1*** Settings ***
2
3Documentation          Module to test IPMI network functionality.
4Resource               ../lib/ipmi_client.robot
5Resource               ../lib/openbmc_ffdc.robot
6Resource               ../lib/bmc_network_utils.robot
7Resource               ../lib/boot_utils.robot
8Library                ../lib/ipmi_utils.py
9Library                ../lib/gen_robot_valid.py
10Library                ../lib/var_funcs.py
11Library                ../lib/bmc_network_utils.py
12Variables              ../data/ipmi_raw_cmd_table.py
13
14Suite Setup            Suite Setup Execution
15Suite Teardown         Redfish.Logout
16Test Setup             Printn
17Test Teardown          Test Teardown Execution
18
19Test Tags             IPMI_Network_Configuration
20
21*** Variables ***
22
23${vlan_id_for_ipmi}     ${10}
24@{vlan_ids}             ${20}  ${30}
25${interface}            eth0
26${initial_lan_config}   &{EMPTY}
27${vlan_resource}        ${NETWORK_MANAGER}action/VLAN
28${subnet_mask}          ${24}
29${gateway_ip}           0.0.0.0
30${vlan_id_for_rest}     ${30}
31
32
33*** Test Cases ***
34
35Verify IPMI Inband Network Configuration
36    [Documentation]  Verify BMC network configuration via inband IPMI.
37    [Tags]  Verify_IPMI_Inband_Network_Configuration
38    [Teardown]  Run Keywords  Restore Configuration  AND  set_base_url    https://${OPENBMC_HOST}:${HTTPS_PORT}
39    ...  AND  FFDC On Test Case Fail  AND
40    ...  Redfish.Login  AND  Run IPMI Command  ${IPMI_RAW_CMD['Device ID']['Get'][0]}
41
42    Redfish Power On
43
44    Set IPMI Inband Network Configuration  ${STATIC_IP}  ${NETMASK}  ${GATEWAY}
45    Sleep  10
46
47    ${lan_print_output}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
48    Valid Value  lan_print_output['IP Address']  ["${STATIC_IP}"]
49    Valid Value  lan_print_output['Subnet Mask']  ["${NETMASK}"]
50    Valid Value  lan_print_output['Default Gateway IP']  ["${GATEWAY}"]
51
52    # To verify changed static ip is communicable through external IPMI cmd.
53    Run External IPMI Raw Command  ${IPMI_RAW_CMD['Device ID']['Get'][0]}  H=${STATIC_IP}
54
55    set_base_url    https://${STATIC_IP}:${HTTPS_PORT}
56    Redfish.Login
57
58
59    ${ipv4_addresses}=  Redfish.Get Attribute
60    ...  ${REDFISH_NW_ETH_IFACE}${interface}  IPv4Addresses
61
62    FOR  ${ipv4_address}  IN  @{ipv4_addresses}
63        ${ip_address}=  Set Variable if  '${ipv4_address['Address']}' == '${STATIC_IP}'
64                        ...  ${ipv4_address}
65        Exit For Loop If  ${ip_address} != None
66    END
67
68    Should Be Equal  ${ip_address['AddressOrigin']}  Static
69    Should Be Equal  ${ip_address['SubnetMask']}  ${NETMASK}
70    Should Be Equal  ${ip_address['Gateway']}  ${GATEWAY}
71
72    Redfish.Logout
73
74
75Disable VLAN Via IPMI When Multiple VLAN Exist On BMC
76    [Documentation]  Disable  VLAN Via IPMI When Multiple VLAN Exist On BMC.
77    [Tags]   Disable_VLAN_Via_IPMI_When_Multiple_VLAN_Exist_On_BMC
78
79    FOR  ${vlan_id}  IN  @{vlan_ids}
80      Create VLAN  ${vlan_id}
81    END
82
83    Create VLAN Via IPMI  off
84
85    ${lan_config}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
86    Valid Value  lan_config['802.1q VLAN ID']  ['Disabled']
87
88
89Configure IP On VLAN Via IPMI
90    [Documentation]   Configure IP On VLAN Via IPMI.
91    [Tags]  Configure_IP_On_VLAN_Via_IPMI
92
93    Create VLAN Via IPMI  ${vlan_id_for_ipmi}
94
95    Run Inband IPMI Standard Command
96    ...  lan set ${CHANNEL_NUMBER} ipaddr ${STATIC_IP}  login_host=${0}
97
98    ${lan_config}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
99    Valid Value  lan_config['802.1q VLAN ID']  ['${vlan_id_for_ipmi}']
100    Valid Value  lan_config['IP Address']  ["${STATIC_IP}"]
101
102
103Create VLAN Via IPMI When LAN And VLAN Exist On BMC
104    [Documentation]  Create VLAN Via IPMI When LAN And VLAN Exist On BMC.
105    [Tags]   Create_VLAN_Via_IPMI_When_LAN_And_VLAN_Exist_On_BMC
106    [Setup]  Create VLAN  ${vlan_id_for_rest}
107
108    Create VLAN Via IPMI  ${vlan_id_for_ipmi}
109
110    ${lan_config}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
111    Valid Value  lan_config['802.1q VLAN ID']  ['${vlan_id_for_ipmi}']
112
113
114Create VLAN Via IPMI And Verify
115    [Documentation]  Create and verify VLAN via IPMI.
