Critical", 701 "Critical", 702 0, 703 {}, 704 "None.", 705 }}, 706 MessageEntry{"ManufacturingModeExited", 707 { 708 "Indicates that the BMC exited Factory, " 709 "or Manufacturing mode.", 710 "Exited Manufacturing Mode.", 711 "OK", 712 "OK", 713 0, 714 {}, 715 "None.", 716 }}, 717 MessageEntry{"MEAutoConfigFailed", 718 { 719 "Indicates that Intel ME power sensor " 720 "auto-configuration has failed.", 721 "Intel ME power sensor auto-configuration failed. Power " 722 "monitoring, limiting and HW protection features might " 723 "be unavailable. Failure reason: %1", 724 "Critical", 725 "Critical", 726 1, 727 {"string"}, 728 "Ensure that Intel ME configuration for power " 729 "sources is correct.", 730 }}, 731 MessageEntry{ 732 "MEAutoConfigSuccess", 733 { 734 "Indicates that Intel ME has performed successful " 735 "power sensor auto-configuration.", 736 "Intel ME power sensor auto-configuration succeeded. " 737 "Determined sources for domain readings are: DC Power: %1 ; " 738 "Chassis Power: %2 ; PSU Efficiency: %3 ; Unamanaged power: %4", 739 "OK", 740 "OK", 741 4, 742 {"string", "string", "string", "string"}, 743 "None.", 744 }}, 745 MessageEntry{"MEBootGuardHealthEvent", 746 { 747 "Indicates that Intel ME has detected error during " 748 "operations of Intel Boot Guard", 749 "Intel ME has detected following issue with Intel Boot " 750 "Guard: %1", 751 "Critical", 752 "Critical", 753 1, 754 {"string"}, 755 "None.", 756 }}, 757 MessageEntry{"MECpuDebugCapabilityDisabled", 758 { 759 "Indicates that Intel ME has detected situation in " 760 "which CPU Debug Capability is disabled.", 761 "CPU Debug Capability disabled", 762 "Warning", 763 "Warning", 764 0, 765 {}, 766 "None.", 767 }}, 768 MessageEntry{"MEDirectFlashUpdateRequested", 769 { 770 "Indicates that BIOS has requested Direct Flash " 771 "Update (DFU) of Intel ME", 772 "Intel ME Firmware switched to recovery mode to perform " 773 "full update from BIOS.", 774 "OK", 775 "OK", 776 0, 777 {}, 778 "This is transient state. Intel ME Firmware should " 779 "return to operational mode after successful image " 780 "update performed by the BIOS.", 781 }}, 782 MessageEntry{ 783 "MEExceptionDuringShutdown", 784 { 785 "Indicates that Intel ME could not successfully " 786 "perform emergency host shutdown.", 787 "Power Down command triggered by Intel Node Manager policy " 788 "failure action and Intel ME forced shutdown. BMC probably did " 789 "not respond correctly to Chassis Control.", 790 "Warning", 791 "Warning", 792 0, 793 {}, 794 "Verify the Intel Node Manager policy configuration.", 795 }}, 796 MessageEntry{ 797 "MEFactoryResetError", 798 { 799 "Indicates that Intel ME has ben restored to factory preset.", 800 "Intel ME has performed automatic reset to factory " 801 "presets due to following reason: %1", 802 "Critical", 803 "Critical", 804 1, 805 {"string"}, 806 "If error is persistent the Flash device must be replaced.", 807 }}, 808 MessageEntry{ 809 "MEFactoryRestore", 810 { 811 "Indicates that Intel ME has ben restored to factory preset.", 812 "Intel ME has performed automatic reset to factory " 813 "presets due to following reason: %1", 814 "OK", 815 "OK", 816 1, 817 {"string"}, 818 "If error is persistent the Flash device must be replaced.", 819 }}, 820 MessageEntry{ 821 "MEFirmwareException", 822 { 823 "Indicates that Intel ME has encountered firmware " 824 "exception during execution.", 825 "Intel ME has encountered firmware exception. Error code = %1", 826 "Warning", 827 "Warning", 828 1, 829 {"string"}, 830 "Restore factory presets using Force ME Recovery IPMI " 831 "command or by doing AC power cycle with Recovery jumper " 832 "asserted. If this does not clear the issue, reflash the SPI " 833 "flash. If the issue persists, provide the content of error " 834 "code to Intel support team for interpretation. (Error codes " 835 "are not documented because they only provide clues that must " 836 "be interpreted individually..", 837 }}, 838 MessageEntry{"MEFirmwarePanicReason", 839 { 840 "Indicates the reason for ME firmware panic.", 841 "ME firmware panic occurred due to %1.", 842 "Warning", 843 "Warning", 844 1, 845 { 846 "string", 847 }, 848 "None.", 849 }}, 850 MessageEntry{"MEFirmwareRecoveryReason", 851 { 852 "Indicates the reason for ME firmware recovery.", 853 "ME firmware recovery occurred due to %1.", 854 "Warning", 855 "Warning", 856 1, 857 { 858 "string", 859 }, 860 "None.", 861 }}, 862 MessageEntry{"MEFirmwareResiliencyError", 863 { 864 "Indicates ME firmware encountered resilience error.", 865 "ME firmware resiliency error. Error reason: %1.", 866 "Critical", 867 "Critical", 868 1, 869 { 870 "string", 871 }, 872 "None.", 873 }}, 874 875 MessageEntry{"MEFlashEraseError", 876 { 877 "Indicates that Intel ME was unable to finish flash " 878 "erase procedure.", 879 "Intel ME has encountered an error during Flash erasure " 880 "procedure probably due to Flash part corruption.", 881 "Critical", 882 "Critical", 883 0, 884 {}, 885 "The Flash device must be replaced.", 886 }}, 887 MessageEntry{"MEFlashStateInformation", 888 { 889 "Indicates that Intel