1 /* 2 // Copyright (c) 2019 Intel Corporation 3 // 4 // Licensed under the Apache License, Version 2.0 (the "License"); 5 // you may not use this file except in compliance with the License. 6 // You may obtain a copy of the License at 7 // 8 // http://www.apache.org/licenses/LICENSE-2.0 9 // 10 // Unless required by applicable law or agreed to in writing, software 11 // distributed under the License is distributed on an "AS IS" BASIS, 12 // WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. 13 // See the License for the specific language governing permissions and 14 // limitations under the License. 15 */ 16 #pragma once 17 18 #include "registries.hpp" 19 20 #include <array> 21 22 /* 23 Please read this before making edits to the structure below. 24 25 Messages in this registry are intended to be generally useful across 26 OpenBMC systems. To that end, there are a number of guidelines needed for 27 messages in this file to remain useful across systems. 28 29 1. Messages should not be specific to a piece or type of hardware. Generally 30 this involves not using terms like "CPU", "Drive", "Backplane", etc in the 31 message strings, unless that behavior is specific to that particular piece of 32 hardware. 33 Incorrect: MemoryOverheated 34 Correct: DeviceOverheated 35 Correct: MemoryECCError (ECC is specific to memory, therefore class specific 36 is acceptable) 37 38 2. Messages should not use any proprietary, copyright, or company-specific 39 terms. In general, messages should prefer the industry accepted term. 40 41 3. Message strings should be human readable, and read like a normal 42 sentence. This generally involves placing the substitution parameters in the 43 appropriate place in the string. 44 45 Incorrect: "An error occurred. Device: %1" 46 47 Correct: "An error occurred on device %1". 48 49 4. Message registry versioning semantics shall be obeyed. Adding new 50 messages require an increment to the subminor revision. Changes to existing 51 messages require an increment to the patch version. If the copyright year is 52 different than the current date, increment it when the version is changed. 53 54 5. If you are changing this in your own downstream company-specific fork, 55 please change the "id" field below away from "OpenBMC.0.X.X" to something of 56 the form of "CompanyName.0.X.X". This is to ensure that when a system is 57 found in industry that has modified this registry, it can be differentiated 58 from the OpenBMC project maintained registry. 59 60 6. Keep the below list alphabetized by message id. 61 */ 62 63 namespace redfish::registries::openbmc 64 { 65 const Header header = { 66 "Copyright 2022 OpenBMC. All rights reserved.", 67 "#MessageRegistry.v1_4_0.MessageRegistry", 68 "OpenBMC.0.4.0", 69 "OpenBMC Message Registry", 70 "en", 71 "This registry defines the base messages for OpenBMC.", 72 "OpenBMC", 73 "0.4.0", 74 "OpenBMC", 75 }; 76 constexpr std::array registry = { 77 MessageEntry{ 78 "ADDDCCorrectable", 79 { 80 "Indicates an ADDDC Correctable Error.", 81 "ADDDC Correctable Error.Socket=%1 Channel=%2 DIMM=%3 Rank=%4.", 82 "Warning", 83 4, 84 { 85 "number", 86 "string", 87 "number", 88 "number", 89 }, 90 "None.", 91 }}, 92 MessageEntry{ 93 "AtScaleDebugFeatureEnabledAtHardware", 94 { 95 "Indicates that At-Scale Debug enable is detected in hardware.", 96 "At-Scale Debug Feature is enabled in hardware.", 97 "Critical", 98 0, 99 {}, 100 "None.", 101 }}, 102 MessageEntry{ 103 "AtScaleDebugFeatureDisabledAtHardware", 104 { 105 "Indicates that At-Scale Debug disable is detected in hardware.", 106 "At-Scale Debug Feature is disabled in hardware.", 107 "OK", 108 0, 109 {}, 110 "None.", 111 }}, 112 MessageEntry{"AtScaleDebugFeatureEnabled", 113 { 114 "Indicates that At-Scale Debug service is started.", 115 "At-Scale Debug service is started.", 116 "Critical", 117 0, 118 {}, 119 "None.", 120 }}, 121 MessageEntry{"AtScaleDebugFeatureDisabled", 122 { 123 "Indicates that At-Scale Debug service is stopped.", 124 "At-Scale Debug service is stopped.", 125 "OK", 126 0, 127 {}, 128 "None.", 129 }}, 130 MessageEntry{"AtScaleDebugConnected", 131 { 132 "Indicates At-Scale Debug connection has been established", 133 "At-Scale Debug service is now connected %1", 134 "Critical", 135 1, 136 {"string"}, 137 "None.", 138 }}, 139 MessageEntry{"AtScaleDebugDisconnected", 140 { 141 "Indicates At-Scale Debug connection has ended", 142 "At-Scale Debug service is now disconnected", 143 "OK", 144 0, 145 {}, 146 "None.", 147 }}, 148 MessageEntry{"AtScaleDebugConnectionFailed", 149 { 150 "Indicates At-Scale Debug connection aborted/failed", 151 "At-Scale Debug connection aborted/failed", 152 "Critical", 153 0, 154 {}, 155 "None.", 156 }}, 157 MessageEntry{"AtScaleDebugSpecialUserEnabled", 158 { 159 "Indicates that special user is enabled.", 160 "At-Scale Debug special user is enabled", 161 "Critical", 162 0, 163 {}, 164 "None.", 165 }}, 166 MessageEntry{"AtScaleDebugSpecialUserDisabled", 167 { 168 "Indicates that special user is disabled.", 169 "At-Scale Debug special user is disabled", 170 "OK", 171 0, 172 {}, 173 "None.", 174 }}, 175 176 MessageEntry{"BIOSAttributesChanged", 177 { 178 "Indicates that a set of BIOS Attributes has changed.", 179 "Set of BIOS Attributes changed.", 180 "OK", 181 0, 182 {}, 183 "None.", 184 }}, 185 MessageEntry{ 186 "BIOSBoot", 187 { 188 "Indicates BIOS has transitioned control to the OS Loader.", 189 "BIOS System Boot.", 190 "OK", 191 0, 192 {}, 193 "None.", 194 }}, 195 MessageEntry{"BIOSFirmwarePanicReason", 196 { 197 "Indicates the reason for BIOS firmware panic.", 198 "BIOS firmware panic occurred due to %1.", 199 "Warning", 200 1, 201 { 202 "string", 203 }, 204 "None.", 205 }}, 206 MessageEntry{"BIOSFirmwareRecoveryReason", 207 { 208 "Indicates the reason for BIOS firmware recovery.", 209 "BIOS firmware recovery occurred due to %1.", 210 "Warning", 211 1, 212 { 213 "string", 214 }, 215 "None.", 216 }}, 217 MessageEntry{"BIOSFirmwareResiliencyError", 218 { 219 "Indicates BIOS firmware encountered resilience error.", 220 "BIOS firmware resiliency error. Error reason: %1.", 221 "Critical", 222 1, 223 { 224 "string", 225 }, 226 "None.", 227 }}, 228 MessageEntry{ 229 "BIOSPOSTCode", 230 { 231 "BIOS Power-On Self-Test Code received", 232 "Boot Count: %1; Time Stamp Offset: %2 seconds; POST Code: %3", 233 "OK", 234 3, 235 {"number", "number", "number"}, 236 "None.", 237 }}, 238 MessageEntry{"BIOSPOSTError", 239 { 240 "Indicates BIOS POST has encountered an error.", 241 "BIOS POST Error. Error Code=%1", 242 "Warning", 243 1, 244 {"number"}, 245 "None.", 246 }}, 247 MessageEntry{"BIOSRecoveryComplete", 248 { 249 "Indicates BIOS Recovery has completed.", 250 "BIOS Recovery Complete.", 251 "OK", 252 0, 253 {}, 254 "None.", 255 }}, 256 MessageEntry{"BIOSRecoveryStart", 257 { 258 "Indicates BIOS Recovery has started.", 259 "BIOS Recovery Start.", 260 "Warning", 261 0, 262 {}, 263 "None.", 264 }}, 265 MessageEntry{"BMCBootReason", 266 { 267 "Indicates the reason why BMC firmware booted.", 268 "BMC firmware version %1 booted due to %2.", 269 "OK", 270 2, 271 { 272 "string", 273 "string", 274 }, 275 "None.", 276 }}, 277 MessageEntry{"BMCFirmwarePanicReason", 278 { 279 "Indicates the reason for last BMC firmware panic.", 280 "BMC firmware panic occurred due to %1.", 281 "Warning", 282 1, 283 { 284 "string", 285 }, 286 "None.", 287 }}, 288 MessageEntry{"BMCFirmwareRecoveryReason", 289 { 290 "Indicates the reason for last BMC firmware recovery.", 291 "BMC firmware recovery occurred due to %1.", 292 "Warning", 293 1, 294 { 295 "string", 296 }, 297 "None.", 298 }}, 299 MessageEntry{"BMCFirmwareResiliencyError", 300 { 301 "Indicates BMC firmware encountered resilience error.", 302 "BMC firmware resiliency error. Error reason: %1.", 303 "Critical", 304 1, 305 { 306 "string", 307 }, 308 "None.", 309 }}, 310 MessageEntry{"BMCKernelPanic", 311 { 312 "Indicates that BMC kernel panic occurred.", 313 "BMC rebooted due to kernel panic.", 314 "OK", 315 0, 316 {}, 317 "None.", 318 }}, 319 MessageEntry{"ChassisIntrusionDetected", 320 { 321 "Indicates that a physical security event " 322 "of the chassis intrusion has occurred.", 323 "Chassis Intrusion Detected.", 324 "Warning", 325 0, 326 {}, 327 "None.", 328 }}, 329 MessageEntry{"ChassisIntrusionReset", 330 { 331 "Indicates that chassis intrusion status has recovered.", 332 "Chassis Intrusion Reset.", 333 "OK", 334 0, 335 {}, 336 "None.", 337 }}, 338 MessageEntry{ 339 "ComponentOverTemperature", 340 { 341 "Indicates that the specified component is over temperature.", 342 "%1 over temperature and being throttled.", 343 "Critical", 344 1, 345 {"string"}, 346 "None.", 347 }}, 348 MessageEntry{"CPLDFirmwarePanicReason", 349 { 350 "Indicates the reason for CPLD firmware panic.", 351 "CPLD firmware panic occurred due to %1.", 352 "Warning", 353 1, 354 { 355 "string", 356 }, 357 "None.", 358 }}, 359 MessageEntry{"CPLDFirmwareRecoveryReason", 360 { 361 "Indicates the reason for CPLD firmware recovery.", 362 "CPLD firmware recovery occurred due to %1.", 363 "Warning", 364 1, 365 { 366 "string", 367 }, 368 "None.", 369 }}, 370 MessageEntry{"CPLDFirmwareResiliencyError", 371 { 372 "Indicates CPLD firmware encountered resilience error.", 373 "CPLD firmware resiliency error. Error reason: %1.", 374 "Critical", 375 1, 376 { 377 "string", 378 }, 379 "None.", 380 }}, 381 MessageEntry{"CPUError", 382 { 383 "Indicates that a CPU Error occurred of " 384 "the specified type or cause.", 385 "CPU Error Occurred: %1.", 386 "Critical", 387 1, 388 {"string"}, 389 "None.", 390 }}, 391 MessageEntry{"CPUMismatch", 392 { 393 "Indicates that the specified CPU power/current " 394 "rating is incompatible with the board.", 395 "CPU %1 Mismatch.", 396 "Critical", 397 1, 398 {"number"}, 399 "Install the supported CPU.", 400 }}, 401 MessageEntry{"CPUThermalTrip", 402 { 403 "Indicates that the specified CPU thermal " 404 "trip has been asserted.", 405 "CPU %1 Thermal Trip.", 406 "Critical", 407 1, 408 {"number"}, 409 "None.", 410 }}, 411 MessageEntry{"DCPowerOff", 412 { 413 "Indicates that the system DC power is off.", 414 "Host system DC power is off", 415 "OK", 416 0, 417 {}, 418 "None.", 419 }}, 420 MessageEntry{"DCPowerOn", 421 { 422 "Indicates that the system DC power is on.", 423 "Host system DC power is on", 424 "OK", 425 0, 426 {}, 427 "None.", 428 }}, 429 MessageEntry{"DriveError", 430 { 431 "Indicates that a Drive Error occurred of " 432 "the specified type or cause.", 433 "Drive Error Occurred: %1.", 434 "Warning", 435 1, 436 {"string"}, 437 "None.", 438 }}, 439 MessageEntry{"EventLogCleared", 440 { 441 "Indicates that the event log has been cleared.", 442 "Event Log Cleared.", 443 "OK", 444 0, 445 {}, 446 "None.", 447 }}, 448 MessageEntry{"FanInserted", 449 { 450 "Indicates that a system fan has been inserted.", 451 "%1 inserted.", 452 "OK", 453 1, 454 {"string"}, 455 "None.", 456 }}, 457 MessageEntry{"FanRedundancyLost", 458 { 459 "Indicates that system fan redundancy has been lost.", 460 "Fan redundancy lost.", 461 "Warning", 462 0, 463 {}, 464 "None.", 465 }}, 466 MessageEntry{"FanRedundancyRegained", 467 { 468 "Indicates that system fan redundancy has been regained.", 469 "Fan redundancy regained.", 470 "OK", 471 0, 472 {}, 473 "None.", 474 }}, 475 MessageEntry{"FanRemoved", 476 { 477 "Indicates that a system fan has been removed.", 478 "%1 removed.", 479 "OK", 480 1, 481 {"string"}, 482 "None.", 483 }}, 484 MessageEntry{ 485 "FirmwareActivationCompleted", 486 { 487 "Indicates a firmware activation has completed successfully.", 488 "%1 firmware activation completed successfully.", 489 "OK", 490 1, 491 {"string"}, 492 "None.", 493 }}, 494 MessageEntry{"FirmwareActivationFailed", 495 { 496 "Indicates a firmware activation has failed.", 497 "%1 firmware activation failed: %2.", 498 "Warning", 499 2, 500 {"string", "string"}, 501 "None.", 502 }}, 503 MessageEntry{"FirmwareActivationStarted", 504 { 505 "Indicates a firmware activation has started.", 506 "%1 firmware activation started.", 507 "OK", 508 1, 509 {"string"}, 510 "None.", 511 }}, 512 MessageEntry{"FirmwareResiliencyError", 513 { 514 "Indicates firmware encountered resilience error.", 515 "Firmware resiliency error. Error reason: %1.", 516 "Critical", 517 1, 518 { 519 "string", 520 }, 521 "None.", 522 }}, 523 MessageEntry{"FirmwareUpdateCompleted", 524 { 525 "Indicates a firmware update has completed successfully.", 526 "%1 firmware update to version %2 completed " 527 "successfully.", 528 "OK", 529 2, 530 {"string", "string"}, 531 "None.", 532 }}, 533 MessageEntry{"FirmwareUpdateFailed", 534 { 535 "Indicates a firmware update has failed.", 536 "%1 firmware update to version %2 failed: %3.", 537 "Warning", 538 3, 539 {"string", "string", "string"}, 540 "None.", 541 }}, 542 MessageEntry{"FirmwareUpdateStaged", 543 { 544 "Indicates a firmware update has staged successfully.", 545 "%1 firmware update to version %2 staged successfully.", 546 "OK", 547 2, 548 {"string", "string"}, 549 "None.", 550 }}, 551 MessageEntry{"FirmwareUpdateStarted", 552 { 553 "Indicates a firmware update has started.", 554 "%1 firmware update to version %2 started.", 555 "OK", 556 2, 557 {"string", "string"}, 558 "None.", 559 }}, 560 MessageEntry{ 561 "GeneralFirmwareSecurityViolation", 562 { 563 "Indicates a general firmware security violation has occurred.", 564 "Firmware security violation: %1.", 565 "Critical", 566 1, 567 {"string"}, 568 "None.", 569 }}, 570 MessageEntry{"InvalidLoginAttempted", 571 { 572 "Indicates that a login was attempted on the specified " 573 "interface with an invalid username or password.", 574 "Invalid username or password attempted on %1.", 575 "Warning", 576 1, 577 {"string"}, 578 "None.", 579 }}, 580 MessageEntry{"InvalidUpload", 581 { 582 "Indicates that the uploaded file was