xref: /openbmc/openbmc-test-automation/extended/code_update/host_code_update.robot (revision 287faaf22ed0a73c924a6df40c0e89e14faa67da)
19f74d3afSCharles Paul Hofer*** Settings ***
29f74d3afSCharles Paul HoferDocumentation     Update the PNOR code on a target BMC.
39f74d3afSCharles Paul Hofer...               Execution Method:
49f74d3afSCharles Paul Hofer...               python -m robot -v OPENBMC_HOST:<hostname>
59f74d3afSCharles Paul Hofer...               -v DELETE_OLD_PNOR_IMAGES:<"true" or "false">
6a5673166SCharles Paul Hofer...               -v IMAGE_FILE_PATH:<path/*.tar>
7a5673166SCharles Paul Hofer...               -v ALTERNATE_IMAGE_FILE_PATH:<path/*.tar>
8a5673166SCharles Paul Hofer...               host_code_update.robot
99f74d3afSCharles Paul Hofer...
109f74d3afSCharles Paul Hofer...               Code update method BMC
119f74d3afSCharles Paul Hofer...               Update work flow sequence:
129f74d3afSCharles Paul Hofer...                 - Upload image via REST
139f74d3afSCharles Paul Hofer...                 - Verify that the file exists on the BMC
149f74d3afSCharles Paul Hofer...                 - Check that software "Activation" is set to "Ready"
159f74d3afSCharles Paul Hofer...                 - Set "Requested Activation" to "Active"
169f74d3afSCharles Paul Hofer...                 - Wait for code update to complete
179f74d3afSCharles Paul Hofer...                 - Verify the new version
189f74d3afSCharles Paul Hofer
199f74d3afSCharles Paul HoferLibrary           ../../lib/bmc_ssh_utils.py
209f74d3afSCharles Paul HoferLibrary           ../../lib/code_update_utils.py
219f74d3afSCharles Paul HoferVariables         ../../data/variables.py
229f74d3afSCharles Paul HoferResource          ../../lib/boot_utils.robot
239f74d3afSCharles Paul HoferResource          code_update_utils.robot
249f74d3afSCharles Paul HoferResource          ../../lib/code_update_utils.robot
251eb85f57SGeorge KeishingResource          ../../lib/openbmc_ffdc.robot
269f74d3afSCharles Paul HoferResource          ../../lib/state_manager.robot
271eb85f57SGeorge KeishingResource          ../../lib/dump_utils.robot
289f74d3afSCharles Paul Hofer
290071549eSGeorge KeishingTest Teardown     Code Update Test Teardown
309f74d3afSCharles Paul Hofer
3109712a1eSGeorge KeishingForce Tags        Host_Code_Update
3209712a1eSGeorge Keishing
339f74d3afSCharles Paul Hofer*** Variables ***
349f74d3afSCharles Paul Hofer
359f74d3afSCharles Paul Hofer${QUIET}                          ${1}
369f74d3afSCharles Paul Hofer${IMAGE_FILE_PATH}                ${EMPTY}
379f74d3afSCharles Paul Hofer${DELETE_OLD_PNOR_IMAGES}         false
3851b54c08SCharles Paul Hofer${DELETE_OLD_GUARD_FILE}          false
39c1fa2bc9SCharles Paul Hofer${ALTERNATE_IMAGE_FILE_PATH}      ${EMPTY}
409f74d3afSCharles Paul Hofer
419f74d3afSCharles Paul Hofer*** Test Cases ***
429f74d3afSCharles Paul Hofer
439f74d3afSCharles Paul HoferREST Host Code Update
449f74d3afSCharles Paul Hofer    [Documentation]  Do a PNOR code update by uploading image on BMC via REST.
450071549eSGeorge Keishing    # 1. Delete error logs if there is any.
460071549eSGeorge Keishing    # 1. Do code update.
470071549eSGeorge Keishing    # 2. Do post update the following:
480071549eSGeorge Keishing    #    - Collect FFDC if error log exist and delete error logs.