ME has encountered a problem " 890 "during IO to flash device.", 891 "Intel ME has encountered problem during IO to flash " 892 "device. Reason: %1", 893 "Critical", 894 "Critical", 895 1, 896 {"string"}, 897 "If flash wear-out protection occurred wait until it " 898 "expires. Otherwise - flash device must be replaced.", 899 }}, 900 MessageEntry{"MEFlashStateInformationWritingEnabled", 901 { 902 "Indicates that Intel ME has encountered a problem " 903 "during IO to flash device.", 904 "Intel ME has encountered problem during IO to flash " 905 "device. Reason: %1", 906 "OK", 907 "OK", 908 1, 909 {"string"}, 910 "If flash wear-out protection occurred wait until it " 911 "expires. Otherwise - flash device must be replaced.", 912 }}, 913 MessageEntry{"MEFlashVerificationError", 914 { 915 "Indicates that Intel ME encountered invalid flash " 916 "descriptor region.", 917 "Intel ME has detected invalid flash descriptor region. " 918 "Following error is detected: %1", 919 "Critical", 920 "Critical", 921 1, 922 {"string"}, 923 "Flash Descriptor Region must be created correctly.", 924 }}, 925 MessageEntry{ 926 "MEFlashWearOutWarning", 927 { 928 "Indicates that Intel ME has reached certain " 929 "threshold of flash write operations.", 930 "Warning threshold for number of flash operations has been " 931 "exceeded. Current percentage of write operations capacity: %1", 932 "Warning", 933 "Warning", 934 1, 935 {"number"}, 936 "No immediate repair action needed.", 937 }}, 938 939 MessageEntry{ 940 "MEImageExecutionFailed", 941 { 942 "Indicates that Intel ME could not load primary FW image.", 943 "Intel ME Recovery Image or backup operational image " 944 "loaded because operational image is corrupted. This " 945 "may be either caused by Flash device corruption or " 946 "failed upgrade procedure.", 947 "Critical", 948 "Critical", 949 0, 950 {}, 951 "Either the Flash device must be replaced (if error is " 952 "persistent) or the upgrade procedure must be started again.", 953 }}, 954 955 MessageEntry{ 956 "MEInternalError", 957 { 958 "Indicates that Intel ME encountered " 959 "internal error leading to watchdog reset.", 960 "Error during Intel ME execution. Watchdog " 961 "timeout has expired.", 962 "Critical", 963 "Critical", 964 0, 965 {}, 966 "Firmware should automatically recover from error state. " 967 "If error is persistent then operational image shall be updated " 968 "or hardware board repair is needed.", 969 }}, 970 MessageEntry{"MEManufacturingError", 971 { 972 "Indicates that Intel ME is unable to start in " 973 "operational mode due to wrong configuration.", 974 "Wrong manufacturing configuration detected by Intel ME " 975 "Firmware. Unable to start operational mode. Reason: %1", 976 "Critical", 977 "Critical", 978 1, 979 {"string"}, 980 " If error is persistent the Flash device must be " 981 "replaced or FW configuration must be updated. Trace " 982 "logs might be gathered for detailed information.", 983 }}, 984 MessageEntry{"MEMctpInterfaceError", 985 { 986 "Indicates that Intel ME has encountered an error " 987 "in MCTP protocol.", 988 "Intel ME has detected MCTP interface failure and it is " 989 "not functional any more. It may indicate the situation " 990 "when MCTP was not configured by BIOS or a defect which " 991 "may need a Host reset to recover from. Details: %1", 992 "Critical", 993 "Critical", 994 1, 995 {"string"}, 996 "Recovery via CPU Host reset or platform reset. If error " 997 "is persistent, deep-dive platform-level debugging is " 998 "required.", 999 }}, 1000 MessageEntry{"MemoryECCCorrectable", 1001 { 1002 "Indicates a Correctable Memory ECC error.", 1003 "Memory ECC correctable error. Socket=%1 " 1004 "Channel=%2 DIMM=%3 Rank=%4.", 1005 "Warning", 1006 "Warning", 1007 4, 1008 1009 { 1010 "number", 1011 "string", 1012 "number", 1013 "number", 1014 }, 1015 "None.", 1016 }}, 1017 MessageEntry{"MemoryECCUncorrectable", 1018 { 1019 "Indicates an Uncorrectable Memory ECC error.", 1020 "Memory ECC uncorrectable error. Socket=%1 Channel=%2 " 1021 "DIMM=%3 Rank=%4.", 1022 "Critical", 1023 "Critical", 1024 4, 1025 1026 { 1027 "number", 1028 "string", 1029 "number", 1030 "number", 1031 }, 1032 "None.", 1033 }}, 1034 MessageEntry{"MemoryParityCommandAndAddress", 1035 { 1036 "Indicates a Command and Address parity error.", 1037 "Command and Address parity error. Socket=%1 Channel=%2 " 1038 "DIMM=%3 ChannelValid=%4 DIMMValid=%5.", 1039 "Critical", 1040 "Critical", 1041 5, 1042 1043 { 1044 "number", 1045 "string", 1046 "number", 1047 "number", 1048 "number", 1049 }, 1050 "None.", 1051 }}, 1052 MessageEntry{"MemoryParityNotKnown", 1053 { 1054 "Indicates an unknown parity error.", 1055 "Memory parity error. Socket=%1 Channel=%2 " 1056 "DIMM=%3 ChannelValid=%4 DIMMValid=%5.", 1057 "Critical", 1058 "Critical", 1059 5, 1060 1061 { 1062 "number", 1063 "string", 1064 "number", 1065 "number", 1066 "number", 1067 }, 1068 "None.", 1069 }}, 1070 MessageEntry{"MemoryRASConfigurationDisabled", 1071 { 1072 "Indicates Memory RAS Disabled Configuration Status.", 1073 "Memory RAS Configuration Disabled. Error=%1 Mode=%2.", 