invalid.", 583 "Invalid file uploaded to %1: %2.", 584 "Warning", 585 2, 586 {"string", "string"}, 587 "None.", 588 }}, 589 MessageEntry{ 590 "InventoryAdded", 591 { 592 "Indicates that an inventory item with the specified model, " 593 "type, and serial number was installed.", 594 "%1 %2 with serial number %3 was installed.", 595 "OK", 596 3, 597 598 { 599 "string", 600 "string", 601 "string", 602 }, 603 "None.", 604 }}, 605 MessageEntry{ 606 "InventoryRemoved", 607 { 608 "Indicates that an inventory item with the specified model, " 609 "type, and serial number was removed.", 610 "%1 %2 with serial number %3 was removed.", 611 "OK", 612 3, 613 614 { 615 "string", 616 "string", 617 "string", 618 }, 619 "None.", 620 }}, 621 MessageEntry{ 622 "IntelUPILinkWidthReducedToHalf", 623 { 624 "Indicates Intel UPI link width has reduced to half width.", 625 "Intel UPI link width reduced to half. Node=%1.", 626 "Warning", 627 1, 628 629 { 630 "number", 631 }, 632 "None.", 633 }}, 634 MessageEntry{ 635 "IntelUPILinkWidthReducedToQuarter", 636 { 637 "Indicates Intel UPI link width has reduced to quarter width.", 638 "Intel UPI link width reduced to quarter. Node=%1.", 639 "Warning", 640 1, 641 642 { 643 "number", 644 }, 645 "None.", 646 }}, 647 648 MessageEntry{"IPMIWatchdog", 649 { 650 "Indicates that there is a host watchdog event.", 651 "Host Watchdog Event: %1", 652 "OK", 653 1, 654 { 655 "string", 656 }, 657 "None.", 658 }}, 659 MessageEntry{"LanLost", 660 { 661 "Indicates that a physical security event " 662 "of the LAN leash has lost.", 663 "%1 LAN leash lost.", 664 "Warning", 665 1, 666 { 667 "string", 668 }, 669 "None.", 670 }}, 671 MessageEntry{"LanRegained", 672 { 673 "Indicates that LAN link status has reconnected.", 674 "%1 LAN leash regained.", 675 "OK", 676 1, 677 { 678 "string", 679 }, 680 "None.", 681 }}, 682 MessageEntry{"LegacyPCIPERR", 683 { 684 "Indicates a Legacy PCI PERR.", 685 "Legacy PCI PERR. Bus=%1 Device=%2 Function=%3.", 686 "Warning", 687 3, 688 689 { 690 "number", 691 "number", 692 "number", 693 }, 694 "None.", 695 }}, 696 MessageEntry{"LegacyPCISERR", 697 { 698 "Indicates a Legacy PCI SERR.", 699 "Legacy PCI SERR. Bus=%1 Device=%2 Function=%3.", 700 "Critical", 701 3, 702 703 { 704 "number", 705 "number", 706 "number", 707 }, 708 "None.", 709 }}, 710 MessageEntry{"ManufacturingModeEntered", 711 { 712 "Indicates that the BMC entered Factory, " 713 "or Manufacturing mode.", 714 "Entered Manufacturing Mode.", 715 "Critical", 716 0, 717 {}, 718 "None.", 719 }}, 720 MessageEntry{"ManufacturingModeExited", 721 { 722 "Indicates that the BMC exited Factory, " 723 "or Manufacturing mode.", 724 "Exited Manufacturing Mode.", 725 "OK", 726 0, 727 {}, 728 "None.", 729 }}, 730 MessageEntry{"MEAutoConfigFailed", 731 { 732 "Indicates that Intel ME power sensor " 733 "auto-configuration has failed.", 734 "Intel ME power sensor auto-configuration failed. Power " 735 "monitoring, limiting and HW protection features might " 736 "be unavailable. Failure reason: %1", 737 "Critical", 738 1, 739 {"string"}, 740 "Ensure that Intel ME configuration for power " 741 "sources is correct.", 742 }}, 743 MessageEntry{ 744 "MEAutoConfigSuccess", 745 { 746 "Indicates that Intel ME has performed successful " 747 "power sensor auto-configuration.", 748 "Intel ME power sensor auto-configuration succeeded. " 749 "Determined sources for domain readings are: DC Power: %1 ; " 750 "Chassis Power: %2 ; PSU Efficiency: %3 ; Unamanaged power: %4", 751 "OK", 752 4, 753 {"string", "string", "string", "string"}, 754 "None.", 755 }}, 756 MessageEntry{"MEBootGuardHealthEvent", 757 { 758 "Indicates that Intel ME has detected error during " 759 "operations of Intel Boot Guard", 760 "Intel ME has detected following issue with Intel Boot " 761 "Guard: %1", 762 "Critical", 763 1, 764 {"string"}, 765 "None.", 766 }}, 767 MessageEntry{"MECpuDebugCapabilityDisabled", 768 { 769 "Indicates that Intel ME has detected situation in " 770 "which CPU Debug Capability is disabled.", 771 "CPU Debug Capability disabled", 772 "Warning", 773 0, 774 {}, 775 "None.", 776 }}, 777 MessageEntry{"MEDirectFlashUpdateRequested", 778 { 779 "Indicates that BIOS has requested Direct Flash " 780 "Update (DFU) of Intel ME", 781 "Intel ME Firmware switched to recovery mode to perform " 782 "full update from BIOS.", 783 "OK", 784 0, 785 {}, 786 "This is transient state. Intel ME Firmware should " 787 "return to operational mode after successful image " 788 "update performed by the BIOS.", 789 }}, 790 MessageEntry{ 791 "MEExceptionDuringShutdown", 792 { 793 "Indicates that Intel ME could not successfully " 794 "perform emergency host shutdown.", 795 "Power Down command triggered by Intel Node Manager policy " 796 "failure action and Intel ME forced shutdown. BMC probably did " 797 "not respond correctly to Chassis Control.", 798 "Warning", 799 0, 800 {}, 801 "Verify the Intel Node Manager policy configuration.", 802 }}, 803 MessageEntry{ 804 "MEFactoryResetError", 805 { 806 "Indicates that Intel ME has ben restored to factory preset.", 807 "Intel ME has performed automatic reset to factory " 808 "presets due to following reason: %1", 809 "Critical", 810 1, 811 {"string"}, 812 "If error is persistent the Flash device must be replaced.", 813 }}, 814 MessageEntry{ 815 "MEFactoryRestore", 816 { 817 "Indicates that Intel ME has ben restored to factory preset.", 818 "Intel ME has performed automatic reset to factory " 819 "presets due to following reason: %1", 820 "OK", 821 1, 822 {"string"}, 823 "If error is persistent the Flash device must be replaced.", 824 }}, 825 MessageEntry{ 826 "MEFirmwareException", 827 { 828 "Indicates that Intel ME has encountered firmware " 829 "exception during execution.", 830 "Intel ME has encountered firmware exception. Error code = %1", 831 "Warning", 832 1, 833 {"string"}, 834 "Restore factory presets using Force ME Recovery IPMI " 835 "command or by doing AC power cycle with Recovery jumper " 836 "asserted. If this does not clear the issue, reflash the SPI " 837 "flash. If the issue persists, provide the content of error " 838 "code to Intel support team for interpretation. (Error codes " 839 "are not documented because they only provide clues that must " 840 "be interpreted individually..", 841 }}, 842 MessageEntry{"MEFirmwarePanicReason", 843 { 844 "Indicates the reason for ME firmware panic.", 845 "ME firmware panic occurred due to %1.", 846 "Warning", 847 1, 848 { 849 "string", 850 }, 851 "None.", 852 }}, 853 MessageEntry{"MEFirmwareRecoveryReason", 854 { 855 "Indicates the reason for ME firmware recovery.", 856 "ME firmware recovery occurred due to %1.", 857 "Warning", 858 1, 859 { 860 "string", 861 }, 862 "None.", 863 }}, 864 MessageEntry{"MEFirmwareResiliencyError", 865 { 866 "Indicates ME firmware encountered resilience error.", 867 "ME firmware resiliency error. Error reason: %1.", 868 "Critical", 869 1, 870 { 871 "string", 872 }, 873 "None.", 874 }}, 875 876 MessageEntry{"MEFlashEraseError", 877 { 878 "Indicates that Intel ME was unable to finish flash " 879 "erase procedure.", 880 "Intel ME has encountered an error during Flash erasure " 881 "procedure probably due to Flash part corruption.", 882 "Critical", 883 0, 884 {}, 885 "The Flash device must be replaced.", 886 }}, 887 MessageEntry{"MEFlashStateInformation", 888 { 889 "Indicates that Intel ME has encountered a problem " 890 "during IO to flash device.", 891 "Intel ME has encountered problem during IO to flash " 892 "device. Reason: %1", 893 "Critical", 894 1, 895 {"string"}, 896 "If flash wear-out protection occurred wait until it " 897 "expires. Otherwise - flash device must be replaced.", 898 }}, 899 MessageEntry{"MEFlashStateInformationWritingEnabled", 900 { 901 "Indicates that Intel ME has encountered a problem " 902 "during IO to flash device.", 903 "Intel ME has encountered problem during IO to flash " 904 "device. Reason: %1", 905 "OK", 906 1, 907 {"string"}, 908 "If flash wear-out protection occurred wait until it " 909 "expires. Otherwise - flash device must be replaced.", 910 }}, 911 MessageEntry{"MEFlashVerificationError", 912 { 913 "Indicates that Intel ME encountered invalid flash " 914 "descriptor region.", 915 "Intel ME has detected invalid flash descriptor region. " 916 "Following error is detected: %1", 917 "Critical", 918 1, 919 {"string"}, 920 "Flash Descriptor Region must be created correctly.", 921 }}, 922 MessageEntry{ 923 "MEFlashWearOutWarning", 924 { 925 "Indicates that Intel ME has reached certain " 926 "threshold of flash write operations.", 927 "Warning threshold for number of flash operations has been " 928 "exceeded. Current percentage of write operations capacity: %1", 929 "Warning", 930 1, 931 {"number"}, 932 "No immediate repair action needed.", 933 }}, 934 935 MessageEntry{ 936 "MEImageExecutionFailed", 937 { 938 "Indicates that Intel ME could not load primary FW image.", 939 "Intel ME Recovery Image or backup operational image " 940 "loaded because operational image is corrupted. This " 941 "may be either caused by Flash device corruption or " 942 "failed upgrade procedure.", 943 "Critical", 944 0, 945 {}, 946 "Either the Flash device must be replaced (if error is " 947 "persistent) or the upgrade procedure must be started again.", 948 }}, 949 950 MessageEntry{ 951 "MEInternalError", 952 { 953 "Indicates that Intel ME encountered " 954 "internal error leading to watchdog reset.", 955 "Error during Intel ME execution. Watchdog " 956 "timeout has expired.", 957 "Critical", 958 0, 959 {}, 960 "Firmware should automatically recover from error state. " 961 "If error is persistent then operational image shall be updated " 962 "or hardware board repair is needed.", 963 }}, 964 MessageEntry{"MEManufacturingError", 965 { 966 "Indicates that Intel ME is unable to start in " 967 "operational mode due to wrong configuration.", 968 "Wrong manufacturing configuration detected by Intel ME " 969 "Firmware. Unable to start operational mode. Reason: %1", 970 "Critical", 971 1, 972 {"string"}, 973 " If error is persistent the Flash device must be " 974 "replaced or FW configuration must be updated. Trace " 975 "logs might be gathered for detailed information.", 976 }}, 977 MessageEntry{"MEMctpInterfaceError", 978 { 979 "Indicates that Intel ME has encountered an error " 980 "in MCTP protocol.", 981 "Intel ME has detected MCTP interface failure and it is " 982 "not functional any more. It may indicate the situation " 983 "when MCTP was not configured by BIOS or a defect which " 984 "may need a Host reset to recover from. Details: %1", 985 "Critical", 986 1, 987 {"string"}, 988 "Recovery via CPU Host reset or platform reset. If error " 989 "is persistent, deep-dive platform-level debugging is " 990 "required.", 991 }}, 992 MessageEntry{"MemoryECCCorrectable", 993 { 994 "Indicates a Correctable Memory ECC error.", 995 "Memory ECC correctable error. Socket=%1 " 996 "Channel=%2 DIMM=%3 Rank=%4.", 997 "Warning", 998 4, 999 1000 { 1001 "number", 1002 "string", 1003 "number", 1004 "number", 1005 }, 1006 "None.", 1007 }}, 1008 MessageEntry{"MemoryECCUncorrectable", 1009 { 1010 "Indicates an Uncorrectable Memory ECC error.", 1011 "Memory ECC uncorrectable error. Socket=%1 Channel=%2 " 1012 "DIMM=%3 Rank=%4.", 1013 "Critical", 1014 4, 1015 1016 { 1017 "number", 1018 "string", 1019 "number", 1020 "number", 1021 }, 1022 "None.", 1023 }}, 1024 MessageEntry{"MemoryParityCommandAndAddress", 1025 { 1026 "Indicates a Command and Address parity error.", 1027 "Command and Address parity error. Socket=%1 Channel=%2 " 1028 "DIMM=%3 ChannelValid=%4 DIMMValid=%5.", 1029 "Critical", 1030 5, 1031 1032 { 1033 "number", 1034 "string", 1035 "number", 1036 "number", 1037 "number", 1038 }, 1039 "None.", 1040 }}, 1041 MessageEntry{"MemoryParityNotKnown", 1042 { 1043 "Indicates an unknown parity error.", 1044 "Memory parity error. Socket=%1 Channel=%2 " 1045 "DIMM=%3 ChannelValid=%4 DIMMValid=%5.", 1046 "Critical", 1047 5, 1048 1049 { 1050 "number", 1051 "string", 1052 "number", 1053 "number", 1054 "number", 1055 }, 1056 "None.", 1057 }}, 1058 MessageEntry{"MemoryRASConfigurationDisabled", 1059 { 1060 "Indicates Memory RAS Disabled Configuration Status.", 1061 "Memory RAS Configuration Disabled. Error=%1 Mode=%2.", 1062 "OK", 1063 2, 1064 { 1065 "string", 1066 "string", 1067 }, 1068 "None.", 1069 }}, 1070 MessageEntry{"MemoryRASConfigurationEnabled", 1071 { 1072 "Indicates Memory RAS Enabled Configuration Status.", 1073 "Memory RAS Configuration Enabled. Error=%1 Mode=%2.", 1074 "OK", 1075 2, 1076 { 1077 "string", 1078 "string", 1079 }, 1080 "None.", 1081 }}, 1082 MessageEntry{"MemoryRASModeDisabled", 1083 { 1084 "Indicates Memory RAS Disabled Mode Selection.", 1085 "Memory RAS Mode Select Disabled. Prior Mode=%1 " 1086 "Selected Mode=%2.", 1087 "OK", 1088 2, 1089 { 1090 "string", 1091 "string", 1092 }, 1093 "None.", 1094 }}, 1095 MessageEntry{"MemoryRASModeEnabled", 1096 { 1097 "Indicates Memory RAS Enabled Mode Selection.", 1098 "Memory RAS Mode Select Enabled. Prior Mode=%1 Selected " 1099 "Mode=%2.", 1100 "OK", 1101 2, 1102 { 1103 "string", 1104 "string", 1105 }, 1106 "None.", 1107 }}, 1108 MessageEntry{"MemoryThermTrip", 1109 { 1110 "Indicates that the system memory ThermTrip is asserted " 1111 "by the specified component.", 1112 "Memory ThermTrip asserted: %1.", 1113 "Critical", 1114 1, 1115 {"string"}, 1116 "None.", 1117 }}, 1118 MessageEntry{"MEMultiPchModeMisconfig", 1119 { 1120 "Indicates that Intel ME has encountered " 1121 "problems in initializing Multi-PCH mode.", 1122 "Intel ME error in Multi-PCH mode: %1", 1123 "Critical", 1124 1, 1125 {"string"}, 1126 "None.", 1127 }}, 1128 MessageEntry{ 1129 "MEPeciOverDmiError", 1130 { 1131 "Indicates that Intel ME is unable to communicate " 1132 "using PECI over DMI.", 1133 "Intel ME has detected