Home
last modified time | relevance | path

Searched hist:"27 d95006" (Results 1 – 1 of 1) sorted by relevance

/openbmc/entity-manager/configurations/
H A Dharma_fanboard.json27d95006 Sun May 12 21:07:34 CDT 2024 Daniel Hsu <Daniel-Hsu@quantatw.com> configurations: harma: remove fan power sensors

remove fan power sensors and update fan threshold.

1. FAN CPLD does not implement FAN power_W monitor feature due to
CPLD cell count limitation.
2. BMC can get FAN voltage(V) and current(A)
3. The FAN Power(W) is not default feature.

Testing:
root@bmc:~# curl -k -u root:0penBmc -X GET https://localhost/.../
{
"@odata.id": "/...",
"@odata.type": "#SensorCollection.SensorCollection",
"Description": "Collection of Sensors for this Chassis",
"Members": [
{
"@odata.id": "/.../current_FAN_BP0_FAN0_CURR_A"
},
{
"@odata.id": "/.../current_FAN_BP0_FAN1_CURR_A"
},
{
"@odata.id": "/.../current_FAN_BP0_FAN2_CURR_A"
},
{
"@odata.id": "/.../current_FAN_BP0_FAN3_CURR_A"
},
{
"@odata.id": "/.../fanpwm_FAN_BP0_FAN_PWM"
},
{
"@odata.id": "/.../fantach_FAN_BP0_FAN0_TACH_IL_SPEED_RPM"
},
{
"@odata.id": "/.../fantach_FAN_BP0_FAN0_TACH_OL_SPEED_RPM"
},
{
"@odata.id": "/.../fantach_FAN_BP0_FAN1_TACH_IL_SPEED_RPM"
},
{
"@odata.id": "/.../fantach_FAN_BP0_FAN1_TACH_OL_SPEED_RPM"
},
{
"@odata.id": "/.../fantach_FAN_BP0_FAN2_TACH_IL_SPEED_RPM"
},
{
"@odata.id": "/.../fantach_FAN_BP0_FAN2_TACH_OL_SPEED_RPM"
},
{
"@odata.id": "/.../fantach_FAN_BP0_FAN3_TACH_IL_SPEED_RPM"
},
{
"@odata.id": "/.../fantach_FAN_BP0_FAN3_TACH_OL_SPEED_RPM"
},
{
"@odata.id": "/.../voltage_FAN_BP0_FAN0_VOLT_V"
},
{
"@odata.id": "/.../voltage_FAN_BP0_FAN1_VOLT_V"
},
{
"@odata.id": "/.../voltage_FAN_BP0_FAN2_VOLT_V"
},
{
"@odata.id": "/.../voltage_FAN_BP0_FAN3_VOLT_V"
}
],
"Members@odata.count": 17,
"Name": "Sensors"
}

Change-Id: Icd3ff037960bc641381c6383a76979863c3396c7
Signed-off-by: Daniel Hsu <Daniel-Hsu@quantatw.com>