/openbmc/bmcweb/redfish-core/include/generated/enums/ |
H A D | pump.hpp | 12 Liquid, enumerator 24 {PumpType::Liquid, "Liquid"},
|
/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema/ |
H A D | CoolantConnector.v1_1_0.json | 36 …"description": "The `CoolantConnector` schema describes a liquid coolant connector, including any … 185 "description": "The desired liquid flow rate (L/min).", 187 …"longDescription": "This property shall contain the desired liquid flow rate, in liters per minute… 200 "description": "The liquid flow (L/min).", 202 …"longDescription": "This property shall contain the liquid flow rate, in liters per minute units, … 247 "description": "The rated liquid flow (L/min) for this loop interface.", 248 …"longDescription": "This property shall contain the rated liquid flow, in liters per minute units,… 258 "description": "The pressure (kPa) at which the rated liquid flow is valid.", 259 …property shall contain the pressure, in kilopascal units, that the rated liquid flow is valid for …
|
H A D | PhysicalContext.json | 99 "CoolingSubsystem": "The entire cooling, or air and liquid, subsystem.", 111 "LiquidInlet": "The liquid inlet point of the chassis.", 112 "LiquidOutlet": "The liquid outlet point of the chassis.",
|
H A D | Pump.v1_2_0.json | 332 "Liquid", 337 "Liquid": "A water or liquid pump." string
|
H A D | Thermal.v1_7_3.json | 386 …mental conditions present. For example, liquid inlet temperature can be adjusted based on the ava… 397 …mental conditions present. For example, liquid inlet temperature can be adjusted based on the ava…
|
H A D | Sensor.v1_10_1.json | 178 "LiquidFlow": "Liquid flow (L/s).", 179 "LiquidFlowLPM": "Liquid flow (L/min).", 180 "LiquidLevel": "Liquid level (cm).", 204 …"LiquidFlow": "This value shall indicate a measurement of a volume of liquid per unit of time, in … 205 …"LiquidFlowLPM": "This value shall indicate a measurement of a volume of liquid per unit of time, … 349 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava… 358 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava…
|
H A D | CoolingLoop.v1_0_3.json | 301 "description": "The rated liquid flow (L/min) for this cooling loop.", 302 …"longDescription": "This property shall contain the rated liquid flow, in liters per minute units,…
|
H A D | LeakDetection.v1_1_0.json | 36 … "The `LeakDetection` schema contains definitions for reporting leaks in liquid cooling systems or…
|
/openbmc/bmcweb/redfish-core/schema/dmtf/csdl/ |
H A D | CoolantConnector_v1.xml | 54 …rm="OData.Description" String="The `CoolantConnector` schema describes a liquid coolant connector,… 108 …<Annotation Term="OData.Description" String="The rated liquid flow (L/min) for this loop interface… 109 …rm="OData.LongDescription" String="This property shall contain the rated liquid flow, in liters pe… 115 …<Annotation Term="OData.Description" String="The pressure (kPa) at which the rated liquid flow is … 116 …property shall contain the pressure, in kilopascal units, that the rated liquid flow is valid for … 152 <Annotation Term="OData.Description" String="The liquid flow (L/min)."/> 153 …<Annotation Term="OData.LongDescription" String="This property shall contain the liquid flow rate,… 279 <Annotation Term="OData.Description" String="The desired liquid flow rate (L/min)."/> 280 …="OData.LongDescription" String="This property shall contain the desired liquid flow rate, in lite…
|
H A D | PhysicalContext_v1.xml | 39 <Annotation Term="OData.Description" String="The liquid inlet point of the chassis."/> 50 <Annotation Term="OData.Description" String="The liquid outlet point of the chassis."/> 261 … <Annotation Term="OData.Description" String="The entire cooling, or air and liquid, subsystem."/>
|
