8132399c |
| 27-Feb-2024 |
Ed Tanous <ed@tanous.net> |
Reformat files with new linter
All changes should be whitespace, and were done using npm run-script lint.
Change-Id: I943c6b435c5c872841af5affc1e89910468b5ca6 Signed-off-by: Ed Tanous <ed@tanous.ne
Reformat files with new linter
All changes should be whitespace, and were done using npm run-script lint.
Change-Id: I943c6b435c5c872841af5affc1e89910468b5ca6 Signed-off-by: Ed Tanous <ed@tanous.net>
show more ...
|
#
710f121e |
| 08-Oct-2023 |
HuyLe <hule@amperecomputing.com> |
Fix pressing Refresh button not removing deleted sensors
Issue: when clicking the Refresh button at top right corner of the WebUI, sensors that were removed from Redfish are not removed from the Web
Fix pressing Refresh button not removing deleted sensors
Issue: when clicking the Refresh button at top right corner of the WebUI, sensors that were removed from Redfish are not removed from the WebUI but still shown with old sensor values. Root cause: current code keeps a list of sensors. Click on Refresh button just checks and updates sensors returned by Redfish, it does not check if sensors are still present or not. This is incorrect for sensors on hot plug devices or PLDM sensors when the sensor source is not available. In this case, sensors are completely removed instead of just their values changed to n/a. Solution: Initialize an empty array sensor state to retrieve existing sensor data whenever loading sensors.
Change-Id: Ifb0c0586fdba22b6f446c58b3d5b937a3f3ee750 Signed-off-by: HuyLe <hule@amperecomputing.com>
show more ...
|
#
9298ea3f |
| 11-Jan-2023 |
kirankumarb07 <kirankumarb@ami.com> |
Fixed sensor mismatch issue with IPMI and redfish
Description: The sensor count in WebUI is mismatched when compared to IPMI and REDFISH responses. When Web UI is iterating the sensor response prope
Fixed sensor mismatch issue with IPMI and redfish
Description: The sensor count in WebUI is mismatched when compared to IPMI and REDFISH responses. When Web UI is iterating the sensor response property, the iteration is stopped when the key value is undefined. As a result, the sensor details in the web UI are incorrect. So added the code changes to check the property value in every iteration, whether the value is present or not.
Tested: Step 1: Login to WEB UI Step 2: Navigate to Hardware Status and Sensors Step 3: Check the sensor details with IPMI and redfish response Step 4: All the sensors and those details in the IPMI and redfish response are listing in Web UI
Change-Id: Icf5098b3dd2413851e755d9ede17a8501cbb7411 Signed-off-by: Kirankumar Ballapalli <kirankumarb@ami.com>
show more ...
|
#
946535f3 |
| 24-Oct-2022 |
wangqi02 <wangqi02@inspur.com> |
Fix In-page "Refresh" button doesn't update sensor readings
The reason for this problem is uniqBy always keep the first one when removing repetition
Resolves: https://github.com/openbmc/webui-vue/i
Fix In-page "Refresh" button doesn't update sensor readings
The reason for this problem is uniqBy always keep the first one when removing repetition
Resolves: https://github.com/openbmc/webui-vue/issues/60
Change-Id: Iec87d7845e694b0f2a14de4061ae113eac492fc0 Signed-off-by: wangqi02 <wangqi02@inspur.com>
show more ...
|
#
a69102a2 |
| 02-Aug-2021 |
Konstantin Aladyshev <aladyshev22@gmail.com> |
Use a 'V' symbol for voltage unit
Currently webui-vue displays all sensor data with units written as symbols ('A', 'W', 'C', 'RPM') except for voltage which is written as 'Volts'. Use a 'V' symbol f
Use a 'V' symbol for voltage unit
Currently webui-vue displays all sensor data with units written as symbols ('A', 'W', 'C', 'RPM') except for voltage which is written as 'Volts'. Use a 'V' symbol for voltage unit for unification.
Change-Id: I257b6d6bf1d099f62a861430a6448368b56dace1 Signed-off-by: Konstantin Aladyshev <aladyshev22@gmail.com>
show more ...
|
#
7affc529 |
| 06-Jul-2021 |
Sandeepa Singh <sandeepa.singh@ibm.com> |
IA update: Update health section
This is the second update to information architecture changes and has the following changes:
- Health section is updated to hardware status section - Hardware statu
IA update: Update health section
This is the second update to information architecture changes and has the following changes:
- Health section is updated to hardware status section - Hardware status page is updated to inventory and LEDs page - Route for sensors page has been updated
Signed-off-by: Sandeepa Singh <sandeepa.singh@ibm.com> Change-Id: Ia1ba3a15a243a00f59a2ec646132436eb355a999
show more ...
|