499f74d3afSCharles Paul Hofer    [Tags]  REST_Host_Code_Update
509f74d3afSCharles Paul Hofer    [Setup]  Code Update Setup
519f74d3afSCharles Paul Hofer
528c7ada42SSweta Potthuri    Run Keyword And Ignore Error  List Installed Images  Host
538c7ada42SSweta Potthuri
549f74d3afSCharles Paul Hofer    Upload And Activate Image  ${IMAGE_FILE_PATH}
559f74d3afSCharles Paul Hofer    OBMC Reboot (off)
569f74d3afSCharles Paul Hofer
579f74d3afSCharles Paul Hofer
589f74d3afSCharles Paul HoferPost Update Boot To OS
599f74d3afSCharles Paul Hofer    [Documentation]  Boot the host OS
609f74d3afSCharles Paul Hofer    [Tags]  Post_Update_Boot_To_OS
610c4a87d0SCharles Paul Hofer    [Setup]  Start SOL Console Logging
62da6bace8SGeorge Keishing    [Teardown]  Run Keywords  Stop SOL Console Logging
63da6bace8SGeorge Keishing    ...         AND  Code Update Test Teardown
649f74d3afSCharles Paul Hofer
659f74d3afSCharles Paul Hofer    Run Keyword If  '${PREV_TEST_STATUS}' == 'FAIL'
669f74d3afSCharles Paul Hofer    ...  Fail  Code update failed. No need to boot to OS.
670071549eSGeorge Keishing    Delete Error Logs
689f74d3afSCharles Paul Hofer    REST Power On
69e43fb2f7SCharles Paul Hofer    Verify Running Host Image  ${IMAGE_FILE_PATH}
709f74d3afSCharles Paul Hofer
719f74d3afSCharles Paul Hofer
727c6e7520SCharles Paul HoferREST Host Code Update While OS Is Running
737c6e7520SCharles Paul Hofer    [Documentation]  Do a PNOR code update while the host is running.
747c6e7520SCharles Paul Hofer    [Tags]  REST_Host_Code_Update_While_OS_Is_Running
754e8c09b1SCharles Paul Hofer    [Teardown]  Run Keywords  REST Power Off  stack_mode=skip
764e8c09b1SCharles Paul Hofer    ...         AND  Code Update Test Teardown
777c6e7520SCharles Paul Hofer
787c6e7520SCharles Paul Hofer    Run Keyword If  '${PREV_TEST_STATUS}' == 'FAIL'
797c6e7520SCharles Paul Hofer    ...  Fail  Cannot boot the OS.
807c6e7520SCharles Paul Hofer
817c6e7520SCharles Paul Hofer    REST Power On  stack_mode=skip
8272373f88SGeorge Keishing    Upload And Activate Image
8372373f88SGeorge Keishing    ...  ${ALTERNATE_IMAGE_FILE_PATH}  skip_if_active=true
847c6e7520SCharles Paul Hofer    REST Power On  stack_mode=normal
857c6e7520SCharles Paul Hofer    Verify Running Host Image  ${ALTERNATE_IMAGE_FILE_PATH}
867c6e7520SCharles Paul Hofer
879f74d3afSCharles Paul HoferHost Image Priority Attribute Test
889f74d3afSCharles Paul Hofer    [Documentation]  Set "Priority" attribute.
899f74d3afSCharles Paul Hofer    [Tags]  Host_Image_Priority_Attribute_Test
909f74d3afSCharles Paul Hofer    [Template]  Temporarily Set PNOR Attribute
919f74d3afSCharles Paul Hofer
929f74d3afSCharles Paul Hofer    # Property        Value
939f74d3afSCharles Paul Hofer    Priority          ${0}
949f74d3afSCharles Paul Hofer    Priority          ${1}
959f74d3afSCharles Paul Hofer    Priority          ${127}
9697ecb270SGeorge Keishing    Priority          ${255}
979f74d3afSCharles Paul Hofer
989f74d3afSCharles Paul Hofer
9942f17468SCharles Paul HoferHost Set Priority To Invalid Values
10042f17468SCharles Paul Hofer    [Documentation]  Attempt to set the priority of an image to an invalid
10142f17468SCharles Paul Hofer    ...              value and expect an error.
10242f17468SCharles Paul Hofer    [Tags]  Host_Set_Priority_To_Invalid_Values
10342f17468SCharles Paul Hofer    [Template]  Set Priority To Invalid Value And Expect Error
10442f17468SCharles Paul Hofer
10542f17468SCharles Paul Hofer    # Version Type              Priority
10642f17468SCharles Paul Hofer    ${VERSION_PURPOSE_HOST}    ${-1}
10742f17468SCharles Paul Hofer    ${VERSION_PURPOSE_HOST}    ${256}
10842f17468SCharles Paul Hofer
10942f17468SCharles Paul Hofer
1109f74d3afSCharles Paul HoferSet RequestedActivation To None
1119f74d3afSCharles Paul Hofer    [Documentation]  Set the RequestedActivation of the image to None and
1129f74d3afSCharles Paul Hofer    ...              verify that it is in fact set to None.