PECI over DMI interface failure " 1134 "and it is not functional any more. It may indicate the " 1135 "situation when PECI over DMI was not configured by " 1136 "BIOS or a defect which may require a CPU Host reset to " 1137 "recover from. Details: %1", 1138 "Critical", 1139 1, 1140 {"string"}, 1141 "Recovery via CPU Host reset or platform reset. If error is " 1142 "persistent, deep-dive platform-level debugging is required.", 1143 }}, 1144 MessageEntry{ 1145 "MEPttHealthEvent", 1146 { 1147 "Indicates that Intel ME has encountered issue with Intel PTT", 1148 "Intel ME has detected following issue with Intel PTT: %1", 1149 "Warning", 1150 1, 1151 {"string"}, 1152 "None.", 1153 }}, 1154 MessageEntry{ 1155 "MERecoveryGpioForced", 1156 { 1157 "Indicates that Intel ME image is booted in " 1158 "recovery mode due to GPIO assertion.", 1159 "Intel ME Recovery Image loaded due to recovery MGPIO " 1160 "pin asserted. Pin number is configurable in factory " 1161 "presets, Default recovery pin is MGPIO1.", 1162 "OK", 1163 0, 1164 {}, 1165 "Deassert recovery GPIO and reset the Intel ME back to " 1166 "operational mode. If Recovery Jumper is in legacy behavior, " 1167 "a ME reset (eg. Cold Reset IPMI cmd) is needed to have ME " 1168 "back in operational mode.", 1169 }}, 1170 MessageEntry{"MERestrictedMode", 1171 { 1172 "Indicates events related to Intel ME restricted mode.", 1173 "Intel ME restricted mode information: %1", 1174 "Critical", 1175 1, 1176 {"string"}, 1177 "None.", 1178 }}, 1179 MessageEntry{ 1180 "MESmbusLinkFailure", 1181 { 1182 "Indicate that Intel ME encountered SMBus link error.", 1183 "Intel ME has detected SMBus link error. " 1184 "Sensor Bus: %1 , MUX Address: %2 ", 1185 "Critical", 1186 2, 1187 {"string", "string"}, 1188 "Devices connected to given SMLINK might cause communication " 1189 "corruption. See error code and refer to Intel ME External " 1190 "Interfaces Specification for details.", 1191 }}, 1192 MessageEntry{ 1193 "MEUmaError", 1194 { 1195 "Indicates that Intel ME has encountered UMA operation error.", 1196 "Intel ME has encountered UMA operation error. Details: %1", 1197 "Critical", 1198 1, 1199 {"string"}, 1200 "Platform reset when UMA not configured correctly, or when " 1201 "error occurred during normal operation on correctly " 1202 "configured UMA multiple times leading to Intel ME entering " 1203 "Recovery or restricted operational mode.", 1204 }}, 1205 MessageEntry{"MEUnsupportedFeature", 1206 { 1207 "Indicates that Intel ME is configuration with " 1208 "feature which is not supported on this platform.", 1209 "Feature not supported in current segment detected by " 1210 "Intel ME Firmware. Details: %1", 1211 "Critical", 1212 1, 1213 {"string"}, 1214 "Proper FW configuration must be updated or use the " 1215 "Flash device with proper FW configuration", 1216 }}, 1217 MessageEntry{"MirroringRedundancyDegraded", 1218 { 1219 "Indicates the mirroring redundancy state is degraded.", 1220 "Mirroring redundancy state degraded. Socket=%1 " 1221 "Channel=%2 DIMM=%3 Pair=%4 Rank=%5.", 1222 "Warning", 1223 5, 1224 1225 { 1226 "number", 1227 "string", 1228 "number", 1229 "number", 1230 "number", 1231 }, 1232 "None.", 1233 }}, 1234 MessageEntry{ 1235 "MirroringRedundancyFull", 1236 { 1237 "Indicates the mirroring redundancy state is fully redundant.", 1238 "Mirroring redundancy state fully redundant. Socket=%1 " 1239 "Channel=%2 DIMM=%3 Pair=%4 Rank=%5.", 1240 "OK", 1241 5, 1242 1243 { 1244 "number", 1245 "string", 1246 "number", 1247 "number", 1248 "number", 1249 }, 1250 "None.", 1251 }}, 1252 MessageEntry{"NMIButtonPressed", 1253 { 1254 "Indicates that the NMI button was pressed.", 1255 "NMI Button Pressed.", 1256 "Critical", 1257 0, 1258 {}, 1259 "None.", 1260 }}, 1261 MessageEntry{"NMIDiagnosticInterrupt", 1262 { 1263 "Indicates that an NMI Diagnostic " 1264 "Interrupt has been generated.", 1265 "NMI Diagnostic Interrupt.", 1266 "Critical", 1267 0, 1268 {}, 1269 "None.", 1270 }}, 1271 MessageEntry{"PCIeCorrectableAdvisoryNonFatal", 1272 { 1273 "Indicates a PCIe Correctable Advisory Non-fatal Error.", 1274 "PCIe Correctable Advisory Non-fatal Error. Bus=%1 " 1275 "Device=%2 Function=%3.", 1276 "Warning", 1277 3, 1278 1279 { 1280 "number", 1281 "number", 1282 "number", 1283 }, 1284 "None.", 1285 }}, 1286 MessageEntry{"PCIeCorrectableBadDLLP", 1287 { 1288 "Indicates a PCIe Correctable Bad DLLP Error.", 1289 1290 "PCIe Correctable Bad DLLP. Bus=%1 Device=%2 Function=%3.", 1291 "Warning", 1292 3, 1293 1294 { 1295 "number", 1296 "number", 1297 "number", 1298 }, 1299 "None.", 1300 }}, 1301 MessageEntry{"PCIeCorrectableBadTLP", 1302 { 1303 "Indicates a PCIe Correctable Bad TLP Error.", 1304 1305 "PCIe Correctable Bad TLP. Bus=%1 Device=%2 Function=%3.", 1306 "Warning", 1307 3, 1308 1309 { 1310 "number", 1311 "number", 1312 "number", 1313 }, 1314 "None.", 1315 }}, 1316 MessageEntry{"PCIeCorrectableHeaderLogOverflow", 1317 { 1318 "Indicates a PCIe Correctable Header Log Overflow Error.", 1319 "PCIe Correctable Header Log Overflow. Bus=%1 Device=%2 " 1320 "Function=%3.", 1321 "Warning", 1322 3, 1323 1324 { 1325 "number", 1326 "number", 1327 "number", 1328 }, 1329 "None.", 1330 }}, 1331 MessageEntry{"PCIeCorrectableInternal", 1332 { 1333 "Indicates a PCIe Correctable Internal Error.", 1334 "PCIe Correctable Internal Error. Bus=%1 Device=%2 " 1335 "Function=%3.", 1336 "Warning", 1337 3, 1338 1339 { 1340 "number", 1341 "number", 1342 "number", 1343 }, 1344 "None.", 1345 }}, 1346 MessageEntry{"PCIeCorrectableLinkBWChanged", 1347 { 1348 "Indicates a PCIe Correctable Link BW Changed Error.", 1349 "PCIe Correctable Link BW Changed. Bus=%1 " 1350 "Device=%2 Function=%3.", 1351 "Warning", 1352 3, 1353 1354 { 1355 "number", 1356 "number", 1357 "number", 1358 }, 1359 "None.", 1360 }}, 1361 MessageEntry{"PCIeCorrectableReceiverError", 1362 { 1363 "Indicates a PCIe Correctable Receiver Error.", 1364 "PCIe Correctable Receiver Error. Bus=%1 Device=%2 " 1365 "Function=%3.", 1366 "Warning", 1367 3, 1368 1369 { 1370 "number", 1371 "number", 1372 "number", 1373 }, 1374 "None.", 1375 }}, 1376 MessageEntry{"PCIeCorrectableReplayNumRollover", 1377 { 1378 "Indicates a PCIe Correctable Replay Num Rollover.", 1379 "PCIe Correctable Replay Num Rollover. Bus=%1 Device=%2 " 1380 "Function=%3.", 1381 "Warning", 1382 3, 1383 1384 { 1385 "number", 1386 "number", 1387 "number", 1388 }, 1389 "None.", 1390 }}, 1391 MessageEntry{"PCIeCorrectableReplayTimerTimeout", 1392 { 1393 "Indicates a PCIe Correctable Replay Timer Timeout.", 1394 "PCIe Correctable Replay Timer Timeout. Bus=%1 " 1395 "Device=%2 Function=%3.", 1396 "Warning", 1397 3, 1398 1399 { 1400 "number", 1401 "number", 1402 "number", 1403 }, 1404 "None.", 1405 }}, 1406 MessageEntry{"PCIeCorrectableUnspecifiedAERError", 1407 { 1408 "Indicates a PCIe Correctable Unspecified AER Error.", 1409 "PCIe Correctable Unspecified AER Error. " 1410 "Bus=%1 Device=%2 