Home
last modified time | relevance | path

Searched hist:"78 e86012f4aa1fcc53a526c402df5d017d43eb48" (Results 1 – 9 of 9) sorted by relevance

/openbmc/openpower-occ-control/
H A Docc_command.cppdiff 78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
H A Docc_command.hppdiff 78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
H A Docc_device.hppdiff 78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
H A Dpowermode.hpp78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
H A Dpowermode.cpp78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
H A Docc_status.cppdiff 78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
H A Docc_manager.hppdiff 78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
H A Docc_status.hppdiff 78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
H A Docc_manager.cppdiff 78e86012f4aa1fcc53a526c402df5d017d43eb48 Thu Mar 04 16:15:31 CST 2021 Chris Cain <cjcain@us.ibm.com> Send OCC mode change and IPS parms after reaching active state

Change is only applicable for POWER10 PowerVM systems.
Send mode change requests to OCC when PowerMode is changed.
Retry OCC command once, if a valid response is not received.

Tested: built openpower-occ-control successfully and verified
functionality on hardware.

Change-Id: If375f8abfdb2ad82937b8744096c2ccc471263d2
Signed-off-by: Chris Cain <cjcain@us.ibm.com>