1139f74d3afSCharles Paul Hofer    [Tags]  Set_RequestedActivation_To_None
1149f74d3afSCharles Paul Hofer
1159f74d3afSCharles Paul Hofer    ${software_objects}=  Get Software Objects
1169f74d3afSCharles Paul Hofer    Set Host Software Property  @{software_objects}[0]  RequestedActivation
1179f74d3afSCharles Paul Hofer    ...  ${REQUESTED_NONE}
1189f74d3afSCharles Paul Hofer    ${software_properties}=  Get Host Software Property  @{software_objects}[0]
1199f74d3afSCharles Paul Hofer    Should Be Equal As Strings  &{software_properties}[RequestedActivation]
1209f74d3afSCharles Paul Hofer    ...  ${REQUESTED_NONE}
1219f74d3afSCharles Paul Hofer
1229f74d3afSCharles Paul Hofer
1239f74d3afSCharles Paul HoferSet RequestedActivation And Activation To Invalid Value
1249f74d3afSCharles Paul Hofer    [Documentation]  Set the RequestedActivation and Activation propreties of
1259f74d3afSCharles Paul Hofer    ...              the image to an invalid value and verify that it was not
1269f74d3afSCharles Paul Hofer    ...              changed.
1279f74d3afSCharles Paul Hofer    [Template]  Set Property To Invalid Value And Verify No Change
1289f74d3afSCharles Paul Hofer    [Tags]  Set_RequestedActivation_And_Activation_To_Invalid_Value
1299f74d3afSCharles Paul Hofer
1309f74d3afSCharles Paul Hofer    # Property              Version Type
1319f74d3afSCharles Paul Hofer    RequestedActivation     ${VERSION_PURPOSE_HOST}
1329f74d3afSCharles Paul Hofer    Activation              ${VERSION_PURPOSE_HOST}
1339f74d3afSCharles Paul Hofer
1349f74d3afSCharles Paul Hofer
135c1fa2bc9SCharles Paul HoferUpload And Activate Multiple Host Images
136c1fa2bc9SCharles Paul Hofer    [Documentation]  Upload another PNOR image and verify that its state is
137c1fa2bc9SCharles Paul Hofer    ...              different from all others.
138c1fa2bc9SCharles Paul Hofer    [Tags]  Upload_And_Activate_Multiple_Host_Images
139c1fa2bc9SCharles Paul Hofer    [Template]  Activate Image And Verify No Duplicate Priorities
140c1fa2bc9SCharles Paul Hofer    [Setup]  Upload And Activate Multiple BMC Images Setup
141c1fa2bc9SCharles Paul Hofer
142c1fa2bc9SCharles Paul Hofer    # Image File Path              Image Purpose
143c1fa2bc9SCharles Paul Hofer    ${ALTERNATE_IMAGE_FILE_PATH}   ${VERSION_PURPOSE_HOST}
144c1fa2bc9SCharles Paul Hofer
145c1fa2bc9SCharles Paul Hofer
146a5673166SCharles Paul HoferSet Same Priority For Multiple Host Images
147a5673166SCharles Paul Hofer    [Documentation]  Attempt to set the priority to be the same for two PNOR
148a5673166SCharles Paul Hofer    ...              images and verify that the priorities are not the same.
149a5673166SCharles Paul Hofer    [Tags]  Set_Same_Priority_For_Multiple_Host_Images
150a5673166SCharles Paul Hofer
151a5673166SCharles Paul Hofer    Run Keyword If  '${PREV_TEST_STATUS}' == 'FAIL'
152a5673166SCharles Paul Hofer    ...  Fail  Activation of alternate image failed. Cannot set priority.
153a5673166SCharles Paul Hofer    Set Same Priority For Multiple Images  ${VERSION_PURPOSE_HOST}
154a5673166SCharles Paul Hofer
155a5673166SCharles Paul Hofer
1569f74d3afSCharles Paul HoferDelete Host Image
1579f74d3afSCharles Paul Hofer    [Documentation]  Delete a PNOR image from the BMC and PNOR flash chip.
