Searched hist:"4 c62fc777c2932b32a9225ec99177883e4412c5b" (Results 1 – 4 of 4) sorted by relevance
/openbmc/phosphor-fan-presence/monitor/test/ |
H A D | power_off_cause_test.cpp | diff 4c62fc777c2932b32a9225ec99177883e4412c5b Wed Feb 14 16:10:19 CST 2024 Matt Spinler <spinler@us.ibm.com> monitor: Add fan_frus_with_nonfunc_rotors cause
Create a new power off rule to power off when a specific number of fan FRUs have nonfunctional rotors. With this rule failing rotors can be treated differently when they are spread across fans FRUS than when they are within the same fan FRU.
For example, if both rotors of a 2 rotor fan fail the system can stay up, but if 2 rotors in separate fans fail then the system could be made to power off.
Signed-off-by: Matt Spinler <spinler@us.ibm.com> Change-Id: Ia1d13596a9e8a6e3a361e5b631699a3c80e36fb8
|
/openbmc/phosphor-fan-presence/monitor/ |
H A D | power_off_cause.hpp | diff 4c62fc777c2932b32a9225ec99177883e4412c5b Wed Feb 14 16:10:19 CST 2024 Matt Spinler <spinler@us.ibm.com> monitor: Add fan_frus_with_nonfunc_rotors cause
Create a new power off rule to power off when a specific number of fan FRUs have nonfunctional rotors. With this rule failing rotors can be treated differently when they are spread across fans FRUS than when they are within the same fan FRU.
For example, if both rotors of a 2 rotor fan fail the system can stay up, but if 2 rotors in separate fans fail then the system could be made to power off.
Signed-off-by: Matt Spinler <spinler@us.ibm.com> Change-Id: Ia1d13596a9e8a6e3a361e5b631699a3c80e36fb8
|
H A D | json_parser.cpp | diff 4c62fc777c2932b32a9225ec99177883e4412c5b Wed Feb 14 16:10:19 CST 2024 Matt Spinler <spinler@us.ibm.com> monitor: Add fan_frus_with_nonfunc_rotors cause
Create a new power off rule to power off when a specific number of fan FRUs have nonfunctional rotors. With this rule failing rotors can be treated differently when they are spread across fans FRUS than when they are within the same fan FRU.
For example, if both rotors of a 2 rotor fan fail the system can stay up, but if 2 rotors in separate fans fail then the system could be made to power off.
Signed-off-by: Matt Spinler <spinler@us.ibm.com> Change-Id: Ia1d13596a9e8a6e3a361e5b631699a3c80e36fb8
|
/openbmc/phosphor-fan-presence/docs/monitor/ |
H A D | power_off_config.md | diff 4c62fc777c2932b32a9225ec99177883e4412c5b Wed Feb 14 16:10:19 CST 2024 Matt Spinler <spinler@us.ibm.com> monitor: Add fan_frus_with_nonfunc_rotors cause
Create a new power off rule to power off when a specific number of fan FRUs have nonfunctional rotors. With this rule failing rotors can be treated differently when they are spread across fans FRUS than when they are within the same fan FRU.
For example, if both rotors of a 2 rotor fan fail the system can stay up, but if 2 rotors in separate fans fail then the system could be made to power off.
Signed-off-by: Matt Spinler <spinler@us.ibm.com> Change-Id: Ia1d13596a9e8a6e3a361e5b631699a3c80e36fb8
|