1074 "OK", 1075 "OK", 1076 2, 1077 1078 { 1079 "string", 1080 "string", 1081 }, 1082 "None.", 1083 }}, 1084 MessageEntry{"MemoryRASConfigurationEnabled", 1085 { 1086 "Indicates Memory RAS Enabled Configuration Status.", 1087 "Memory RAS Configuration Enabled. Error=%1 Mode=%2.", 1088 "OK", 1089 "OK", 1090 2, 1091 1092 { 1093 "string", 1094 "string", 1095 }, 1096 "None.", 1097 }}, 1098 MessageEntry{"MemoryRASModeDisabled", 1099 { 1100 "Indicates Memory RAS Disabled Mode Selection.", 1101 "Memory RAS Mode Select Disabled. Prior Mode=%1 " 1102 "Selected Mode=%2.", 1103 "OK", 1104 "OK", 1105 2, 1106 1107 { 1108 "string", 1109 "string", 1110 }, 1111 "None.", 1112 }}, 1113 MessageEntry{"MemoryRASModeEnabled", 1114 { 1115 "Indicates Memory RAS Enabled Mode Selection.", 1116 "Memory RAS Mode Select Enabled. Prior Mode=%1 Selected " 1117 "Mode=%2.", 1118 "OK", 1119 "OK", 1120 2, 1121 1122 { 1123 "string", 1124 "string", 1125 }, 1126 "None.", 1127 }}, 1128 MessageEntry{"MemoryThermTrip", 1129 { 1130 "Indicates that the system memory ThermTrip is asserted " 1131 "by the specified component.", 1132 "Memory ThermTrip asserted: %1.", 1133 "Critical", 1134 "Critical", 1135 1, 1136 {"string"}, 1137 "None.", 1138 }}, 1139 MessageEntry{"MEMultiPchModeMisconfig", 1140 { 1141 "Indicates that Intel ME has encountered " 1142 "problems in initializing Multi-PCH mode.", 1143 "Intel ME error in Multi-PCH mode: %1", 1144 "Critical", 1145 "Critical", 1146 1, 1147 {"string"}, 1148 "None.", 1149 }}, 1150 MessageEntry{ 1151 "MEPeciOverDmiError", 1152 { 1153 "Indicates that Intel ME is unable to communicate " 1154 "using PECI over DMI.", 1155 "Intel ME has detected PECI over DMI interface failure " 1156 "and it is not functional any more. It may indicate the " 1157 "situation when PECI over DMI was not configured by " 1158 "BIOS or a defect which may require a CPU Host reset to " 1159 "recover from. Details: %1", 1160 "Critical", 1161 "Critical", 1162 1, 1163 {"string"}, 1164 "Recovery via CPU Host reset or platform reset. If error is " 1165 "persistent, deep-dive platform-level debugging is required.", 1166 }}, 1167 MessageEntry{ 1168 "MEPttHealthEvent", 1169 { 1170 "Indicates that Intel ME has encountered issue with Intel PTT", 1171 "Intel ME has detected following issue with Intel PTT: %1", 1172 "Warning", 1173 "Warning", 1174 1, 1175 {"string"}, 1176 "None.", 1177 }}, 1178 MessageEntry{ 1179 "MERecoveryGpioForced", 1180 { 1181 "Indicates that Intel ME image is booted in " 1182 "recovery mode due to GPIO assertion.", 1183 "Intel ME Recovery Image loaded due to recovery MGPIO " 1184 "pin asserted. Pin number is configurable in factory " 1185 "presets, Default recovery pin is MGPIO1.", 1186 "OK", 1187 "OK", 1188 0, 1189 {}, 1190 "Deassert recovery GPIO and reset the Intel ME back to " 1191 "operational mode. If Recovery Jumper is in legacy behavior, " 1192 "a ME reset (eg. Cold Reset IPMI cmd) is needed to have ME " 1193 "back in operational mode.", 1194 }}, 1195 MessageEntry{"MERestrictedMode", 1196 { 1197 "Indicates events related to Intel ME restricted mode.", 1198 "Intel ME restricted mode information: %1", 1199 "Critical", 1200 "Critical", 1201 1, 1202 {"string"}, 1203 "None.", 1204 }}, 1205 MessageEntry{ 1206 "MESmbusLinkFailure", 1207 { 1208 "Indicate that Intel ME encountered SMBus link error.", 1209 "Intel ME has detected SMBus link error. " 1210 "Sensor Bus: %1 , MUX Address: %2 ", 1211 "Critical", 1212 "Critical", 1213 2, 1214 {"string", "string"}, 1215 "Devices connected to given SMLINK might cause communication " 1216 "corruption. See error code and refer to Intel ME External " 1217 "Interfaces Specification for details.", 1218 }}, 1219 MessageEntry{ 1220 "MEUmaError", 1221 { 1222 "Indicates that Intel ME has encountered UMA operation error.", 1223 "Intel ME has encountered UMA operation error. Details: %1", 1224 "Critical", 1225 "Critical", 1226 1, 1227 {"string"}, 1228 "Platform reset when UMA not configured correctly, or when " 1229 "error occurred during normal operation on correctly " 1230 "configured UMA multiple times leading to Intel ME entering " 1231 "Recovery or restricted operational mode.", 1232 }}, 1233 MessageEntry{"MEUnsupportedFeature", 1234 { 1235 "Indicates that Intel ME is configuration with " 1236 "feature which is not supported on this platform.", 1237 "Feature not supported in current segment detected by " 1238 "Intel ME Firmware. Details: %1", 1239 "Critical", 1240 "Critical", 1241 1, 1242 {"string"}, 1243 "Proper FW configuration must be updated or use the " 1244 "Flash device with proper FW configuration", 1245 }}, 1246 MessageEntry{"MirroringRedundancyDegraded", 1247 { 1248 "Indicates the mirroring redundancy state is degraded.", 1249 "Mirroring redundancy state degraded. Socket=%1 " 1250 "Channel=%2 DIMM=%3 Pair=%4 Rank=%5.", 1251 "Warning", 1252 "Warning", 1253 5, 1254 1255 { 1256 "number", 1257 "string", 1258 "number", 1259 "number", 1260 "number", 1261 }, 1262 "None.", 1263 }}, 1264 MessageEntry{ 1265 "MirroringRedundancyFull", 1266 { 1267 "Indicates the mirroring redundancy state is fully