1589f74d3afSCharles Paul Hofer    [Tags]  Delete_Host_Image
1599f74d3afSCharles Paul Hofer    [Setup]  Initiate Host PowerOff
1609f74d3afSCharles Paul Hofer
1619f74d3afSCharles Paul Hofer    ${software_objects}=  Get Software Objects
1629f74d3afSCharles Paul Hofer    ...  version_type=${VERSION_PURPOSE_HOST}
1639f74d3afSCharles Paul Hofer    ${num_images}=  Get Length  ${software_objects}
1649f74d3afSCharles Paul Hofer    Should Be True  0 < ${num_images}
1659f74d3afSCharles Paul Hofer    ...  msg=There are no PNOR images on the BMC to delete.
1669f74d3afSCharles Paul Hofer    Delete Image And Verify  @{software_objects}[0]  ${VERSION_PURPOSE_HOST}
1679f74d3afSCharles Paul Hofer
1689f74d3afSCharles Paul Hofer
169*287faaf2SGeorge KeishingVerify Host Update When Host Reboot During Activation In Progress
170*287faaf2SGeorge Keishing    [Documentation]  Attempt to reboot the host while an image is activating.
171*287faaf2SGeorge Keishing    [Tags]  Verify_Host_Update_When_Host_Reboot_During_Activation_In_Progress
172*287faaf2SGeorge Keishing
173*287faaf2SGeorge Keishing    Upload And Activate Image  ${IMAGE_FILE_PATH}
174*287faaf2SGeorge Keishing    REST Power On
175*287faaf2SGeorge Keishing    Delete Error Logs
176*287faaf2SGeorge Keishing
177*287faaf2SGeorge Keishing    ${version_id}=  Upload And Activate Image  ${ALTERNATE_IMAGE_FILE_PATH}
178*287faaf2SGeorge Keishing    ...  wait=${0}
179*287faaf2SGeorge Keishing
180*287faaf2SGeorge Keishing    ${resp}=  OpenBMC Get Request  ${SOFTWARE_VERSION_URI}${version_id}
181*287faaf2SGeorge Keishing    Should Be Equal As Strings  ${resp.status_code}  ${HTTP_OK}
182*287faaf2SGeorge Keishing
183*287faaf2SGeorge Keishing    # Reboot Host during activation.
184*287faaf2SGeorge Keishing    Host Reboot
185*287faaf2SGeorge Keishing
186*287faaf2SGeorge Keishing    Wait For Activation State Change  ${version_id}  ${ACTIVATING}
187*287faaf2SGeorge Keishing
188*287faaf2SGeorge Keishing    # New image priority should be 0.
189*287faaf2SGeorge Keishing    ${new_host_properties}=
190*287faaf2SGeorge Keishing    ...  Get Host Software Property  ${SOFTWARE_VERSION_URI}${version_id}
191*287faaf2SGeorge Keishing    Should Be Equal As Integers  ${new_host_properties["Priority"]}  ${0}
192*287faaf2SGeorge Keishing
193*287faaf2SGeorge Keishing    # Reboot host to boot up with the new host image version.
194*287faaf2SGeorge Keishing    Host Reboot
195*287faaf2SGeorge Keishing    Verify Running Host Image  ${ALTERNATE_IMAGE_FILE_PATH}
196*287faaf2SGeorge Keishing
197*287faaf2SGeorge Keishing
1989f74d3afSCharles Paul Hofer*** Keywords ***
1999f74d3afSCharles Paul Hofer
2009f74d3afSCharles Paul HoferTemporarily Set PNOR Attribute
2019f74d3afSCharles Paul Hofer    [Documentation]  Update the PNOR attribute value.
2029f74d3afSCharles Paul Hofer    [Arguments]  ${attribute_name}  ${attribute_value}
2039f74d3afSCharles Paul Hofer
2049f74d3afSCharles Paul Hofer    # Description of argument(s):
2059f74d3afSCharles Paul Hofer    # attribute_name    Host software attribute name (e.g. "Priority").
2069f74d3afSCharles Paul Hofer    # attribute_value   Value to be written.
