Home
last modified time | relevance | path

Searched refs:crossed (Results 1 – 25 of 37) sorted by relevance

12

/openbmc/linux/Documentation/devicetree/bindings/display/tilcdc/
H A Dtilcdc.txt20 - blue-and-red-wiring: Recognized values "straight" or "crossed".
25 - "crossed" indicates wiring that has blue and red wires
26 crossed. This setup supports BGR565, RGB888 and XRGB8888
46 crossed and LCD_DATA[0:4] is for Red[3:7] and LCD_DATA[11:15] is
60 blue-and-red-wiring = "crossed";
/openbmc/linux/Documentation/admin-guide/media/
H A Dsi476x.rst42 crossed below the blend threshold
116 0x00 multhint 0 - multipath value has not crossed
118 1 - multipath value has crossed
122 crossed high threshold
124 crossed high threshold
/openbmc/linux/Documentation/hwmon/
H A Dadc128d818.rst25 When the HOT Temperature Limit is crossed, this will cause an alarm that will
32 An alarm is triggered if the voltage has crossed a programmable minimum
H A Dsis5595.rst87 when the max is crossed; it is also triggered when it drops below the min
99 alarm is triggered if the voltage has crossed a programmable minimum or
106 triggered when an external chip has crossed its limits. Usually, this is
H A Dlm80.rst44 which operate independently. When the HOT Temperature Limit is crossed,
60 An alarm is triggered if the voltage has crossed a programmable minimum
H A Dlm78.rst46 when the Overtemperature Shutdown limit is crossed; it is triggered again
61 An alarm is triggered if the voltage has crossed a programmable minimum
H A Dvia686a.rst49 when the Overtemperature Shutdown limit is crossed; it is triggered again
60 An alarm is triggered if the voltage has crossed a programmable minimum
H A Dw83l786ng.rst43 An alarm is triggered if the voltage has crossed a programmable minimum
H A Dbt1-pvt.rst57 has associated min and max limits which trigger an alarm when crossed.
74 have associated min and max limits which trigger an alarm when crossed.
H A Ddme1737.rst134 when crossed.
152 when crossed. Additionally, each temperature input has a fault attribute that
162 alarm when crossed. Fan inputs 1-4 provide type attributes that need to be set
H A Dpc87360.rst128 alarm when crossed.
165 triggers an alarm when crossed.
H A Dvt1211.rst112 alarm when crossed.
119 has a high limit which triggers an alarm if crossed. There is an associated
H A Dlm87.rst55 volts. An alarm is triggered if the voltage has crossed a programmable
H A Dgl518sm.rst59 An alarm is triggered if the voltage has crossed a programmable minimum or
H A Dadm1021.rst116 Each sensor has its own low and high limits. When they are crossed, the
H A Dadm1026.rst66 crossed a programmable minimum or maximum limit. Note that minimum in this
H A Dit87.rst284 when the Overtemperature Shutdown limit is crossed.
295 alarm is triggered if the voltage has crossed a programmable minimum or
H A Dw83792d.rst69 An alarm is triggered if the voltage has crossed a programmable minimum
H A Dw83791d.rst81 An alarm is triggered if the voltage has crossed a programmable minimum
H A Df71805f.rst107 triggers an alarm when crossed.
/openbmc/linux/fs/xfs/scrub/
H A Dagheader_repair.c456 struct xagb_bitmap crossed; member
515 error = xagb_bitmap_set(&ra->crossed, agbno, 1); in xrep_agfl_check_extent()
552 xagb_bitmap_init(&ra.crossed); in xrep_agfl_collect_blocks()
591 error = xagb_bitmap_disunion(agfl_extents, &ra.crossed); in xrep_agfl_collect_blocks()
603 xagb_bitmap_destroy(&ra.crossed); in xrep_agfl_collect_blocks()
/openbmc/u-boot/drivers/thermal/
H A DKconfig18 passive trip is crossed.
/openbmc/linux/drivers/thermal/
H A DKconfig26 trip point crossed, cooling device update or governor
120 The Userspace governor allows to get trip point crossed
254 CPUs when the passive trip is crossed.
266 passive trip is crossed.
287 trip is crossed.
318 passive trip is crossed.
/openbmc/linux/drivers/thunderbolt/
H A DKconfig51 dongle that has TX/RX lines crossed, or by simply connecting a
/openbmc/linux/arch/arm/boot/dts/ti/omap/
H A Dam335x-boneblack-hdmi.dtsi58 * below to "crossed" and uncomment the video-ports -property

12