Function=%3.", 1411 "Warning", 1412 3, 1413 1414 { 1415 "number", 1416 "number", 1417 "number", 1418 }, 1419 "None.", 1420 }}, 1421 MessageEntry{"PCIeFatalACSViolation", 1422 { 1423 "Indicates a PCIe ACS Violation Error.", 1424 1425 "PCIe Fatal ACS Violation. Bus=%1 Device=%2 Function=%3.", 1426 "Critical", 1427 3, 1428 1429 { 1430 "number", 1431 "number", 1432 "number", 1433 }, 1434 "None.", 1435 }}, 1436 MessageEntry{"PCIeFatalAtomicEgressBlocked", 1437 { 1438 "Indicates a PCIe Atomic Egress Blocked Error.", 1439 "PCIe Fatal Atomic Egress Blocked. Bus=%1 Device=%2 " 1440 "Function=%3.", 1441 "Critical", 1442 3, 1443 1444 { 1445 "number", 1446 "number", 1447 "number", 1448 }, 1449 "None.", 1450 }}, 1451 MessageEntry{ 1452 "PCIeFatalCompleterAbort", 1453 { 1454 "Indicates a PCIe Completer Abort Error.", 1455 1456 "PCIe Fatal Completer Abort. Bus=%1 Device=%2 Function=%3.", 1457 "Critical", 1458 3, 1459 1460 { 1461 "number", 1462 "number", 1463 "number", 1464 }, 1465 "None.", 1466 }}, 1467 MessageEntry{ 1468 "PCIeFatalCompletionTimeout", 1469 { 1470 "Indicates a PCIe Completion Timeout Error.", 1471 1472 "PCIe Fatal Completion Timeout. Bus=%1 Device=%2 Function=%3.", 1473 "Critical", 1474 3, 1475 1476 { 1477 "number", 1478 "number", 1479 "number", 1480 }, 1481 "None.", 1482 }}, 1483 MessageEntry{ 1484 "PCIeFatalDataLinkLayerProtocol", 1485 { 1486 "Indicates a PCIe Data Link Layer Protocol Error.", 1487 1488 "PCIe Fatal Data Link Layer Protocol Error. Bus=%1 Device=%2 " 1489 "Function=%3.", 1490 "Critical", 1491 3, 1492 1493 { 1494 "number", 1495 "number", 1496 "number", 1497 }, 1498 "None.", 1499 }}, 1500 MessageEntry{"PCIeFatalECRCError", 1501 { 1502 "Indicates a PCIe ECRC Error.", 1503 "PCIe Fatal ECRC Error. Bus=%1 Device=%2 Function=%3.", 1504 "Critical", 1505 3, 1506 1507 { 1508 "number", 1509 "number", 1510 "number", 1511 }, 1512 "None.", 1513 }}, 1514 MessageEntry{"PCIeFatalFlowControlProtocol", 1515 { 1516 "Indicates a PCIe Flow Control Protocol Error.", 1517 1518 "PCIe Fatal Flow Control Protocol Error. Bus=%1 Device=%2 " 1519 "Function=%3.", 1520 "Critical", 1521 3, 1522 1523 { 1524 "number", 1525 "number", 1526 "number", 1527 }, 1528 "None.", 1529 }}, 1530 MessageEntry{ 1531 "PCIeFatalMalformedTLP", 1532 { 1533 "Indicates a PCIe Malformed TLP Error.", 1534 1535 "PCIe Fatal Malformed TLP Error. Bus=%1 Device=%2 Function=%3.", 1536 "Critical", 1537 3, 1538 1539 { 1540 "number", 1541 "number", 1542 "number", 1543 }, 1544 "None.", 1545 }}, 1546 MessageEntry{"PCIeFatalMCBlockedTLP", 1547 { 1548 "Indicates a PCIe MC Blocked TLP Error.", 1549 "PCIe Fatal MC Blocked TLP Error. Bus=%1 " 1550 "Device=%2 Function=%3.", 1551 "Critical", 1552 3, 1553 1554 { 1555 "number", 1556 "number", 1557 "number", 1558 }, 1559 "None.", 1560 }}, 1561 MessageEntry{ 1562 "PCIeFatalPoisonedTLP", 1563 { 1564 "Indicates a PCIe Poisoned TLP Error.", 1565 1566 "PCIe Fatal Poisoned TLP Error. Bus=%1 Device=%2 Function=%3.", 1567 "Critical", 1568 3, 1569 1570 { 1571 "number", 1572 "number", 1573 "number", 1574 }, 1575 "None.", 1576 }}, 1577 MessageEntry{"PCIeFatalReceiverBufferOverflow", 1578 { 1579 "Indicates a PCIe Receiver Buffer Overflow Error.", 1580 "PCIe Fatal Receiver Buffer Overflow. Bus=%1 Device=%2 " 1581 "Function=%3.", 1582 "Critical", 1583 3, 1584 1585 { 1586 "number", 1587 "number", 1588 "number", 1589 }, 1590 "None.", 1591 }}, 1592 MessageEntry{ 1593 "PCIeFatalReceivedErrNonFatalMessage", 1594 { 1595 "Indicates a PCIe Received ERR_NONFATAL Message Error.", 1596 1597 "PCIe Fatal Received ERR_NONFATAL Message. Bus=%1 Device=%2 " 1598 "Function=%3.", 1599 "Critical", 1600 3, 1601 1602 { 1603 "number", 1604 "number", 1605 "number", 1606 }, 1607 "None.", 1608 }}, 1609 MessageEntry{"PCIeFatalReceivedFatalMessageFromDownstream", 1610 { 1611 "Indicates a PCIe Received Fatal Message " 1612 "From Downstream Error.", 1613 1614 "PCIe Fatal Received Fatal Message From Downstream. " 1615 "Bus=%1 Device=%2 Function=%3.", 1616 "Critical", 1617 3, 1618 1619 { 1620 "number", 1621 "number", 1622 "number", 1623 }, 1624 "None.", 1625 }}, 1626 MessageEntry{"PCIeFatalSurpriseLinkDown", 1627 { 1628 "Indicates a PCIe Surprise Link Down Error.", 1629 "PCIe Fatal Surprise Link Down Error. Bus=%1 Device=%2 " 1630 "Function=%3.", 1631 "Critical", 1632 3, 1633 1634 { 1635 "number", 1636 "number", 1637 "number", 1638 }, 1639 "None.", 1640 }}, 1641 MessageEntry{"PCIeFatalTLPPrefixBlocked", 1642 { 1643 "Indicates a PCIe TLP Prefix Blocked Error.", 1644 "PCIe Fatal TLP Prefix Blocked Error. Bus=%1 Device=%2 " 1645 "Function=%3.", 1646 "Critical", 1647 3, 1648 1649 { 1650 "number", 1651 "number", 1652 "number", 1653 }, 1654 "None.", 1655 }}, 1656 MessageEntry{ 1657 "PCIeFatalUncorrectableInternal", 1658 { 1659 "Indicates a PCIe Uncorrectable Internal Error.", 1660 1661 "PCIe Fatal Uncorrectable Internal Error. Bus=%1 Device=%2 " 1662 "Function=%3.", 1663 "Critical", 1664 3, 1665 1666 { 1667 "number", 1668 "number", 1669 "number", 1670 }, 1671 "None.", 1672 }}, 1673 MessageEntry{"PCIeFatalUnexpectedCompletion", 1674 { 1675 "Indicates a PCIe Unexpected Completion Error.", 1676 "PCIe Fatal Unexpected Completion. Bus=%1 Device=%2 " 1677 "Function=%3.", 1678 "Critical", 1679 3, 1680 1681 { 1682 "number", 1683 "number", 1684 "number", 1685 }, 1686 "None.", 1687 }}, 1688 MessageEntry{"PCIeFatalUnspecifiedNonAERFatalError", 1689 { 1690 "Indicates a PCIe Unspecified Non-AER Fatal Error.", 1691 "PCIe Fatal Unspecified Non-AER Fatal Error. Bus=%1 " 1692 "Device=%2 Function=%3.", 1693 "Critical", 1694 3, 1695 1696 { 1697 "number", 1698 "number", 1699 "number", 1700 }, 1701 "None.", 1702 }}, 1703 MessageEntry{ 1704 "PCIeFatalUnsupportedRequest", 1705 { 1706 "Indicates a PCIe Unsupported Request Error.", 1707 1708 "PCIe Fatal Unsupported Request. Bus=%1 Device=%2 Function=%3.", 1709 "Critical", 1710 3, 1711 1712 { 1713 "number", 1714 "number", 1715 "number", 1716 }, 1717 "None.", 1718 }}, 1719 MessageEntry{"PowerButtonPressed", 1720 { 1721 "Indicates that the power button was pressed.", 1722 "Power Button Pressed.", 1723 "OK", 1724 0, 1725 {}, 1726 "None.", 1727 }}, 1728 MessageEntry{"PowerRestorePolicyApplied", 1729 { 1730 "Indicates that power was restored and the " 1731 "BMC has applied the restore policy.", 1732 "Power restore policy applied.", 1733 "OK", 1734 0, 1735 {}, 1736 "None.", 1737 }}, 1738 MessageEntry{"PowerSupplyConfigurationError", 1739 { 1740 "Indicates an error in power supply configuration.", 1741 "Power supply %1 configuration error.", 1742 "Warning", 1743 1, 1744 {"string"}, 1745 "None.", 1746 }}, 1747 MessageEntry{ 1748 "PowerSupplyConfigurationErrorRecovered", 1749 { 1750 "Indicates that power supply configuration error recovered " 1751 "from a failure.", 1752 "Power supply %1 configuration error recovered.", 1753 "OK", 1754 1, 1755 {"string"}, 1756 "None.", 1757 }}, 1758 MessageEntry{ 1759 "PowerSupplyFanFailed", 1760 { 1761 "Indicates that the specified power supply fan has failed.", 1762 "Power supply %1 fan %2 failed.", 1763 "Warning", 1764 2, 1765 {"string", "string"}, 1766 "None.", 1767 }}, 1768 MessageEntry{ 1769 "PowerSupplyFanRecovered", 1770 { 1771 "Indicates that the power supply fan recovered from a failure.", 1772 "Power supply %1 fan %2 recovered.", 1773 "OK", 1774 2, 1775 {"string", "string"}, 1776 "None.", 1777 }}, 1778 MessageEntry{"PowerSupplyFailed", 1779 { 1780 "Indicates that a power supply has failed.", 1781 "Power supply %1 failed.", 1782 "Warning", 1783 1, 1784 {"string"}, 1785 "None.", 1786 }}, 1787 MessageEntry{"PowerSupplyFailurePredicted", 1788 { 1789 "Indicates that a power supply is predicted to fail.", 1790 "Power supply %1 failure predicted.", 1791 "Warning", 1792 1, 1793 {"string"}, 1794 "None.", 1795 }}, 1796 MessageEntry{"PowerSupplyInserted", 1797 { 1798 "Indicates that a power supply has been inserted.", 1799 "Power supply %1 inserted.", 1800 "OK", 1801 1, 1802 {"string"}, 1803 "None.", 1804 }}, 1805 MessageEntry{"PowerSupplyPowerGoodFailed", 1806 { 1807 "Indicates that the power supply power good signal " 1808 "failed to assert within the specified time.", 1809 "Power supply power good failed to assert within %1 " 1810 "milliseconds.", 1811 "Critical", 1812 1, 1813 {"number"}, 1814 "None.", 1815 }}, 1816 MessageEntry{"PowerSupplyPowerLost", 1817 { 1818 "Indicates that a power supply has lost input power.", 1819 "Power supply %1 power lost.", 1820 "Warning", 1821 1, 1822 {"string"}, 1823 "None.", 1824 }}, 1825 MessageEntry{"PowerSupplyPowerRestored", 1826 { 1827 "Indicates that a power supply input power was restored.", 1828 "Power supply %1 power restored.", 1829 "OK", 1830 1, 1831 {"string"}, 1832 "None.", 1833 }}, 1834 MessageEntry{"PowerSupplyPredictedFailureRecovered", 1835 { 1836 "Indicates that a power supply recovered " 1837 "from a predicted failure.", 1838 "Power supply %1 predicted failure recovered.", 1839 "OK", 1840 1, 1841 {"string"}, 1842 "None.", 1843 }}, 1844 MessageEntry{"PowerSupplyRecovered", 1845 { 1846 "Indicates that a power supply recovered from a failure.", 1847 "Power supply %1 recovered.", 1848 "OK", 1849 1, 1850 {"string"}, 1851 "None.", 1852 }}, 1853 MessageEntry{"PowerSupplyRemoved", 1854 { 1855 "Indicates that a power supply has been removed.", 1856 "Power supply %1 removed.", 1857 "Warning", 1858 1, 1859 {"string"}, 1860 "None.", 1861 }}, 1862 MessageEntry{"PowerUnitDegradedFromNonRedundant", 1863 { 1864 "Indicates that power unit is come back to redundant from" 1865 "nonredundant but is still not in full redundancy mode.", 1866 "Power Unit degraded from nonredundant.", 1867 "Warning", 1868 0, 1869 {}, 1870 "None.", 1871 }}, 1872 MessageEntry{"PowerUnitDegradedFromRedundant", 1873 { 1874 "Indicates that power unit is degarded from full " 1875 "redundancy mode.", 1876 "Power Unit degraded from redundant.", 1877 "Warning", 1878 0, 1879 {}, 1880 "None.", 1881 }}, 1882 MessageEntry{"PowerUnitRedundancyDegraded", 1883 { 1884 "Indicates that power unit redundancy has been degraded.", 1885 "Power Unit Redundancy degraded.", 1886 "Warning", 1887 0, 1888 {}, 1889 "None.", 1890 }}, 1891 MessageEntry{ 1892 "PowerUnitNonRedundantFromInsufficient", 1893 { 1894 "Indicates that power unit is not in redundancy mode and get" 1895 "sufficient power to support redundancy from insufficient" 1896 "power.", 1897 1898 "Power Unit NonRedundant from insufficient to sufficient.", 1899 "Warning", 1900 0, 1901 {}, 1902 "None.", 1903 }}, 1904 MessageEntry{"PowerUnitNonRedundantInsufficient", 1905 { 1906 "Indicates that power unit do not have sufficient " 1907 "power to support redundancy.", 1908 "Power Unit NonRedundant and has insufficient resource.", 1909 "Critical", 1910 0, 1911 {}, 1912 "None.", 1913 }}, 1914 MessageEntry{"PowerUnitRedundancyLost", 1915 { 1916 "Indicates that power unit redundancy has been lost.", 1917 "Power Unit Redundancy lost.", 1918 "Warning", 1919 0, 1920 {}, 1921 "None.", 1922 }}, 1923 MessageEntry{ 1924 "PowerUnitRedundancyRegained", 1925 { 1926 "Indicates that power unit full redundancy has been regained.", 1927 "Power Unit Redundancy regained.", 1928 "OK", 1929 0, 1930 {}, 1931 "None.", 1932 }}, 1933 MessageEntry{ 1934 "PowerUnitNonRedundantSufficient", 1935 { 1936 "Indicates that power unit is not in redundancy mode but still" 1937 "has sufficient power to support redundancy.", 1938 "Power Unit Nonredundant but has sufficient resource.", 1939 "Warning", 1940 0, 1941 {}, 1942 "None.", 1943 }}, 1944 MessageEntry{"ResetButtonPressed", 1945 { 1946 "Indicates that the reset button was pressed.", 1947 "Reset Button Pressed.", 1948 "OK", 1949 0, 1950 {}, 1951 "None.", 1952 }}, 1953 MessageEntry{"SecurityBoot2ndFlashEnabled", 1954 { 1955 "Indicates that the BMC 2nd boot flash is enabled.", 1956 "BMC 2nd boot flash is enabled.", 1957 "Critical", 1958 0, 1959 {}, 1960 "None.", 1961 }}, 1962 MessageEntry{"SecurityP2aBridgeEnabled", 1963 { 1964 "Indicates that the P2A bridge is enabled.", 1965 "P2A(PCIe to AHB) bridge is enabled.", 1966 "Critical", 1967 0, 1968 {}, 1969 "None.", 1970 }}, 1971 MessageEntry{"SecurityUartPortDebugEnabled", 1972 { 1973 "Indicates that the uart port debug is enabled.", 1974 "Uart port debug is enabled.", 1975 "Critical", 1976 0, 1977 {}, 1978 "None.", 1979 }}, 1980 MessageEntry{ 1981 "SecurityUserStrongHashAlgoRestored", 1982 { 1983 "Indicates that password computing hash algorithm changed.", 1984 "Password computing hash algorithm is changed to sha256/sha512.", 1985 "OK", 1986 0, 1987 {}, 1988 "None.", 1989 }}, 1990 1991 MessageEntry{"SecurityUserNonRootUidZeroAssigned", 1992 { 1993 "Indicates that non root user assigned with user ID zero.", 1994 "User ID Zero is assigned with non-root user.", 1995 "Critical", 1996 0, 1997 {}, 1998 "None.", 1999 }}, 2000 MessageEntry{"SecurityUserNonRootUidZeroRemoved", 2001 { 2002 "Indicates that non root user ID is removed", 2003 "Non root user assigned with user ID zero is removed.", 2004 "OK", 2005 0, 2006 {}, 2007 "None.", 2008 }}, 2009 2010 MessageEntry{"SecurityUserRootEnabled", 2011 { 2012 "Indicates that system root user is enabled.", 2013 "User root is enabled.", 2014 "Critical", 2015 0, 2016 {}, 2017 "None.", 2018 }}, 2019 MessageEntry{"SecurityUserRootDisabled", 2020 { 2021 "Indicates that system root user is disabled.", 2022 "User root is disabled.", 2023 "OK", 2024 0, 2025 {}, 2026 "None.", 2027 }}, 2028 2029 MessageEntry{"SecurityUserUnsupportedShellEnabled", 2030 { 2031 "Indicates that unsupported shell is enabled.", 2032 "Unsupported shell is enabled.", 2033 "Critical", 2034 0, 2035 {}, 2036 "None.", 2037 }}, 2038 MessageEntry{"SecurityUserUnsupportedShellRemoved", 2039 { 2040 "Indicates that unsupported shell is removed.", 2041 "Unsupported shell is removed.", 2042 "OK", 2043 0, 2044 {}, 2045 "None.", 2046 }}, 2047 2048 MessageEntry{ 2049 "SecurityUserWeakHashAlgoEnabled", 