1# dbus usage 2 3The following are guidelines for bmcweb's use of DBus to construct Redfish 4schemas: 5 6- Do not require (ie set 500 internal error on) an implementation present a 7 property that wasn't in the first commit of the interface unless it can be 8 verified that _all_ OpenBMC implementers of the interface support that 9 property. 10- If an implementation presents a property that doesn't match the type specified 11 by the interface at any version, it shall be reported as a 500 error. 12- If the DBus interface definition has an "unknown" or "unspecified" value, 13 detecting these will omit the property from the Redfish tree, in line with the 14 Redfish specification. 15- All DBus interfaces on all object paths are optional. An object missing an 16 interface is never an error, and shall simply omit the relevant properties 17 and/or actions from that Redfish Resource. 18- bmcweb will code to the DBus interface itself. This means that daemons are 19 expected to handle functionally bad, but DBus-correct input in their own 20 process, and return appropriate return codes. This is done to reduce the 21 duplication in input processing between the various user-facing daemons. 22- There are interfaces for which there is an expectation that there will only 23 ever be one producer in the project (ex bmc networking, user management). In 24 these cases, it is desirable to call the daemon by well known name directly. 25 Bmcweb APIs should call the mapper in cases where it's reasonably expected 26 that multiple implementations exist (ex, CPU management, Sensors). 27