116    [Tags]  Create_VLAN_Via_IPMI_And_Verify
117
118    Create VLAN Via IPMI  ${vlan_id_for_ipmi}
119
120    ${lan_config}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
121    Valid Value  lan_config['802.1q VLAN ID']  ['${vlan_id_for_ipmi}']
122    Valid Value  lan_config['IP Address']  ['${ip_address}']
123    Valid Value  lan_config['Subnet Mask']  ['${subnet_mask}']
124
125Test Disabling Of VLAN Via IPMI
126    [Documentation]  Disable VLAN and verify via IPMI.
127    [Tags]  Test_Disabling_Of_VLAN_Via_IPMI
128
129    Create VLAN Via IPMI  ${vlan_id_for_ipmi}
130    Create VLAN Via IPMI  off
131
132    ${lan_config}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
133    Valid Value  lan_config['802.1q VLAN ID']  ['Disabled']
134
135
136Create VLAN When LAN And VLAN Exist With IP Address Configured
137   [Documentation]  Create VLAN when LAN and VLAN exist with IP address configured.
138   [Tags]  Create_VLAN_When_LAN_And_VLAN_Exist_With_IP_Address_Configured
139   [Setup]  Run Keywords  Create VLAN  ${vlan_id_for_rest}  interface=${interface}
140   ...  AND  Configure Network Settings On VLAN  ${vlan_id_for_rest}  ${STATIC_IP}
141   ...  ${netmask}  ${gateway}  interface=${interface}
142
143   Create VLAN Via IPMI   ${vlan_id_for_ipmi}
144
145   ${lan_config}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
146   Valid Value  lan_config['802.1q VLAN ID']  ['${vlan_id_for_ipmi}']
147   Valid Value  lan_config['IP Address']  ['${STATIC_IP}']
148
149
150Create Multiple VLANs Via IPMI And Verify
151    [Documentation]  Create multiple VLANs through IPMI.
152    [Tags]    Create_Multiple_VLANs_Via_IPMI_And_Verify
153
154    FOR  ${vlan_id}  IN  @{vlan_ids}
155
156      Create VLAN Via IPMI  ${vlan_id}
157
158      ${lan_config}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
159
160      # Validate VLAN creation.
161      Valid Value  lan_config['802.1q VLAN ID']  ['${vlan_id}']
162
163      # Validate existing IP address.
164      Valid Value  lan_config['IP Address']  ['${ip_address}']
165
166      # Validate existing subnet mask.
167      Valid Value  lan_config['Subnet Mask']  ['${subnet_mask}']
168    END
169
170
171*** Keywords ***
172
173Create VLAN Via IPMI
174    [Documentation]  Create VLAN via inband IPMI command.
175    [Arguments]  ${vlan_id}  ${channel_number}=${CHANNEL_NUMBER}
176
177    # Description of argument(s):
178    # vlan_id  The VLAN ID (e.g. '10').
179
180    Run Inband IPMI Standard Command
181    ...  lan set ${channel_number} vlan id ${vlan_id}  login_host=${0}
182
183
184Set IPMI Inband Network Configuration
185    [Documentation]  Run sequence of standard IPMI command in-band and set
186    ...              the IP configuration.
187    [Arguments]  ${ip}  ${netmask}  ${gateway}  ${login}=${1}
188
189    # Description of argument(s):
190    # ip       The IP address to be set using ipmitool-inband.
191    # netmask  The Netmask to be set using ipmitool-inband.
192    # gateway  The Gateway address to be set using ipmitool-inband.
193
194    Run Inband IPMI Standard Command
195    ...  lan set ${CHANNEL_NUMBER} ipsrc static  login_host=${login}
196    Run Inband IPMI Standard Command
197    ...  lan set ${CHANNEL_NUMBER} ipaddr ${ip}  login_host=${0}
198    Run Inband IPMI Standard Command
199    ...  lan set ${CHANNEL_NUMBER} netmask ${netmask}  login_host=${0}
200    Run Inband IPMI Standard Command
201    ...  lan set ${CHANNEL_NUMBER} defgw ipaddr ${gateway}  login_host=${0}
202
203
204Restore Configuration
205    [Documentation]  Restore the configuration to its pre-test state.
206
207    ${length}=  Get Length  ${initial_lan_config}
208    Return From Keyword If  ${length} == ${0}
209
210    Set IPMI Inband Network Configuration  ${ip_address}  ${subnet_mask}
211    ...  ${initial_lan_config['Default Gateway IP']}  login=${0}
212
213
214Suite Setup Execution
215    [Documentation]  Suite Setup Execution.
216
217    Redfish.Login
218
219    ${initial_lan_config}=  Get LAN Print Dict  ${CHANNEL_NUMBER}  ipmi_cmd_type=inband
220    Set Suite Variable  ${initial_lan_config}
221
222    Run Inband IPMI Standard Command
223    ...  lan set ${CHANNEL_NUMBER} ipsrc static  login_host=${1}
224
225    ${host_name}  ${ip_address}=  Get Host Name IP  host=${OPENBMC_HOST}
226    Set Suite Variable  ${ip_address}
227
228    @{network_configurations}=  Get Network Configuration
229    FOR  ${network_configuration}  IN  @{network_configurations}
230       Run Keyword If  '${network_configuration['Address']}' == '${ip_address}'
231       ...  Run Keywords  Set Suite Variable  ${subnet_mask}   ${network_configuration['SubnetMask']}  AND
232       ...  Exit For Loop
233    END
234
235Test Teardown Execution
236   [Documentation]  Test Teardown Execution.
237
238   FFDC On Test Case Fail
239   Create VLAN Via IPMI  off
240   Restore Configuration
241