2050 { 2051 "Indicates that weak password computing hash algorithm is enabled.", 2052 "Weak password computing hash algorithm is enabled.", 2053 "Critical", 2054 0, 2055 {}, 2056 "None.", 2057 }}, 2058 MessageEntry{"SELEntryAdded", 2059 { 2060 "Indicates a SEL entry was added using the " 2061 "Add SEL Entry or Platform Event command.", 2062 "SEL Entry Added: %1", 2063 "OK", 2064 1, 2065 { 2066 "string", 2067 }, 2068 "None.", 2069 }}, 2070 MessageEntry{"SensorThresholdCriticalHighGoingHigh", 2071 { 2072 "Indicates that a threshold sensor has crossed a " 2073 "critical high threshold going high.", 2074 "%1 sensor crossed a critical high threshold going " 2075 "high. Reading=%2 Threshold=%3.", 2076 "Critical", 2077 3, 2078 {"string", "number", "number"}, 2079 "Check the sensor or subsystem for errors.", 2080 }}, 2081 MessageEntry{"SensorThresholdCriticalHighGoingLow", 2082 { 2083 "Indicates that a threshold sensor has crossed a " 2084 "critical high threshold going low.", 2085 "%1 sensor crossed a critical high threshold going low. " 2086 "Reading=%2 Threshold=%3.", 2087 "OK", 2088 3, 2089 {"string", "number", "number"}, 2090 "None.", 2091 }}, 2092 MessageEntry{"SensorThresholdCriticalLowGoingHigh", 2093 { 2094 "Indicates that a threshold sensor has crossed a " 2095 "critical low threshold going high.", 2096 "%1 sensor crossed a critical low threshold going high. " 2097 "Reading=%2 Threshold=%3.", 2098 "OK", 2099 3, 2100 {"string", "number", "number"}, 2101 "None.", 2102 }}, 2103 MessageEntry{"SensorThresholdCriticalLowGoingLow", 2104 { 2105 "Indicates that a threshold sensor has crossed a " 2106 "critical low threshold going low.", 2107 "%1 sensor crossed a critical low threshold going low. " 2108 "Reading=%2 Threshold=%3.", 2109 "Critical", 2110 3, 2111 {"string", "number", "number"}, 2112 "Check the sensor or subsystem for errors.", 2113 }}, 2114 MessageEntry{"SensorThresholdWarningHighGoingHigh", 2115 { 2116 "Indicates that a threshold sensor has crossed a " 2117 "warning high threshold going high.", 2118 "%1 sensor crossed a warning high threshold going high. " 2119 "Reading=%2 Threshold=%3.", 2120 "Warning", 2121 3, 2122 {"string", "number", "number"}, 2123 "Check the sensor or subsystem for errors.", 2124 }}, 2125 MessageEntry{"SensorThresholdWarningHighGoingLow", 2126 { 2127 "Indicates that a threshold sensor has crossed a " 2128 "warning high threshold going low.", 2129 "%1 sensor crossed a warning high threshold going low. " 2130 "Reading=%2 Threshold=%3.", 2131 "OK", 2132 3, 2133 {"string", "number", "number"}, 2134 "None.", 2135 }}, 2136 MessageEntry{"SensorThresholdWarningLowGoingHigh", 2137 { 2138 "Indicates that a threshold sensor has crossed a " 2139 "warning low threshold going high.", 2140 "%1 sensor crossed a warning low threshold going high. " 2141 "Reading=%2 Threshold=%3.", 2142 "OK", 2143 3, 2144 {"string", "number", "number"}, 2145 "None.", 2146 }}, 2147 MessageEntry{"SensorThresholdWarningLowGoingLow", 2148 { 2149 "Indicates that a threshold sensor has crossed a " 2150 "warning low threshold going low.", 2151 "%1 sensor crossed a warning low threshold going low. " 2152 "Reading=%2 Threshold=%3.", 2153 "Warning", 2154 3, 2155 {"string", "number", "number"}, 2156 "Check the sensor or subsystem for errors.", 2157 }}, 2158 MessageEntry{"ServiceFailure", 2159 { 2160 "Indicates that a service has exited unsuccessfully.", 2161 "Service %1 has exited unsuccessfully.", 2162 "Warning", 2163 1, 2164 {"string"}, 2165 "None.", 2166 }}, 2167 MessageEntry{"ServiceStarted", 2168 { 2169 "Indicates that a service has started successfully.", 2170 "Service %1 has started successfully.", 2171 "OK", 2172 1, 2173 {"string"}, 2174 "None.", 2175 }}, 2176 MessageEntry{"SparingRedundancyDegraded", 2177 { 2178 "Indicates the sparing redundancy state is degraded.", 2179 "Sparing redundancy state degraded. Socket=%1 " 2180 "Channel=%2 DIMM=%3 Domain=%4 Rank=%5.", 2181 "Warning", 2182 5, 2183 2184 { 2185 "number", 2186 "string", 2187 "number", 2188 "string", 2189 "number", 2190 }, 2191 "None.", 2192 }}, 2193 MessageEntry{ 2194 "SparingRedundancyFull", 2195 { 2196 "Indicates the sparing redundancy state is fully redundant.", 2197 "Sparing redundancy state fully redundant. Socket=%1 " 2198 "Channel=%2 DIMM=%3 Domain=%4 Rank=%5.", 2199 "OK", 2200 5, 2201 2202 { 2203 "number", 2204 "string", 2205 "number", 2206 "string", 2207 "number", 2208 }, 2209 "None.", 2210 }}, 2211 MessageEntry{"SsbThermalTrip", 2212 { 2213 "Indicates that an SSB Thermal trip has been asserted.", 2214 "SSB Thermal trip.", 2215 "Critical", 2216 0, 2217 {}, 2218 "None.", 2219 }}, 2220 MessageEntry{"SystemInterfaceDisabledProvisioned", 2221 { 2222 "Indicates that the system interface is in the disabled " 2223 "provisioned state. All commands are blocked to execute " 2224 "through the system interface.", 2225 "The system interface is in the disabled provisioned " 2226 "state.", 2227 "OK", 2228 0, 2229 {}, 2230 "None.", 2231 }}, 2232 MessageEntry{"SystemInterfaceUnprovisioned", 2233 { 2234 "Indicates that the system interface is in the " 2235 "unprovisioned state. All commands are permitted to " 2236 "execute through the system interface.", 2237 "The system interface is in the unprovisioned state.", 2238 "Critical", 2239 0, 2240 {}, 2241 "None.", 2242 }}, 2243 MessageEntry{"SystemInterfaceWhitelistProvisioned", 2244 { 2245 "Indicates that the system interface is in the whitelist " 2246 "provisioned state. Only whitelisted commands " 2247 "are permitted to execute through the system interface.", 2248 "The system interface is in the whitelist provisioned " 2249 "state.", 2250 "Warning", 2251 0, 2252 {}, 2253 "None.", 2254 }}, 2255 MessageEntry{"SystemPowerGoodFailed", 2256 { 2257 "Indicates that the system power good signal failed " 2258 "to assert within the specified time (VR failure).", 2259 "System power good failed to assert within %1 " 2260 "milliseconds (VR failure).", 2261 "Critical", 2262 1, 2263 {"number"}, 2264 "None.", 2265 }}, 2266 MessageEntry{"SystemPowerLost", 2267 { 2268 "Indicates that power was lost while the " 2269 "system was powered on.", 2270 "System Power Lost.", 2271 "Critical", 2272 0, 2273 {}, 2274 "None.", 2275 }}, 2276 MessageEntry{"SystemPowerOffFailed", 2277 { 2278 "Indicates that the system failed to power off.", 2279 "System Power-Off Failed.", 2280 "Critical", 2281 0, 2282 {}, 2283 "None.", 2284 }}, 2285 MessageEntry{"SystemPowerOnFailed", 2286 { 2287 "Indicates that the system failed to power on.", 2288 "System Power-On Failed.", 2289 "Critical", 2290 0, 2291 {}, 2292 "None.", 2293 }}, 2294 MessageEntry{ 2295 "VoltageRegulatorOverheated", 2296 { 2297 "Indicates that the specified voltage regulator overheated.", 2298 "%1 Voltage Regulator Overheated.", 2299 "Critical", 2300 1, 2301 {"string"}, 2302 "None.", 2303 }}, 2304 2305 }; 2306 } // namespace redfish::registries::openbmc 2307