H A D | Sensor_v1.xml | 253 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava… 258 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava… 570 <Annotation Term="OData.Description" String="Liquid level (cm)."/> 603 <Annotation Term="OData.Description" String="Liquid flow (L/s)."/> 604 …cription" String="This value shall indicate a measurement of a volume of liquid per unit of time, … 616 <Annotation Term="OData.Description" String="Liquid flow (L/min)."/> 617 …cription" String="This value shall indicate a measurement of a volume of liquid per unit of time, …
|
/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema-installed/ |
H A D | PhysicalContext.json | 99 "CoolingSubsystem": "The entire cooling, or air and liquid, subsystem.", 111 "LiquidInlet": "The liquid inlet point of the chassis.", 112 "LiquidOutlet": "The liquid outlet point of the chassis.",
|
H A D | Thermal.v1_7_3.json | 386 …mental conditions present. For example, liquid inlet temperature can be adjusted based on the ava… 397 …mental conditions present. For example, liquid inlet temperature can be adjusted based on the ava…
|
H A D | Sensor.v1_10_1.json | 178 "LiquidFlow": "Liquid flow (L/s).", 179 "LiquidFlowLPM": "Liquid flow (L/min).", 180 "LiquidLevel": "Liquid level (cm).", 204 …"LiquidFlow": "This value shall indicate a measurement of a volume of liquid per unit of time, in … 205 …"LiquidFlowLPM": "This value shall indicate a measurement of a volume of liquid per unit of time, … 349 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava… 358 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava…
|
/openbmc/linux/Documentation/devicetree/bindings/display/panel/ |
H A D | lg,lg4573.yaml | 7 title: LG LG4573 TFT Liquid Crystal Display with SPI control bus
|
/openbmc/linux/Documentation/admin-guide/auxdisplay/ |
H A D | ks0108.rst | 32 :Type: LCD Controller (Liquid Crystal Display Controller)
|
H A D | cfag12864b.rst | 32 :Type: LCD (Liquid Crystal Display)
|
/openbmc/linux/Documentation/hwmon/ |
H A D | nzxt-kraken2.rst | 19 all-in-one CPU liquid coolers. Three sensors are available: fan speed, pump
|
H A D | aquacomputer_d5next.rst | 59 and an estimation of the dissipated/absorbed power in the liquid cooling loop.
|
/openbmc/phosphor-dbus-interfaces/yaml/xyz/openbmc_project/Sensor/ |
H A D | Value.interface.yaml | 73 To calculate the liquid flow in Liters Per Minute.
|
/openbmc/bmcweb/redfish-core/schema/dmtf/installed/ |
H A D | PhysicalContext_v1.xml | 39 <Annotation Term="OData.Description" String="The liquid inlet point of the chassis."/> 50 <Annotation Term="OData.Description" String="The liquid outlet point of the chassis."/> 261 … <Annotation Term="OData.Description" String="The entire cooling, or air and liquid, subsystem."/>
|
H A D | Sensor_v1.xml | 253 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava… 258 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava… 570 <Annotation Term="OData.Description" String="Liquid level (cm)."/> 603 <Annotation Term="OData.Description" String="Liquid flow (L/s)."/> 604 …cription" String="This value shall indicate a measurement of a volume of liquid per unit of time, … 616 <Annotation Term="OData.Description" String="Liquid flow (L/min)."/> 617 …cription" String="This value shall indicate a measurement of a volume of liquid per unit of time, …
|
/openbmc/linux/drivers/gpu/drm/amd/pm/powerplay/hwmgr/ |
H A D | pptable_v1_0.h | 412 UCHAR ucLiquid1_I2C_address; /*Liquid */ 443 UCHAR ucLiquid1_I2C_address; //Liquid
|
/openbmc/linux/sound/firewire/ |
H A D | Kconfig | 27 * Focusrite Liquid Saffire 56
|
/openbmc/linux/arch/arm/mach-sa1100/include/mach/ |
H A D | SA-1100.h | 1566 * Liquid Crystal Display (LCD) control registers 1569 * LCCR0 Liquid Crystal Display (LCD) Control Register 0 1574 * LCSR Liquid Crystal Display (LCD) Status Register 1580 * DBAR1 Liquid Crystal Display (LCD) Direct Memory Access 1582 * DCAR1 Liquid Crystal Display (LCD) Direct Memory Access 1584 * DBAR2 Liquid Crystal Display (LCD) Direct Memory Access 1586 * DCAR2 Liquid Crystal Display (LCD) Direct Memory Access 1588 * LCCR1 Liquid Crystal Display (LCD) Control Register 1 1594 * LCCR2 Liquid Crystal Display (LCD) Control Register 2 1600 * LCCR3 Liquid Crystal Display (LCD) Control Register 3
|