1*3f57fe28SNick CrewsWhat: /sys/class/power_supply/wilco-charger/charge_type 2*3f57fe28SNick CrewsDate: April 2019 3*3f57fe28SNick CrewsKernelVersion: 5.2 4*3f57fe28SNick CrewsDescription: 5*3f57fe28SNick Crews What charging algorithm to use: 6*3f57fe28SNick Crews 7*3f57fe28SNick Crews Standard: Fully charges battery at a standard rate. 8*3f57fe28SNick Crews Adaptive: Battery settings adaptively optimized based on 9*3f57fe28SNick Crews typical battery usage pattern. 10*3f57fe28SNick Crews Fast: Battery charges over a shorter period. 11*3f57fe28SNick Crews Trickle: Extends battery lifespan, intended for users who 12*3f57fe28SNick Crews primarily use their Chromebook while connected to AC. 13*3f57fe28SNick Crews Custom: A low and high threshold percentage is specified. 14*3f57fe28SNick Crews Charging begins when level drops below 15*3f57fe28SNick Crews charge_control_start_threshold, and ceases when 16*3f57fe28SNick Crews level is above charge_control_end_threshold. 17*3f57fe28SNick Crews 18*3f57fe28SNick CrewsWhat: /sys/class/power_supply/wilco-charger/charge_control_start_threshold 19*3f57fe28SNick CrewsDate: April 2019 20*3f57fe28SNick CrewsKernelVersion: 5.2 21*3f57fe28SNick CrewsDescription: 22*3f57fe28SNick Crews Used when charge_type="Custom", as described above. Measured in 23*3f57fe28SNick Crews percentages. The valid range is [50, 95]. 24*3f57fe28SNick Crews 25*3f57fe28SNick CrewsWhat: /sys/class/power_supply/wilco-charger/charge_control_end_threshold 26*3f57fe28SNick CrewsDate: April 2019 27*3f57fe28SNick CrewsKernelVersion: 5.2 28*3f57fe28SNick CrewsDescription: 29*3f57fe28SNick Crews Used when charge_type="Custom", as described above. Measured in 30*3f57fe28SNick Crews percentages. The valid range is [55, 100]. 31