Home
last modified time | relevance | path

Searched hist:e3b6582e (Results 1 – 4 of 4) sorted by relevance

/openbmc/entity-manager/configurations/
H A Dgenesis3_psu.jsone3b6582e Wed Nov 02 04:29:38 CDT 2022 Naresh Solanki <Naresh.Solanki@9elements.com> configurations: Add IBM genesis3 board configuration

Add configuration for various VRs & Fan used in Genesis3 Board.
Also configure PID for fan control.

Tested: Tested on Genesis3.
- All sensors are running
- 4 PSU are exposed in the inventory
- 24 Fans are exposed in the inventory
- Fan PID runs an keeps the PSU cool

Signed-off-by: Naresh Solanki <Naresh.Solanki@9elements.com>
Change-Id: I1e54ca0e103217780dff435ae69c138f16d9d419
H A Dgenesis3_chassis.jsone3b6582e Wed Nov 02 04:29:38 CDT 2022 Naresh Solanki <Naresh.Solanki@9elements.com> configurations: Add IBM genesis3 board configuration

Add configuration for various VRs & Fan used in Genesis3 Board.
Also configure PID for fan control.

Tested: Tested on Genesis3.
- All sensors are running
- 4 PSU are exposed in the inventory
- 24 Fans are exposed in the inventory
- Fan PID runs an keeps the PSU cool

Signed-off-by: Naresh Solanki <Naresh.Solanki@9elements.com>
Change-Id: I1e54ca0e103217780dff435ae69c138f16d9d419
H A Dgenesis3_baseboard.jsone3b6582e Wed Nov 02 04:29:38 CDT 2022 Naresh Solanki <Naresh.Solanki@9elements.com> configurations: Add IBM genesis3 board configuration

Add configuration for various VRs & Fan used in Genesis3 Board.
Also configure PID for fan control.

Tested: Tested on Genesis3.
- All sensors are running
- 4 PSU are exposed in the inventory
- 24 Fans are exposed in the inventory
- Fan PID runs an keeps the PSU cool

Signed-off-by: Naresh Solanki <Naresh.Solanki@9elements.com>
Change-Id: I1e54ca0e103217780dff435ae69c138f16d9d419
/openbmc/entity-manager/
H A Dmeson.builde3b6582e Wed Nov 02 04:29:38 CDT 2022 Naresh Solanki <Naresh.Solanki@9elements.com> configurations: Add IBM genesis3 board configuration

Add configuration for various VRs & Fan used in Genesis3 Board.
Also configure PID for fan control.

Tested: Tested on Genesis3.
- All sensors are running
- 4 PSU are exposed in the inventory
- 24 Fans are exposed in the inventory
- Fan PID runs an keeps the PSU cool

Signed-off-by: Naresh Solanki <Naresh.Solanki@9elements.com>