Home
last modified time | relevance | path

Searched hist:d4f408cdcd26921c1268cb8dcbe8ffb6faf837f3 (Results 1 – 1 of 1) sorted by relevance

/openbmc/linux/drivers/power/supply/
H A Daxp20x_battery.cdiff d4f408cdcd26921c1268cb8dcbe8ffb6faf837f3 Wed Jan 12 02:47:27 CST 2022 Evgeny Boger <boger@wirenboard.com> power: supply: axp20x_battery: properly report current when discharging

As stated in [1], negative current values are used for discharging
batteries.

AXP PMICs internally have two different ADC channels for shunt current
measurement: one used during charging and one during discharging.
The values reported by these ADCs are unsigned.
While the driver properly selects ADC channel to get the data from,
it doesn't apply negative sign when reporting discharging current.

[1] Documentation/ABI/testing/sysfs-class-power

Signed-off-by: Evgeny Boger <boger@wirenboard.com>
Acked-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>