H A Dpsu_manager.hppdiff b7131a12ee603264a90b55dd7afde929434424e9 Thu Oct 26 19:38:45 CDT 2023 Faisal Awada <faisal@us.ibm.com> psu-ng: Fixed PSU monitor app to bind/unbind device driver appropriately.

Modified bindOrUnbind function:
Bind the device driver when the PSU present and i2cbus-i2caddr
does not exist. Unbind the device driver when i2cbus-i2caddr exists
and the PSU not present.

bindOrUnbind does not do anything when:
* PSU device driver bind exist and the device present
* PSU device driver bind does not exist and device not present

Added new function populateDriverName:
Search for device driver name in all PSUs, then assign the device
driver name to all PSUs including missing PSUs.

Testing:
Verified in the following test, there is no bind/unbind error log.
1 - Removed 1 PSU and powered on the BMC with 3 PSUs
2 - Use step 1, after power on plugged in the 4th PSU and verified
/sys/bus/i2c/drivers/-ibm-cffps/3-006b exist
3 - Removed 2 PSUs and powered on the BMC with 2 PSUs.
4 - Use step 3, after power on plugged in the missing PSUs, verified
bind/Unbind /sys/bus/i2c/drivers/-ibm-cffps/3-006x for appropriate PSU.
5 - Powered on system with 4 PSUs then removed 2 PSUs. Verified
unbind done for appropriate PSU.

Change-Id: I325fc0dbb16f9c3b582b739e8440a74e34aae753
Signed-off-by: Faisal Awada <faisal@us.ibm.com>
H A Dpower_supply.hppdiff b7131a12ee603264a90b55dd7afde929434424e9 Thu Oct 26 19:38:45 CDT 2023 Faisal Awada <faisal@us.ibm.com> psu-ng: Fixed PSU monitor app to bind/unbind device driver appropriately.

Modified bindOrUnbind function:
Bind the device driver when the PSU present and i2cbus-i2caddr
does not exist. Unbind the device driver when i2cbus-i2caddr exists
and the PSU not present.

bindOrUnbind does not do anything when:
* PSU device driver bind exist and the device present
* PSU device driver bind does not exist and device not present

Added new function populateDriverName:
Search for device driver name in all PSUs, then assign the device
driver name to all PSUs including missing PSUs.

Testing:
Verified in the following test, there is no bind/unbind error log.
1 - Removed 1 PSU and powered on the BMC with 3 PSUs
2 - Use step 1, after power on plugged in the 4th PSU and verified
/sys/bus/i2c/drivers/-ibm-cffps/3-006b exist
3 - Removed 2 PSUs and powered on the BMC with 2 PSUs.
4 - Use step 3, after power on plugged in the missing PSUs, verified
bind/Unbind /sys/bus/i2c/drivers/-ibm-cffps/3-006x for appropriate PSU.
5 - Powered on system with 4 PSUs then removed 2 PSUs. Verified
unbind done for appropriate PSU.

Change-Id: I325fc0dbb16f9c3b582b739e8440a74e34aae753
Signed-off-by: Faisal Awada <faisal@us.ibm.com>
H A Dpower_supply.cppdiff b7131a12ee603264a90b55dd7afde929434424e9 Thu Oct 26 19:38:45 CDT 2023 Faisal Awada <faisal@us.ibm.com> psu-ng: Fixed PSU monitor app to bind/unbind device driver appropriately.

Modified bindOrUnbind function:
Bind the device driver when the PSU present and i2cbus-i2caddr
does not exist. Unbind the device driver when i2cbus-i2caddr exists
and the PSU not present.

bindOrUnbind does not do anything when:
* PSU device driver bind exist and the device present
* PSU device driver bind does not exist and device not present

Added new function populateDriverName:
Search for device driver name in all PSUs, then assign the device
driver name to all PSUs including missing PSUs.

Testing:
Verified in the following test, there is no bind/unbind error log.
1 - Removed 1 PSU and powered on the BMC with 3 PSUs
2 - Use step 1, after power on plugged in the 4th PSU and verified
/sys/bus/i2c/drivers/-ibm-cffps/3-006b exist
3 - Removed 2 PSUs and powered on the BMC with 2 PSUs.
4 - Use step 3, after power on plugged in the missing PSUs, verified
bind/Unbind /sys/bus/i2c/drivers/-ibm-cffps/3-006x for appropriate PSU.
5 - Powered on system with 4 PSUs then removed 2 PSUs. Verified
unbind done for appropriate PSU.

Change-Id: I325fc0dbb16f9c3b582b739e8440a74e34aae753
Signed-off-by: Faisal Awada <faisal@us.ibm.com>
H A Dpsu_manager.cppdiff b7131a12ee603264a90b55dd7afde929434424e9 Thu Oct 26 19:38:45 CDT 2023 Faisal Awada <faisal@us.ibm.com> psu-ng: Fixed PSU monitor app to bind/unbind device driver appropriately.

Modified bindOrUnbind function:
Bind the device driver when the PSU present and i2cbus-i2caddr
does not exist. Unbind the device driver when i2cbus-i2caddr exists
and the PSU not present.

bindOrUnbind does not do anything when:
* PSU device driver bind exist and the device present
* PSU device driver bind does not exist and device not present

Added new function populateDriverName:
Search for device driver name in all PSUs, then assign the device
driver name to all PSUs including missing PSUs.

Testing:
Verified in the following test, there is no bind/unbind error log.
1 - Removed 1 PSU and powered on the BMC with 3 PSUs
2 - Use step 1, after power on plugged in the 4th PSU and verified
/sys/bus/i2c/drivers/-ibm-cffps/3-006b exist
3 - Removed 2 PSUs and powered on the BMC with 2 PSUs.
4 - Use step 3, after power on plugged in the missing PSUs, verified
bind/Unbind /sys/bus/i2c/drivers/-ibm-cffps/3-006x for appropriate PSU.
5 - Powered on system with 4 PSUs then removed 2 PSUs. Verified
unbind done for appropriate PSU.

Change-Id: I325fc0dbb16f9c3b582b739e8440a74e34aae753