2079f74d3afSCharles Paul Hofer
2089f74d3afSCharles Paul Hofer    ${image_ids}=  Get Software Objects
2099f74d3afSCharles Paul Hofer    ${init_host_properties}=  Get Host Software Property  ${image_ids[0]}
2109f74d3afSCharles Paul Hofer    ${initial_priority}=  Set Variable  ${init_host_properties["Priority"]}
2119f74d3afSCharles Paul Hofer
2129f74d3afSCharles Paul Hofer    Set Host Software Property  ${image_ids[0]}  ${attribute_name}
2139f74d3afSCharles Paul Hofer    ...  ${attribute_value}
2149f74d3afSCharles Paul Hofer
2159f74d3afSCharles Paul Hofer    ${cur_host_properties}=  Get Host Software Property  ${image_ids[0]}
2169f74d3afSCharles Paul Hofer    Should Be Equal As Integers  ${cur_host_properties["Priority"]}
2179f74d3afSCharles Paul Hofer    ...  ${attribute_value}
2189f74d3afSCharles Paul Hofer
2199f74d3afSCharles Paul Hofer    # Revert to to initial value.
2209f74d3afSCharles Paul Hofer    Set Host Software Property
2219f74d3afSCharles Paul Hofer    ...  ${image_ids[0]}  ${attribute_name}  ${initial_priority}
2229f74d3afSCharles Paul Hofer
2239f74d3afSCharles Paul Hofer
2249f74d3afSCharles Paul HoferCode Update Setup
2259f74d3afSCharles Paul Hofer    [Documentation]  Do code update test case setup.
2261eb85f57SGeorge Keishing    # - Clean up all existing BMC dumps.
2271eb85f57SGeorge Keishing    # - Clean up all currently install PNOR images.
2289f74d3afSCharles Paul Hofer
229b926408eSCharles Paul Hofer    Run Keyword And Ignore Error  Smart Power Off
2301eb85f57SGeorge Keishing    Delete All Dumps
2310071549eSGeorge Keishing    Delete Error Logs
2329f74d3afSCharles Paul Hofer    Run Keyword If  'true' == '${DELETE_OLD_PNOR_IMAGES}'
2339f74d3afSCharles Paul Hofer    ...  Delete All PNOR Images
23451b54c08SCharles Paul Hofer    Run Keyword If  'true' == '${DELETE_OLD_GUARD_FILE}'  BMC Execute Command
23551b54c08SCharles Paul Hofer    ...  rm -f /var/lib/phosphor-software-manager/pnor/prsv/GUARD
2369f74d3afSCharles Paul Hofer
2379f74d3afSCharles Paul Hofer
238c1fa2bc9SCharles Paul HoferUpload And Activate Multiple BMC Images Setup
239c1fa2bc9SCharles Paul Hofer    [Documentation]  Check that the ALTERNATE_FILE_PATH variable is set.
240c1fa2bc9SCharles Paul Hofer
241c1fa2bc9SCharles Paul Hofer    Should Not Be Empty  ${ALTERNATE_IMAGE_FILE_PATH}
2424e8c09b1SCharles Paul Hofer    Delete All PNOR Images
24372373f88SGeorge Keishing    Upload And Activate Image  ${IMAGE_FILE_PATH}  skip_if_active=true
244c1fa2bc9SCharles Paul Hofer
2459f74d3afSCharles Paul HoferGet PNOR Extended Version
2469f74d3afSCharles Paul Hofer    [Documentation]  Return the PNOR extended version.
2479f74d3afSCharles Paul Hofer    [Arguments]  ${manifest_path}
2489f74d3afSCharles Paul Hofer
2499f74d3afSCharles Paul Hofer    # Description of argument(s):
2509f74d3afSCharles Paul Hofer    # manifest_path  Path of the MANIFEST file
2519f74d3afSCharles Paul Hofer    #                (e.g. "/tmp/images/abc123/MANIFEST").
2529f74d3afSCharles Paul Hofer
2539f74d3afSCharles Paul Hofer    ${version}= BMC Execute Command
2549f74d3afSCharles Paul Hofer    ...  grep extended_version= ${manifest_path}
2559f74d3afSCharles Paul Hofer    [return] ${version.split(",")}
2560071549eSGeorge Keishing
2570071549eSGeorge Keishing
2580071549eSGeorge KeishingCode Update Test Teardown
2590071549eSGeorge Keishing    [Documentation]  Do code update test case teardown.
2600071549eSGeorge Keishing    # 1. Collect FFDC if test case failed.
2610071549eSGeorge Keishing    # 2. Collect FFDC if test PASS but error log exists.
2620071549eSGeorge Keishing
2630071549eSGeorge Keishing    FFDC On Test Case Fail
2640071549eSGeorge Keishing    Run Keyword If  '${TEST_STATUS}' == 'PASS'  Check Error And Collect FFDC