redundant.", 1268 "Mirroring redundancy state fully redundant. Socket=%1 " 1269 "Channel=%2 DIMM=%3 Pair=%4 Rank=%5.", 1270 "OK", 1271 "OK", 1272 5, 1273 1274 { 1275 "number", 1276 "string", 1277 "number", 1278 "number", 1279 "number", 1280 }, 1281 "None.", 1282 }}, 1283 MessageEntry{"NMIButtonPressed", 1284 { 1285 "Indicates that the NMI button was pressed.", 1286 "NMI Button Pressed.", 1287 "Critical", 1288 "Critical", 1289 0, 1290 {}, 1291 "None.", 1292 }}, 1293 MessageEntry{"NMIDiagnosticInterrupt", 1294 { 1295 "Indicates that an NMI Diagnostic " 1296 "Interrupt has been generated.", 1297 "NMI Diagnostic Interrupt.", 1298 "Critical", 1299 "Critical", 1300 0, 1301 {}, 1302 "None.", 1303 }}, 1304 MessageEntry{"PCIeCorrectableAdvisoryNonFatal", 1305 { 1306 "Indicates a PCIe Correctable Advisory Non-fatal Error.", 1307 "PCIe Correctable Advisory Non-fatal Error. Bus=%1 " 1308 "Device=%2 Function=%3.", 1309 "Warning", 1310 "Warning", 1311 3, 1312 1313 { 1314 "number", 1315 "number", 1316 "number", 1317 }, 1318 "None.", 1319 }}, 1320 MessageEntry{"PCIeCorrectableBadDLLP", 1321 { 1322 "Indicates a PCIe Correctable Bad DLLP Error.", 1323 1324 "PCIe Correctable Bad DLLP. Bus=%1 Device=%2 Function=%3.", 1325 "Warning", 1326 "Warning", 1327 3, 1328 1329 { 1330 "number", 1331 "number", 1332 "number", 1333 }, 1334 "None.", 1335 }}, 1336 MessageEntry{"PCIeCorrectableBadTLP", 1337 { 1338 "Indicates a PCIe Correctable Bad TLP Error.", 1339 1340 "PCIe Correctable Bad TLP. Bus=%1 Device=%2 Function=%3.", 1341 "Warning", 1342 "Warning", 1343 3, 1344 1345 { 1346 "number", 1347 "number", 1348 "number", 1349 }, 1350 "None.", 1351 }}, 1352 MessageEntry{"PCIeCorrectableHeaderLogOverflow", 1353 { 1354 "Indicates a PCIe Correctable Header Log Overflow Error.", 1355 "PCIe Correctable Header Log Overflow. Bus=%1 Device=%2 " 1356 "Function=%3.", 1357 "Warning", 1358 "Warning", 1359 3, 1360 1361 { 1362 "number", 1363 "number", 1364 "number", 1365 }, 1366 "None.", 1367 }}, 1368 MessageEntry{"PCIeCorrectableInternal", 1369 { 1370 "Indicates a PCIe Correctable Internal Error.", 1371 "PCIe Correctable Internal Error. Bus=%1 Device=%2 " 1372 "Function=%3.", 1373 "Warning", 1374 "Warning", 1375 3, 1376 1377 { 1378 "number", 1379 "number", 1380 "number", 1381 }, 1382 "None.", 1383 }}, 1384 MessageEntry{"PCIeCorrectableLinkBWChanged", 1385 { 1386 "Indicates a PCIe Correctable Link BW Changed Error.", 1387 "PCIe Correctable Link BW Changed. Bus=%1 " 1388 "Device=%2 Function=%3.", 1389 "Warning", 1390 "Warning", 1391 3, 1392 1393 { 1394 "number", 1395 "number", 1396 "number", 1397 }, 1398 "None.", 1399 }}, 1400 MessageEntry{"PCIeCorrectableReceiverError", 1401 { 1402 "Indicates a PCIe Correctable Receiver Error.", 1403 "PCIe Correctable Receiver Error. Bus=%1 Device=%2 " 1404 "Function=%3.", 1405 "Warning", 1406 "Warning", 1407 3, 1408 1409 { 1410 "number", 1411 "number", 1412 "number", 1413 }, 1414 "None.", 1415 }}, 1416 MessageEntry{"PCIeCorrectableReplayNumRollover", 1417 { 1418 "Indicates a PCIe Correctable Replay Num Rollover.", 1419 "PCIe Correctable Replay Num Rollover. Bus=%1 Device=%2 " 1420 "Function=%3.", 1421 "Warning", 1422 "Warning", 1423 3, 1424 1425 { 1426 "number", 1427 "number", 1428 "number", 1429 }, 1430 "None.", 1431 }}, 1432 MessageEntry{"PCIeCorrectableReplayTimerTimeout", 1433 { 1434 "Indicates a PCIe Correctable Replay Timer Timeout.", 1435 "PCIe Correctable Replay Timer Timeout. Bus=%1 " 1436 "Device=%2 Function=%3.", 1437 "Warning", 1438 "Warning", 1439 3, 1440 1441 { 1442 "number", 1443 "number", 1444 "number", 1445 }, 1446 "None.", 1447 }}, 1448 MessageEntry{"PCIeCorrectableUnspecifiedAERError", 1449 { 1450 "Indicates a PCIe Correctable Unspecified AER Error.", 1451 "PCIe Correctable Unspecified AER Error. " 1452 "Bus=%1 Device=%2 Function=%3.", 1453 "Warning", 1454 "Warning", 1455 3, 1456 1457 { 1458 "number", 1459 "number", 1460 "number", 1461 }, 1462 "None.", 1463 }}, 1464 MessageEntry{"PCIeFatalACSViolation", 1465 { 1466 "Indicates a PCIe ACS Violation Error.", 1467 1468 "PCIe Fatal ACS Violation. Bus=%1 Device=%2 Function=%3.", 1469 "Critical", 1470 "Critical", 1471 3, 1472 1473 { 1474 "number", 1475 "number", 1476 "number", 1477 }, 1478 "None.", 1479 }}, 1480 MessageEntry{"PCIeFatalAtomicEgressBlocked", 1481 { 1482 "Indicates a PCIe Atomic Egress Blocked Error.", 1483 "PCIe Fatal Atomic Egress Blocked. Bus=%1 Device=%2 " 1484 "Function=%3.", 1485 "Critical", 1486 "Critical", 1487 3, 1488 1489 { 1490 "number", 1491 "number", 1492 "number", 1493 }, 1494 "None.", 1495 }}, 1496 MessageEntry{ 1497 "PCIeFatalCompleterAbort", 1498 { 1499 "Indicates a PCIe Completer Abort Error.", 1500 1501 "PCIe Fatal Completer Abort. Bus=%1 Device=%2 Function=%3.", 1502 "Critical", 1503 "Critical", 1504 3, 1505 1506 { 1507 "number", 1508 "number", 1509 "number", 1510 }, 1511 "None.", 1512 }}, 1513 MessageEntry{ 1514 "PCIeFatalCompletionTimeout", 1515 { 1516 "Indicates a PCIe Completion Timeout Error.", 1517 1518 "PCIe Fatal Completion Timeout. Bus=%1 Device=%2 Function=%3.", 1519 "Critical", 1520 "Critical", 1521 3, 1522 1523 { 1524 "number", 1525 "number", 1526 "number", 1527 }, 1528 "None.", 1529 }}, 1530 MessageEntry{ 1531 "PCIeFatalDataLinkLayerProtocol", 1532 { 1533 "Indicates a PCIe Data Link Layer Protocol Error.", 1534 1535 "PCIe Fatal Data Link Layer Protocol Error. Bus=%1 Device=%2 " 1536 "Function=%3.", 1537 "Critical", 1538 "Critical", 1539 3, 1540 1541 { 1542 "number", 1543 "number", 1544 "number", 1545 }, 1546 "None.", 1547 }}, 1548 MessageEntry{"PCIeFatalECRCError", 1549 { 1550 "Indicates a PCIe ECRC Error.", 1551 "PCIe Fatal ECRC Error. Bus=%1 Device=%2 Function=%3.", 1552 "Critical", 1553 "Critical", 1554 3, 1555 1556 { 1557 "number", 1558 "number", 1559 "number", 1560 }, 1561 "None.", 1562 }}, 1563 MessageEntry{"PCIeFatalFlowControlProtocol", 1564 { 1565 "Indicates a PCIe Flow Control Protocol Error.", 1566 1567 "PCIe Fatal Flow Control Protocol Error. Bus=%1 Device=%2 " 1568 "Function=%3.", 1569 "Critical", 1570 "Critical", 1571 3, 1572 1573 { 1574 "number", 1575 "number", 1576 "number", 1577 }, 1578 "None.", 1579 }}, 1580 MessageEntry{ 1581 "PCIeFatalMalformedTLP", 1582 { 1583 "Indicates a PCIe Malformed TLP Error.", 1584 1585 "PCIe Fatal Malformed TLP Error. Bus=%1 Device=%2 Function=%3.", 1586 "Critical", 1587 "Critical", 1588 3, 1589 1590 { 1591 "number", 1592 "number", 1593 "number", 1594 }, 1595 "None.", 1596 }}, 1597 MessageEntry{"PCIeFatalMCBlockedTLP", 1598 { 1599 "Indicates a PCIe MC Blocked TLP Error.", 1600 "PCIe Fatal MC Blocked TLP Error. Bus=%1 " 1601 "Device=%2 Function=%3.", 1602 "Critical", 1603 "Critical", 1604 3, 1605 1606 { 1607 "number", 1608 "number", 1609 "number", 1610 }, 1611 "None.", 1612 }}, 1613 MessageEntry{ 1614 "PCIeFatalPoisonedTLP", 1615 { 1616 "Indicates a PCIe Poisoned TLP Error.", 1617 1618 "PCIe Fatal Poisoned TLP Error. Bus=%1 Device=%2 Function=%3.", 1619 "Critical", 1620 "Critical", 1621 3, 1622 1623 { 1624 "number", 1625 "number", 1626 "number", 1627 }, 1628 "None.", 1629 }}, 1630 MessageEntry{"PCIeFatalReceiverBufferOverflow", 1631 { 1632 "Indicates a PCIe Receiver Buffer Overflow Error.", 1633 "PCIe Fatal Receiver Buffer Overflow. Bus=%1 Device=%2 " 1634 "Function=%3.", 1635 "Critical", 1636 "Critical", 1637 3, 1638 1639 { 1640 "number", 1641 "number", 1642 "number", 1643 }, 1644 "None.", 1645 }}, 1646 MessageEntry{ 1647 "PCIeFatalReceivedErrNonFatalMessage", 1648 { 1649 "Indicates a PCIe Received ERR_NONFATAL Message Error.", 1650 1651 "PCIe Fatal Received ERR_NONFATAL Message. Bus=%1 Device=%2 " 1652 "Function=%3.", 1653 "Critical", 1654 "Critical", 1655 3, 1656 1657 { 1658 "number", 1659 "number", 1660 "number", 1661 }, 1662 "None.", 1663 }}, 1664 MessageEntry{"PCIeFatalReceivedFatalMessageFromDownstream", 1665 { 1666 "Indicates a PCIe Received Fatal Message " 1667 "From Downstream Error.", 1668 1669 "PCIe Fatal Received Fatal Message From Downstream. " 1670 "Bus=%1 Device=%2 Function=%3.", 1671 "Critical", 1672 "Critical", 1673 3, 1674 1675 { 1676 "number", 1677 "number", 1678 "number", 1679 }, 1680 "None.", 1681 }}, 1682 MessageEntry{"PCIeFatalSurpriseLinkDown", 1683 { 1684 "Indicates a PCIe Surprise Link Down Error.", 1685 "PCIe Fatal Surprise Link Down Error. Bus=%1 Device=%2 " 1686 "Function=%3.", 1687 "Critical", 1688 "Critical", 1689 3, 1690 1691 { 1692 "number", 1693 "number", 1694 "number", 1695 }, 1696 "None.", 1697 }}, 1698 MessageEntry{"PCIeFatalTLPPrefixBlocked", 1699 { 1700 "Indicates a PCIe TLP Prefix Blocked Error.", 1701 "PCIe Fatal TLP Prefix Blocked Error. Bus=%1 Device=%2 " 1702 "Function=%3.", 1703 "Critical", 1704 "Critical", 1705 3, 1706 1707 { 1708 "number", 1709 "number", 1710 "number", 1711 }, 1712 "None.", 1713 }}, 1714 MessageEntry{ 1715 "PCIeFatalUncorrectableInternal", 1716 { 1717 "Indicates a PCIe Uncorrectable Internal Error.", 1718 1719 "PCIe Fatal Uncorrectable Internal Error. Bus=%1 Device=%2 " 1720 "Function=%3.", 1721 "Critical", 1722 "Critical", 1723 3, 1724 1725 { 1726 "number", 1727 "number", 1728 "number", 1729 }, 1730 "None.", 1731 }}, 1732 MessageEntry{"PCIeFatalUnexpectedCompletion", 1733 { 1734 "Indicates a PCIe Unexpected Completion Error.", 1735 "PCIe Fatal Unexpected Completion. Bus=%1 Device=%2 " 1736 "Function=%3.", 1737 "Critical", 1738 "Critical", 1739 3, 1740 1741 { 1742 "number", 1743 "number", 1744 "number", 1745 }, 1746 "None.", 1747 }}, 1748 MessageEntry{"PCIeFatalUnspecifiedNonAERFatalError", 1749 { 1750 "Indicates a PCIe Unspecified Non-AER Fatal Error.", 1751 "PCIe Fatal Unspecified Non-AER Fatal Error. Bus=%1 " 1752 "Device=%2 Function=%3.", 1753 "Critical", 1754 "Critical", 1755 3, 1756 1757 { 1758 "number", 1759 "number", 1760 "number", 1761 }, 1762 "None.", 1763 }}, 1764 MessageEntry{ 1765 "PCIeFatalUnsupportedRequest", 1766 { 1767 "Indicates a PCIe Unsupported Request Error.", 1768 1769 "PCIe Fatal Unsupported Request. Bus=%1 Device=%2 Function=%3.", 1770 "Critical", 1771 "Critical", 1772 3, 1773 1774 { 1775 "number", 1776 "number", 1777 "number", 1778 }, 1779 "None.", 1780 }}, 1781 MessageEntry{"PowerButtonPressed", 1782 { 1783 "Indicates that the power button was pressed.", 1784 "Power Button