H A D | meson.options | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
H A D | README.md | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
H A D | meson.build | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
/openbmc/phosphor-psu-code-mgmt/test/ |
H A D | mocked_utils.hpp | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
H A D | test_activation.cpp | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
H A D | test_item_updater.cpp | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
/openbmc/phosphor-psu-code-mgmt/src/ |
H A D | utils.hpp | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
H A D | utils.cpp | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
H A D | item_updater.hpp | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
H A D | activation.cpp | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|
H A D | item_updater.cpp | diff 783406e649e90e13540f192f4111270a02d83168 Sun Nov 17 21:49:37 CST 2024 Shawn McCarney <shawnmm@us.ibm.com> Get model using command line tool
Get the PSU model using a command line tool specified in the meson options. The default tool is 'psutils --get-model'. The tool should get the model data directly from the PSU.
This is more accurate than getting the Model property of the Asset interface on D-Bus. Inventory Manager saves its state to files. When the BMC is booted, Inventory Manager initializes itself using the saved state. This is necessary to handle the scenario where the BMC is rebooted while the rest of the system is powered on (such as a concurrent BMC code update).
However, if all power was removed from the system, a PSU may have been added/removed/replaced while the BMC was offline. When the BMC boots, the Inventory Manager saved state is not correct.
Eventually the PSU monitoring application will update the model on D-Bus, but this can take a non-trivial amount of time. This is especially true if EntityManager is used to provide the PSU bus and address information to the PSU monitoring application.
Tested: * Verified all automated tests build and run successfully * Verified application uses command line tool to obtain model * Verified command line tool was returning the correct model * Test where command line tool fails with non-zero exit code * Tested where all PSU information available when application starts * Tested where PSU information is obtained after application starts using the InterfacesAdded handler * Tested where PSU presence changes and is obtained by the PropertiesChanged handler * Full test plan is available at https://gist.github.com/smccarney/87bd821a6d317ec0915d1f162028ff01
Change-Id: Ia9d35850aa6ac27dd006679991272232d67390ff Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
|