/openbmc/linux/Documentation/devicetree/bindings/rtc/ |
H A D | dallas,ds1390.txt | 11 - trickle-diode-disable : Do not use internal trickle charger diode 12 Should be given if internal trickle charger diode should be disabled
|
H A D | rtc-ds1307.yaml | 78 trickle-diode-disable: 79 description: Do not use internal trickle charger diode. Should be given if internal 80 trickle charger diode should be disabled (superseded by aux-voltage-chargeable)
|
H A D | epson,rx8900.yaml | 30 trickle-diode-disable: true 48 trickle-diode-disable;
|
H A D | rtc.yaml | 41 trickle-diode-disable: 44 Do not use internal trickle charger diode. Should be given if 45 internal trickle charger diode should be disabled.
|
H A D | ti,bq32000.yaml | 30 trickle-diode-disable: true
|
H A D | abracon,abx80x.txt | 29 - "abracon,tc-diode": should be "standard" (0.6V) or "schottky" (0.3V)
|
/openbmc/linux/Documentation/hwmon/ |
H A D | max6639.rst | 23 temperature and one external diode-connected transistor or two external 24 diode-connected transistors. 33 temp1_fault R Temperature channel 1 diode fault 34 temp2_fault R Temperature channel 2 diode fault
|
H A D | max6697.rst | 75 remote temperature sensors. Remote temperature sensors are diode-connected 76 thermal transistors, except for MAX6698 which supports three diode-connected 90 tempX_fault RO temperature diode fault (remote sensors only)
|
H A D | max31730.rst | 23 temperatures of three external diode-connected transistors. The operating 26 diode, while beta compensation corrects for temperature-measurement
|
H A D | smsc47m192.rst | 85 temp1_input chip temperature measured by on-chip diode 87 would typically be wired to the diode inside the CPU) 105 temp[2-3]_input_fault diode fault flags for temperature inputs 2 and 3. 108 to ground or Vcc. '1' indicates a diode fault.
|
H A D | max6642.rst | 24 well as the temperature on one external diode.
|
H A D | thmc50.rst | 45 external diode-type temperature sensor (compatible w/ the diode sensor inside
|
H A D | max31760.rst | 23 temperature of a discrete diode-connected transistor, such as a 2N3906, 24 or a thermal diode commonly found on CPUs, graphics processor units (GPUs),
|
H A D | max1619.rst | 24 well as the temperature of up to one external diode.
|
H A D | vt1211.rst | 68 Reading 1 temp1 Intel thermal diode 69 Reading 3 temp2 Internal thermal diode 126 internal thermal diode and the driver does all the scaling for temp2 and 131 Temp1 is an Intel-type thermal diode which requires the following formula to
|
H A D | w83781d.rst | 141 beta value in the sensor files. '1' is the PII/Celeron diode, '2' is the 197 - Problems with diode/thermistor settings (supported?) 260 > programmable to be either thermistor or Pentium II diode inputs. 261 > How do I program them for diode inputs? I can't find any register 262 > to program these to be diode inputs. 270 diode 1 1 1 276 PII thermal diode 1 1 1 277 2N3904 diode 0 0 0
|
H A D | lm83.rst | 31 a stripped down version of the LM83 that only supports one external diode. 34 in that the later can only sense the temperature of one external diode.
|
H A D | emc2103.rst | 35 as temp3 and temp4. If only one diode is attached to this channel, temp4
|
/openbmc/linux/drivers/iio/temperature/ |
H A D | ltc2983.c | 606 struct ltc2983_diode *diode = to_diode(sensor); in ltc2983_diode_assign_chan() local 609 chan_val = LTC2983_DIODE_CFG(diode->sensor_config); in ltc2983_diode_assign_chan() 1066 struct ltc2983_diode *diode; in ltc2983_diode_new() local 1070 diode = devm_kzalloc(&st->spi->dev, sizeof(*diode), GFP_KERNEL); in ltc2983_diode_new() 1071 if (!diode) in ltc2983_diode_new() 1075 diode->sensor_config = LTC2983_DIODE_SGL(1); in ltc2983_diode_new() 1100 diode->excitation_current = 0x00; in ltc2983_diode_new() 1103 diode->excitation_current = 0x01; in ltc2983_diode_new() 1106 diode->excitation_current = 0x02; in ltc2983_diode_new() 1109 diode->excitation_current = 0x03; in ltc2983_diode_new() [all …]
|
/openbmc/linux/Documentation/devicetree/bindings/hwmon/ |
H A D | nuvoton,nct7802.yaml | 61 - thermal-diode 137 temperature-mode = "thermal-diode";
|
/openbmc/linux/Documentation/devicetree/bindings/iio/temperature/ |
H A D | adi,ltc2983.yaml | 147 "^diode@": 166 resistance between the device and the diode. 171 Whether to use a running average of the diode temperature 172 reading to reduce the noise when the diode is used as a cold 179 Magnitude of the 1l excitation current applied to the diode. 502 diode5: diode@5 {
|
/openbmc/openbmc/meta-openembedded/meta-oe/recipes-extended/wipe/ |
H A D | wipe_0.24.bb | 8 HOMEPAGE = "http://lambda-diode.com/software/wipe/"
|
/openbmc/linux/Documentation/devicetree/bindings/regulator/ |
H A D | richtek,rtmv20-regulator.yaml | 7 title: Richtek RTMV20 laser diode regulator 14 It is used to drive laser diode. There're two signals for chip controls
|
/openbmc/linux/drivers/rtc/ |
H A D | rtc-abx80x.c | 571 const char *diode; in abx80x_dt_trickle_cfg() local 576 ret = of_property_read_string(np, "abracon,tc-diode", &diode); in abx80x_dt_trickle_cfg() 580 if (!strcmp(diode, "standard")) { in abx80x_dt_trickle_cfg() 582 } else if (!strcmp(diode, "schottky")) { in abx80x_dt_trickle_cfg() 585 dev_dbg(&client->dev, "Invalid tc-diode value: %s\n", diode); in abx80x_dt_trickle_cfg()
|
H A D | rtc-ds1307.c | 520 static u8 do_trickle_setup_ds1339(struct ds1307 *ds1307, u32 ohms, bool diode) in do_trickle_setup_ds1339() argument 522 u8 setup = (diode) ? DS1307_TRICKLE_CHARGER_DIODE : in do_trickle_setup_ds1339() 545 static u8 do_trickle_setup_rx8130(struct ds1307 *ds1307, u32 ohms, bool diode) in do_trickle_setup_rx8130() argument 549 if (diode) in do_trickle_setup_rx8130() 1283 bool diode = chip->charge_default; in ds1307_trickle_init() local 1299 diode = false; in ds1307_trickle_init() 1302 diode = true; in ds1307_trickle_init() 1311 diode = false; in ds1307_trickle_init() 1314 return chip->do_trickle_setup(ds1307, ohms, diode); in ds1307_trickle_init()
|