Pressed.", 1785 "OK", 1786 "OK", 1787 0, 1788 {}, 1789 "None.", 1790 }}, 1791 MessageEntry{"PowerRestorePolicyApplied", 1792 { 1793 "Indicates that power was restored and the " 1794 "BMC has applied the restore policy.", 1795 "Power restore policy applied.", 1796 "OK", 1797 "OK", 1798 0, 1799 {}, 1800 "None.", 1801 }}, 1802 MessageEntry{"PowerSupplyConfigurationError", 1803 { 1804 "Indicates an error in power supply configuration.", 1805 "Power supply %1 configuration error.", 1806 "Warning", 1807 "Warning", 1808 1, 1809 {"string"}, 1810 "None.", 1811 }}, 1812 MessageEntry{ 1813 "PowerSupplyConfigurationErrorRecovered", 1814 { 1815 "Indicates that power supply configuration error recovered " 1816 "from a failure.", 1817 "Power supply %1 configuration error recovered.", 1818 "OK", 1819 "OK", 1820 1, 1821 {"string"}, 1822 "None.", 1823 }}, 1824 MessageEntry{ 1825 "PowerSupplyFanFailed", 1826 { 1827 "Indicates that the specified power supply fan has failed.", 1828 "Power supply %1 fan %2 failed.", 1829 "Warning", 1830 "Warning", 1831 2, 1832 {"string", "string"}, 1833 "None.", 1834 }}, 1835 MessageEntry{ 1836 "PowerSupplyFanRecovered", 1837 { 1838 "Indicates that the power supply fan recovered from a failure.", 1839 "Power supply %1 fan %2 recovered.", 1840 "OK", 1841 "OK", 1842 2, 1843 {"string", "string"}, 1844 "None.", 1845 }}, 1846 MessageEntry{"PowerSupplyFailed", 1847 { 1848 "Indicates that a power supply has failed.", 1849 "Power supply %1 failed.", 1850 "Warning", 1851 "Warning", 1852 1, 1853 {"string"}, 1854 "None.", 1855 }}, 1856 MessageEntry{"PowerSupplyFailurePredicted", 1857 { 1858 "Indicates that a power supply is predicted to fail.", 1859 "Power supply %1 failure predicted.", 1860 "Warning", 1861 "Warning", 1862 1, 1863 {"string"}, 1864 "None.", 1865 }}, 1866 MessageEntry{"PowerSupplyInserted", 1867 { 1868 "Indicates that a power supply has been inserted.", 1869 "Power supply %1 inserted.", 1870 "OK", 1871 "OK", 1872 1, 1873 {"string"}, 1874 "None.", 1875 }}, 1876 MessageEntry{"PowerSupplyPowerGoodFailed", 1877 { 1878 "Indicates that the power supply power good signal " 1879 "failed to assert within the specified time.", 1880 "Power supply power good failed to assert within %1 " 1881 "milliseconds.", 1882 "Critical", 1883 "Critical", 1884 1, 1885 {"number"}, 1886 "None.", 1887 }}, 1888 MessageEntry{"PowerSupplyPowerLost", 1889 { 1890 "Indicates that a power supply has lost input power.", 1891 "Power supply %1 power lost.", 1892 "Warning", 1893 "Warning", 1894 1, 1895 {"string"}, 1896 "None.", 1897 }}, 1898 MessageEntry{"PowerSupplyPowerRestored", 1899 { 1900 "Indicates that a power supply input power was restored.", 1901 "Power supply %1 power restored.", 1902 "OK", 1903 "OK", 1904 1, 1905 {"string"}, 1906 "None.", 1907 }}, 1908 MessageEntry{"PowerSupplyPredictedFailureRecovered", 1909 { 1910 "Indicates that a power supply recovered " 1911 "from a predicted failure.", 1912 "Power supply %1 predicted failure recovered.", 1913 "OK", 1914 "OK", 1915 1, 1916 {"string"}, 1917 "None.", 1918 }}, 1919 MessageEntry{"PowerSupplyRecovered", 1920 { 1921 "Indicates that a power supply recovered from a failure.", 1922 "Power supply %1 recovered.", 1923 "OK", 1924 "OK", 1925 1, 1926 {"string"}, 1927 "None.", 1928 }}, 1929 MessageEntry{"PowerSupplyRemoved", 1930 { 1931 "Indicates that a power supply has been removed.", 1932 "Power supply %1 removed.", 1933 "Warning", 1934 "Warning", 1935 1, 1936 {"string"}, 1937 "None.", 1938 }}, 1939 MessageEntry{"PowerUnitDegradedFromNonRedundant", 1940 { 1941 "Indicates that power unit is come back to redundant from" 1942 "nonredundant but is still not in full redundancy mode.", 1943 "Power Unit degraded from nonredundant.", 1944 "Warning", 1945 "Warning", 1946 0, 1947 {}, 1948 "None.", 1949 }}, 1950 MessageEntry{"PowerUnitDegradedFromRedundant", 1951 { 1952 "Indicates that power unit is degarded from full " 1953 "redundancy mode.", 1954 "Power Unit degraded from redundant.", 1955 "Warning", 1956 "Warning", 1957 0, 1958 {}, 1959 "None.", 1960 }}, 1961 MessageEntry{"PowerUnitRedundancyDegraded", 1962 { 1963 "Indicates that power unit redundancy has been degraded.", 1964 "Power Unit Redundancy degraded.", 1965 "Warning", 1966 "Warning", 1967 0, 1968 {}, 1969 "None.", 1970 }}, 1971 MessageEntry{ 1972 "PowerUnitNonRedundantFromInsufficient", 1973 { 1974 "Indicates that power unit is not in redundancy mode and get" 1975 "sufficient power to support redundancy from insufficient" 1976 "power.", 1977 1978 "Power Unit NonRedundant from insufficient to sufficient.", 1979 "Warning", 1980 "Warning", 1981 0, 1982 {}, 1983 "None.", 1984 }}, 1985 MessageEntry{"PowerUnitNonRedundantInsufficient", 1986 { 1987 "Indicates that power unit do not have sufficient " 1988 "power to support redundancy.", 1989 "Power Unit NonRedundant and has insufficient resource.", 1990 "Critical", 1991 "Critical", 1992 0, 1993 {}, 1994 "None.", 1995 }}, 1996 MessageEntry{"PowerUnitRedundancyLost", 1997 { 1998 "Indicates that power unit redundancy has been lost.", 1999 "Power Unit Redundancy lost.", 2000 "Warning", 