History log of /openbmc/webui-vue/src/store/modules/HardwareStatus/SensorsStore.js (Results 1 – 6 of 6)
Revision Date Author Comments
# 8132399c 27-Feb-2024 Ed Tanous <ed@tanous.net>

Reformat files with new linter

All changes should be whitespace, and were done using npm run-script
lint.

Change-Id: I943c6b435c5c872841af5affc1e89910468b5ca6
Signed-off-by: Ed Tanous <ed@tanous.ne

Reformat files with new linter

All changes should be whitespace, and were done using npm run-script
lint.

Change-Id: I943c6b435c5c872841af5affc1e89910468b5ca6
Signed-off-by: Ed Tanous <ed@tanous.net>

show more ...


# 710f121e 08-Oct-2023 HuyLe <hule@amperecomputing.com>

Fix pressing Refresh button not removing deleted sensors

Issue: when clicking the Refresh button at top right corner of the
WebUI, sensors that were removed from Redfish are not removed from the
Web

Fix pressing Refresh button not removing deleted sensors

Issue: when clicking the Refresh button at top right corner of the
WebUI, sensors that were removed from Redfish are not removed from the
WebUI but still shown with old sensor values.
Root cause: current code keeps a list of sensors. Click on Refresh
button just checks and updates sensors returned by Redfish, it does not
check if sensors are still present or not. This is incorrect for
sensors on hot plug devices or PLDM sensors when the sensor source is
not available. In this case, sensors are completely removed instead of
just their values changed to n/a.
Solution: Initialize an empty array sensor state to retrieve
existing sensor data whenever loading sensors.

Change-Id: Ifb0c0586fdba22b6f446c58b3d5b937a3f3ee750
Signed-off-by: HuyLe <hule@amperecomputing.com>

show more ...


# 9298ea3f 11-Jan-2023 kirankumarb07 <kirankumarb@ami.com>

Fixed sensor mismatch issue with IPMI and redfish

Description:
The sensor count in WebUI is mismatched when compared to
IPMI and REDFISH responses. When Web UI is iterating the
sensor response prope

Fixed sensor mismatch issue with IPMI and redfish

Description:
The sensor count in WebUI is mismatched when compared to
IPMI and REDFISH responses. When Web UI is iterating the
sensor response property, the iteration is stopped when
the key value is undefined. As a result, the sensor details
in the web UI are incorrect. So added the code changes to
check the property value in every iteration, whether the
value is present or not.

Tested:
Step 1: Login to WEB UI
Step 2: Navigate to Hardware Status and Sensors
Step 3: Check the sensor details with IPMI and redfish response
Step 4: All the sensors and those details in the IPMI and redfish
response are listing in Web UI

Change-Id: Icf5098b3dd2413851e755d9ede17a8501cbb7411
Signed-off-by: Kirankumar Ballapalli <kirankumarb@ami.com>

show more ...


# 946535f3 24-Oct-2022 wangqi02 <wangqi02@inspur.com>

Fix In-page "Refresh" button doesn't update sensor readings

The reason for this problem is uniqBy always keep the first one when removing repetition

Resolves: https://github.com/openbmc/webui-vue/i

Fix In-page "Refresh" button doesn't update sensor readings

The reason for this problem is uniqBy always keep the first one when removing repetition

Resolves: https://github.com/openbmc/webui-vue/issues/60

Change-Id: Iec87d7845e694b0f2a14de4061ae113eac492fc0
Signed-off-by: wangqi02 <wangqi02@inspur.com>

show more ...


# a69102a2 02-Aug-2021 Konstantin Aladyshev <aladyshev22@gmail.com>

Use a 'V' symbol for voltage unit

Currently webui-vue displays all sensor data with units written as
symbols ('A', 'W', 'C', 'RPM') except for voltage which is written as
'Volts'.
Use a 'V' symbol f

Use a 'V' symbol for voltage unit

Currently webui-vue displays all sensor data with units written as
symbols ('A', 'W', 'C', 'RPM') except for voltage which is written as
'Volts'.
Use a 'V' symbol for voltage unit for unification.

Change-Id: I257b6d6bf1d099f62a861430a6448368b56dace1
Signed-off-by: Konstantin Aladyshev <aladyshev22@gmail.com>

show more ...


# 7affc529 06-Jul-2021 Sandeepa Singh <sandeepa.singh@ibm.com>

IA update: Update health section

This is the second update to information architecture changes and
has the following changes:

- Health section is updated to hardware status section
- Hardware statu

IA update: Update health section

This is the second update to information architecture changes and
has the following changes:

- Health section is updated to hardware status section
- Hardware status page is updated to inventory and LEDs page
- Route for sensors page has been updated

Signed-off-by: Sandeepa Singh <sandeepa.singh@ibm.com>
Change-Id: Ia1ba3a15a243a00f59a2ec646132436eb355a999

show more ...