Searched hist:"6710 ba2c" (Results 1 – 6 of 6) sorted by relevance
/openbmc/phosphor-power/phosphor-power-supply/test/ |
H A D | mock.hpp | 6710ba2c Wed Oct 27 12:39:31 CDT 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add code to detect VOUT_OV_FAULT If the output voltage hits an overvoltage condition, the VOUT_OV_FAULT bit (bit 5 of STATUS_WORD low byte) should turn on. The PMBus spec indicates that VOUT fault/warning (bit 7 high byte) and VOUT_OV_FAULT are associated with status in the STATUS_VOUT command response. Check for VOUT_OV_FAULT after check for VIN_UV_FAULT, create error if the fault is indicated. Change-Id: Ia68b4f986393f0ba0184401deb29b4f5d25a2ed0 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|
H A D | power_supply_tests.cpp | 6710ba2c Wed Oct 27 12:39:31 CDT 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add code to detect VOUT_OV_FAULT If the output voltage hits an overvoltage condition, the VOUT_OV_FAULT bit (bit 5 of STATUS_WORD low byte) should turn on. The PMBus spec indicates that VOUT fault/warning (bit 7 high byte) and VOUT_OV_FAULT are associated with status in the STATUS_VOUT command response. Check for VOUT_OV_FAULT after check for VIN_UV_FAULT, create error if the fault is indicated. Change-Id: Ia68b4f986393f0ba0184401deb29b4f5d25a2ed0 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|
/openbmc/phosphor-power/ |
H A D | pmbus.hpp | 6710ba2c Wed Oct 27 12:39:31 CDT 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add code to detect VOUT_OV_FAULT If the output voltage hits an overvoltage condition, the VOUT_OV_FAULT bit (bit 5 of STATUS_WORD low byte) should turn on. The PMBus spec indicates that VOUT fault/warning (bit 7 high byte) and VOUT_OV_FAULT are associated with status in the STATUS_VOUT command response. Check for VOUT_OV_FAULT after check for VIN_UV_FAULT, create error if the fault is indicated. Change-Id: Ia68b4f986393f0ba0184401deb29b4f5d25a2ed0 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|
/openbmc/phosphor-power/phosphor-power-supply/ |
H A D | power_supply.hpp | 6710ba2c Wed Oct 27 12:39:31 CDT 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add code to detect VOUT_OV_FAULT If the output voltage hits an overvoltage condition, the VOUT_OV_FAULT bit (bit 5 of STATUS_WORD low byte) should turn on. The PMBus spec indicates that VOUT fault/warning (bit 7 high byte) and VOUT_OV_FAULT are associated with status in the STATUS_VOUT command response. Check for VOUT_OV_FAULT after check for VIN_UV_FAULT, create error if the fault is indicated. Change-Id: Ia68b4f986393f0ba0184401deb29b4f5d25a2ed0 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|
H A D | power_supply.cpp | 6710ba2c Wed Oct 27 12:39:31 CDT 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add code to detect VOUT_OV_FAULT If the output voltage hits an overvoltage condition, the VOUT_OV_FAULT bit (bit 5 of STATUS_WORD low byte) should turn on. The PMBus spec indicates that VOUT fault/warning (bit 7 high byte) and VOUT_OV_FAULT are associated with status in the STATUS_VOUT command response. Check for VOUT_OV_FAULT after check for VIN_UV_FAULT, create error if the fault is indicated. Change-Id: Ia68b4f986393f0ba0184401deb29b4f5d25a2ed0 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|
H A D | psu_manager.cpp | 6710ba2c Wed Oct 27 12:39:31 CDT 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add code to detect VOUT_OV_FAULT If the output voltage hits an overvoltage condition, the VOUT_OV_FAULT bit (bit 5 of STATUS_WORD low byte) should turn on. The PMBus spec indicates that VOUT fault/warning (bit 7 high byte) and VOUT_OV_FAULT are associated with status in the STATUS_VOUT command response. Check for VOUT_OV_FAULT after check for VIN_UV_FAULT, create error if the fault is indicated. Change-Id: Ia68b4f986393f0ba0184401deb29b4f5d25a2ed0 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|