2001 "Warning", 2002 0, 2003 {}, 2004 "None.", 2005 }}, 2006 MessageEntry{ 2007 "PowerUnitRedundancyRegained", 2008 { 2009 "Indicates that power unit full redundancy has been regained.", 2010 "Power Unit Redundancy regained.", 2011 "OK", 2012 "OK", 2013 0, 2014 {}, 2015 "None.", 2016 }}, 2017 MessageEntry{ 2018 "PowerUnitNonRedundantSufficient", 2019 { 2020 "Indicates that power unit is not in redundancy mode but still" 2021 "has sufficient power to support redundancy.", 2022 "Power Unit Nonredundant but has sufficient resource.", 2023 "Warning", 2024 "Warning", 2025 0, 2026 {}, 2027 "None.", 2028 }}, 2029 MessageEntry{"ResetButtonPressed", 2030 { 2031 "Indicates that the reset button was pressed.", 2032 "Reset Button Pressed.", 2033 "OK", 2034 "OK", 2035 0, 2036 {}, 2037 "None.", 2038 }}, 2039 MessageEntry{"SecurityBoot2ndFlashEnabled", 2040 { 2041 "Indicates that the BMC 2nd boot flash is enabled.", 2042 "BMC 2nd boot flash is enabled.", 2043 "Critical", 2044 "Critical", 2045 0, 2046 {}, 2047 "None.", 2048 }}, 2049 MessageEntry{"SecurityP2aBridgeEnabled", 2050 { 2051 "Indicates that the P2A bridge is enabled.", 2052 "P2A(PCIe to AHB) bridge is enabled.", 2053 "Critical", 2054 "Critical", 2055 0, 2056 {}, 2057 "None.", 2058 }}, 2059 MessageEntry{"SecurityUartPortDebugEnabled", 2060 { 2061 "Indicates that the uart port debug is enabled.", 2062 "Uart port debug is enabled.", 2063 "Critical", 2064 "Critical", 2065 0, 2066 {}, 2067 "None.", 2068 }}, 2069 MessageEntry{ 2070 "SecurityUserStrongHashAlgoRestored", 2071 { 2072 "Indicates that password computing hash algorithm changed.", 2073 "Password computing hash algorithm is changed to sha256/sha512.", 2074 "OK", 2075 "OK", 2076 0, 2077 {}, 2078 "None.", 2079 }}, 2080 2081 MessageEntry{"SecurityUserNonRootUidZeroAssigned", 2082 { 2083 "Indicates that non root user assigned with user ID zero.", 2084 "User ID Zero is assigned with non-root user.", 2085 "Critical", 2086 "Critical", 2087 0, 2088 {}, 2089 "None.", 2090 }}, 2091 MessageEntry{"SecurityUserNonRootUidZeroRemoved", 2092 { 2093 "Indicates that non root user ID is removed", 2094 "Non root user assigned with user ID zero is removed.", 2095 "OK", 2096 "OK", 2097 0, 2098 {}, 2099 "None.", 2100 }}, 2101 2102 MessageEntry{"SecurityUserRootEnabled", 2103 { 2104 "Indicates that system root user is enabled.", 2105 "User root is enabled.", 2106 "Critical", 2107 "Critical", 2108 0, 2109 {}, 2110 "None.", 2111 }}, 2112 MessageEntry{"SecurityUserRootDisabled", 2113 { 2114 "Indicates that system root user is disabled.", 2115 "User root is disabled.", 2116 "OK", 2117 "OK", 2118 0, 2119 {}, 2120 "None.", 2121 }}, 2122 2123 MessageEntry{"SecurityUserUnsupportedShellEnabled", 2124 { 2125 "Indicates that unsupported shell is enabled.", 2126 "Unsupported shell is enabled.", 2127 "Critical", 2128 "Critical", 2129 0, 2130 {}, 2131 "None.", 2132 }}, 2133 MessageEntry{"SecurityUserUnsupportedShellRemoved", 2134 { 2135 "Indicates that unsupported shell is removed.", 2136 "Unsupported shell is removed.", 2137 "OK", 2138 "OK", 2139 0, 2140 {}, 2141 "None.", 2142 }}, 2143 2144 MessageEntry{ 2145 "SecurityUserWeakHashAlgoEnabled", 2146 { 2147 "Indicates that weak password computing hash algorithm is enabled.", 2148 "Weak password computing hash algorithm is enabled.", 2149 "Critical", 2150 "Critical", 2151 0, 2152 {}, 2153 "None.", 2154 }}, 2155 MessageEntry{"SELEntryAdded", 2156 { 2157 "Indicates a SEL entry was added using the " 2158 "Add SEL Entry or Platform Event command.", 2159 "SEL Entry Added: %1", 2160 "OK", 2161 "OK", 2162 1, 2163 2164 { 2165 "string", 2166 }, 2167 "None.", 2168 }}, 2169 MessageEntry{"SensorThresholdCriticalHighGoingHigh", 2170 { 2171 "Indicates that a threshold sensor has crossed a " 2172 "critical high threshold going high.", 2173 "%1 sensor crossed a critical high threshold going " 2174 "high. Reading=%2 Threshold=%3.", 2175 "Critical", 2176 "Critical", 2177 3, 2178 {"string", "number", "number"}, 2179 "Check the sensor or subsystem for errors.", 2180 }}, 2181 MessageEntry{"SensorThresholdCriticalHighGoingLow", 2182 { 2183 "Indicates that a threshold sensor has crossed a " 2184 "critical high threshold going low.", 2185 "%1 sensor crossed a critical high threshold going low. " 2186 "Reading=%2 Threshold=%3.", 2187 "OK", 2188 "OK", 2189 3, 2190 {"string", "number", "number"}, 2191 "None.", 2192 }}, 2193 MessageEntry{"SensorThresholdCriticalLowGoingHigh", 2194 { 2195 "Indicates that a threshold sensor has crossed a " 2196 "critical low threshold going high.", 2197 "%1 sensor crossed a critical low threshold going high. " 2198 "Reading=%2 Threshold=%3.", 2199 "OK", 2200 "OK", 2201 3, 2202 {"string", "number", "number"}, 2203 "None.", 2204 }}, 2205 MessageEntry{"SensorThresholdCriticalLowGoingLow", 2206 { 2207 "Indicates that a threshold sensor has crossed a " 2208 "critical low threshold going low.", 2209 "%1 sensor crossed a critical low threshold going low. " 2210 "Reading=%2 Threshold=%3.", 2211 "Critical", 2212 "Critical", 2213 3, 2214 {"string", "number", "number"}, 2215 "Check the sensor or