Searched hist:"5 a64f775691647c242aa40d34f3512e7b179a921" (Results 1 – 3 of 3) sorted by relevance
/openbmc/linux/Documentation/driver-api/thermal/ |
H A D | power_allocator.rst | diff 5a64f775691647c242aa40d34f3512e7b179a921 Tue Nov 03 03:05:58 CST 2020 Lukasz Luba <lukasz.luba@arm.com> PM: EM: Clarify abstract scale usage for power values in Energy Model
The Energy Model (EM) can store power values in milli-Watts or in abstract scale. This might cause issues in the subsystems which use the EM for estimating the device power, such as:
- mixing of different scales in a subsystem which uses multiple (cooling) devices (e.g. thermal Intelligent Power Allocation (IPA))
- assuming that energy [milli-Joules] can be derived from the EM power values which might not be possible since the power scale doesn't have to be in milli-Watts
To avoid misconfiguration add the requisite documentation to the EM and related subsystems: EAS and IPA.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
|
/openbmc/linux/Documentation/scheduler/ |
H A D | sched-energy.rst | diff 5a64f775691647c242aa40d34f3512e7b179a921 Tue Nov 03 03:05:58 CST 2020 Lukasz Luba <lukasz.luba@arm.com> PM: EM: Clarify abstract scale usage for power values in Energy Model
The Energy Model (EM) can store power values in milli-Watts or in abstract scale. This might cause issues in the subsystems which use the EM for estimating the device power, such as:
- mixing of different scales in a subsystem which uses multiple (cooling) devices (e.g. thermal Intelligent Power Allocation (IPA))
- assuming that energy [milli-Joules] can be derived from the EM power values which might not be possible since the power scale doesn't have to be in milli-Watts
To avoid misconfiguration add the requisite documentation to the EM and related subsystems: EAS and IPA.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
|
/openbmc/linux/Documentation/power/ |
H A D | energy-model.rst | diff 5a64f775691647c242aa40d34f3512e7b179a921 Tue Nov 03 03:05:58 CST 2020 Lukasz Luba <lukasz.luba@arm.com> PM: EM: Clarify abstract scale usage for power values in Energy Model
The Energy Model (EM) can store power values in milli-Watts or in abstract scale. This might cause issues in the subsystems which use the EM for estimating the device power, such as:
- mixing of different scales in a subsystem which uses multiple (cooling) devices (e.g. thermal Intelligent Power Allocation (IPA))
- assuming that energy [milli-Joules] can be derived from the EM power values which might not be possible since the power scale doesn't have to be in milli-Watts
To avoid misconfiguration add the requisite documentation to the EM and related subsystems: EAS and IPA.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
|