subsystem for errors.", 2216 }}, 2217 MessageEntry{"SensorThresholdWarningHighGoingHigh", 2218 { 2219 "Indicates that a threshold sensor has crossed a " 2220 "warning high threshold going high.", 2221 "%1 sensor crossed a warning high threshold going high. " 2222 "Reading=%2 Threshold=%3.", 2223 "Warning", 2224 "Warning", 2225 3, 2226 {"string", "number", "number"}, 2227 "Check the sensor or subsystem for errors.", 2228 }}, 2229 MessageEntry{"SensorThresholdWarningHighGoingLow", 2230 { 2231 "Indicates that a threshold sensor has crossed a " 2232 "warning high threshold going low.", 2233 "%1 sensor crossed a warning high threshold going low. " 2234 "Reading=%2 Threshold=%3.", 2235 "OK", 2236 "OK", 2237 3, 2238 {"string", "number", "number"}, 2239 "None.", 2240 }}, 2241 MessageEntry{"SensorThresholdWarningLowGoingHigh", 2242 { 2243 "Indicates that a threshold sensor has crossed a " 2244 "warning low threshold going high.", 2245 "%1 sensor crossed a warning low threshold going high. " 2246 "Reading=%2 Threshold=%3.", 2247 "OK", 2248 "OK", 2249 3, 2250 {"string", "number", "number"}, 2251 "None.", 2252 }}, 2253 MessageEntry{"SensorThresholdWarningLowGoingLow", 2254 { 2255 "Indicates that a threshold sensor has crossed a " 2256 "warning low threshold going low.", 2257 "%1 sensor crossed a warning low threshold going low. " 2258 "Reading=%2 Threshold=%3.", 2259 "Warning", 2260 "Warning", 2261 3, 2262 {"string", "number", "number"}, 2263 "Check the sensor or subsystem for errors.", 2264 }}, 2265 MessageEntry{"ServiceFailure", 2266 { 2267 "Indicates that a service has exited unsuccessfully.", 2268 "Service %1 has exited unsuccessfully.", 2269 "Warning", 2270 "Warning", 2271 1, 2272 {"string"}, 2273 "None.", 2274 }}, 2275 MessageEntry{"SparingRedundancyDegraded", 2276 { 2277 "Indicates the sparing redundancy state is degraded.", 2278 "Sparing redundancy state degraded. Socket=%1 " 2279 "Channel=%2 DIMM=%3 Domain=%4 Rank=%5.", 2280 "Warning", 2281 "Warning", 2282 5, 2283 2284 { 2285 "number", 2286 "string", 2287 "number", 2288 "string", 2289 "number", 2290 }, 2291 "None.", 2292 }}, 2293 MessageEntry{ 2294 "SparingRedundancyFull", 2295 { 2296 "Indicates the sparing redundancy state is fully redundant.", 2297 "Sparing redundancy state fully redundant. Socket=%1 " 2298 "Channel=%2 DIMM=%3 Domain=%4 Rank=%5.", 2299 "OK", 2300 "OK", 2301 5, 2302 2303 { 2304 "number", 2305 "string", 2306 "number", 2307 "string", 2308 "number", 2309 }, 2310 "None.", 2311 }}, 2312 MessageEntry{"SsbThermalTrip", 2313 { 2314 "Indicates that an SSB Thermal trip has been asserted.", 2315 "SSB Thermal trip.", 2316 "Critical", 2317 "Critical", 2318 0, 2319 {}, 2320 "None.", 2321 }}, 2322 MessageEntry{"SystemInterfaceDisabledProvisioned", 2323 { 2324 "Indicates that the system interface is in the disabled " 2325 "provisioned state. All commands are blocked to execute " 2326 "through the system interface.", 2327 "The system interface is in the disabled provisioned " 2328 "state.", 2329 "OK", 2330 "OK", 2331 0, 2332 {}, 2333 "None.", 2334 }}, 2335 MessageEntry{"SystemInterfaceUnprovisioned", 2336 { 2337 "Indicates that the system interface is in the " 2338 "unprovisioned state. All commands are permitted to " 2339 "execute through the system interface.", 2340 "The system interface is in the unprovisioned state.", 2341 "Critical", 2342 "Critical", 2343 0, 2344 {}, 2345 "None.", 2346 }}, 2347 MessageEntry{"SystemInterfaceWhitelistProvisioned", 2348 { 2349 "Indicates that the system interface is in the whitelist " 2350 "provisioned state. Only whitelisted commands " 2351 "are permitted to execute through the system interface.", 2352 "The system interface is in the whitelist provisioned " 2353 "state.", 2354 "Warning", 2355 "Warning", 2356 0, 2357 {}, 2358 "None.", 2359 }}, 2360 MessageEntry{"SystemPowerGoodFailed", 2361 { 2362 "Indicates that the system power good signal failed " 2363 "to assert within the specified time (VR failure).", 2364 "System power good failed to assert within %1 " 2365 "milliseconds (VR failure).", 2366 "Critical", 2367 "Critical", 2368 1, 2369 {"number"}, 2370 "None.", 2371 }}, 2372 MessageEntry{"SystemPowerLost", 2373 { 2374 "Indicates that power was lost while the " 2375 "system was powered on.", 2376 "System Power Lost.", 2377 "Critical", 2378 "Critical", 2379 0, 2380 {}, 2381 "None.", 2382 }}, 2383 MessageEntry{"SystemPowerOffFailed", 2384 { 2385 "Indicates that the system failed to power off.", 2386 "System Power-Off Failed.", 2387 "Critical", 2388 "Critical", 2389 0, 2390 {}, 2391 "None.", 2392 }}, 2393 MessageEntry{"SystemPowerOnFailed", 2394 { 2395 "Indicates that the system failed to power on.", 2396 "System Power-On Failed.", 2397 "Critical", 2398 "Critical", 2399 0, 2400 {}, 2401 "None.", 2402 }}, 2403 MessageEntry{ 2404 "VoltageRegulatorOverheated", 2405 { 2406 "Indicates that the specified voltage regulator overheated.", 2407 "%1 Voltage Regulator Overheated.", 2408 "Critical", 2409 "Critical", 2410 1, 2411 {"string"}, 2412 "None.", 2413 }}, 2414 2415 }; 2416 } // namespace redfish::message_registries::openbmc 2417