1 #pragma once 2 /**************************************************************** 3 * READ THIS WARNING FIRST 4 * This is an auto-generated header which contains definitions 5 * for Redfish DMTF defined messages. 6 * DO NOT modify this registry outside of running the 7 * parse_registries.py script. The definitions contained within 8 * this file are owned by DMTF. Any modifications to these files 9 * should be first pushed to the relevant registry in the DMTF 10 * github organization. 11 ***************************************************************/ 12 #include "registries.hpp" 13 14 #include <array> 15 16 // clang-format off 17 18 namespace redfish::registries::storage_device 19 { 20 const Header header = { 21 "Copyright 2020-2023 DMTF. All rights reserved.", 22 "#MessageRegistry.v1_6_2.MessageRegistry", 23 "StorageDevice.1.2.1", 24 "Storage Device Message Registry", 25 "en", 26 "This registry defines the messages for storage devices.", 27 "StorageDevice", 28 "1.2.1", 29 "DMTF", 30 }; 31 constexpr const char* url = 32 "https://redfish.dmtf.org/registries/StorageDevice.1.2.1.json"; 33 34 constexpr std::array registry = 35 { 36 MessageEntry{ 37 "BatteryCharging", 38 { 39 "A battery charging condition was detected.", 40 "A charging condition for the battery located in '%1' was detected.", 41 "Warning", 42 1, 43 { 44 "string", 45 }, 46 "None. There may be reduced performance and features while the battery is charging.", 47 }}, 48 MessageEntry{ 49 "BatteryFailure", 50 { 51 "A battery failure condition was detected.", 52 "A failure condition for the battery located in '%1' was detected.", 53 "Critical", 54 1, 55 { 56 "string", 57 }, 58 "Ensure all cables are properly and securely connected. Replace the failed battery.", 59 }}, 60 MessageEntry{ 61 "BatteryMissing", 62 { 63 "A battery missing condition was detected.", 64 "The battery located in '%1' is missing.", 65 "Critical", 66 1, 67 { 68 "string", 69 }, 70 "Attach the battery. Ensure all cables are properly and securely connected.", 71 }}, 72 MessageEntry{ 73 "BatteryOK", 74 { 75 "The health of a battery has changed to OK.", 76 "The health of the battery located in '%1' has changed to OK.", 77 "OK", 78 1, 79 { 80 "string", 81 }, 82 "None.", 83 }}, 84 MessageEntry{ 85 "ControllerDegraded", 86 { 87 "A storage controller degraded condition was detected.", 88 "A degraded condition for the storage controller located in '%1' was detected due to reason '%2'.", 89 "Warning", 90 2, 91 { 92 "string", 93 "string", 94 }, 95 "Reseat the storage controller in the PCI slot. Update the controller to the latest firmware version. If the issue persists, replace the controller.", 96 }}, 97 MessageEntry{ 98 "ControllerFailure", 99 { 100 "A storage controller failure was detected.", 101 "A failure condition for the storage controller located in '%1' was detected.", 102 "Critical", 103 1, 104 { 105 "string", 106 }, 107 "Reseat the storage controller in the PCI slot. Update the controller to the latest firmware version. If the issue persists, replace the controller.", 108 }}, 109 MessageEntry{ 110 "ControllerOK", 111 { 112 "The storage controller health has changed to OK.", 113 "The health of the storage controller located in '%1' has changed to OK.", 114 "OK", 115 1, 116 { 117 "string", 118 }, 119 "None.", 120 }}, 121 MessageEntry{ 122 "ControllerPasswordAccepted", 123 { 124 "The storage controller password was entered.", 125 "A password was entered for the storage controller located in '%1'.", 126 "OK", 127 1, 128 { 129 "string", 130 }, 131 "None.", 132 }}, 133 MessageEntry{ 134 "ControllerPasswordRequired", 135 { 136 "The storage controller requires a password.", 137 "The storage controller located in '%1' requires a password.", 138 "Critical", 139 1, 140 { 141 "string", 142 }, 143 "Enter the controller password.", 144 }}, 145 MessageEntry{ 146 "ControllerPortDegraded", 147 { 148 "A controller port degraded condition was detected.", 149 "A degraded condition for the controller port located in '%1' was detected due to reason '%2'.", 150 "Warning", 151 2, 152 { 153 "string", 154 "string", 155 }, 156 "Ensure all cables are properly and securely connected. Replace faulty cables.", 157 }}, 158 MessageEntry{ 159 "ControllerPortFailure", 160 { 161 "A controller port failure condition was detected.", 162 "A failure condition for the controller port located in '%1' was detected.", 163 "Critical", 164 1, 165 { 166 "string", 167 }, 168 "Ensure all cables are properly and securely connected. Replace faulty cables.", 169 }}, 170 MessageEntry{ 171 "ControllerPortOK", 172 { 173 "The health of a controller port has changed to OK.", 174 "The health of the controller port located in '%1' has changed to OK.", 175 "OK", 176 1, 177 { 178 "string", 179 }, 180 "None.", 181 }}, 182 MessageEntry{ 183 "ControllerPreviousError", 184 { 185 "A storage controller error was detected prior to reboot.", 186 "A previous error condition for the storage controller located in '%1' was detected due to '%2'.", 187 "Warning", 188 2, 189 { 190 "string", 191 "string", 192 }, 193 "Update the controller to the latest firmware version. If the issue persists, replace the controller.", 194 }}, 195 MessageEntry{ 196 "DriveFailure", 197 { 198 "A drive failure condition was detected.", 199 "A failure condition for the drive located in '%1' was detected.", 200 "Critical", 201 1, 202 { 203 "string", 204 }, 205 "Ensure all cables are properly and securely connected. Ensure all drives are fully seated. Replace the defective cables, drive, or both.", 206 }}, 207 MessageEntry{ 208 "DriveFailureCleared", 209 { 210 "A previously detected failure condition on a drive was cleared.", 211 "A failure condition for the drive located in '%1' was cleared.", 212 "OK", 213 1, 214 { 215 "string", 216 }, 217 "None.", 218 }}, 219 MessageEntry{ 220 "DriveInserted", 221 { 222 "A drive was inserted.", 223 "The drive located in '%1' was inserted.", 224 "OK", 225 1, 226 { 227 "string", 228 }, 229 "If the drive is not properly displayed, attempt to refresh the cached data.", 230 }}, 231 MessageEntry{ 232 "DriveMissing", 233 { 234 "A drive missing condition was detected.", 235 "A missing condition for the drive located in '%1' was detected.", 236 "Critical", 237 1, 238 { 239 "string", 240 }, 241 "Ensure all cables are properly and securely connected. Ensure all drives are fully seated. Replace the defective cables, drive, or both. Delete the volume if it is no longer needed.", 242 }}, 243 MessageEntry{ 244 "DriveMissingCleared", 245 { 246 "A previous drive missing condition was cleared.", 247 "A missing condition for the drive located in '%1' was cleared.", 248 "OK", 249 1, 250 { 251 "string", 252 }, 253 "None.", 254 }}, 255 MessageEntry{ 256 "DriveOK", 257 { 258 "The health of a drive has changed to OK.", 259 "The health of the drive located in '%1' has changed to OK.", 260 "OK", 261 1, 262 { 263 "string", 264 }, 265 "None.", 266 }}, 267 MessageEntry{ 268 "DriveOffline", 269 { 270 "A drive offline condition was detected.", 271 "An offline condition for the drive located in '%1' was detected.", 272 "Critical", 273 1, 274 { 275 "string", 276 }, 277 "If the drive is unconfigured or needs an import, configure the drive. If the drive operation is in progress, wait for the operation to complete. If the drive is not supported, replace it.", 278 }}, 279 MessageEntry{ 280 "DriveOfflineCleared", 281 { 282 "A drive offline condition was cleared.", 283 "An offline condition for the drive located in '%1' was cleared.", 284 "OK", 285 1, 286 { 287 "string", 288 }, 289 "None.", 290 }}, 291 MessageEntry{ 292 "DrivePredictiveFailure", 293 { 294 "A predictive drive failure condition was detected.", 295 "A predictive failure condition for the drive located in '%1' was detected.", 296 "Warning", 297 1, 298 { 299 "string", 300 }, 301 "If this drive is not part of a fault-tolerant volume, first back up all data, then replace the drive and restore all data afterward. If this drive is part of a fault-tolerant volume, replace this drive as soon as possible as long as the volume health is OK.", 302 }}, 303 MessageEntry{ 304 "DrivePredictiveFailureCleared", 305 { 306 "A previously detected predictive failure condition on a drive was cleared.", 307 "A predictive failure condition for the drive located in '%1' was cleared.", 308 "OK", 309 1, 310 { 311 "string", 312 }, 313 "None.", 314 }}, 315 MessageEntry{ 316 "DriveRemoved", 317 { 318 "A drive was removed.", 319 "The drive located in '%1' was removed.", 320 "Critical", 321 1, 322 { 323 "string", 324 }, 325 "If the drive is still displayed, attempt to refresh the cached data.", 326 }}, 327 MessageEntry{ 328 "VolumeDegraded", 329 { 330 "The storage controller has detected a degraded volume condition.", 331 "The volume '%1' attached to the storage controller located in '%2' is degraded.", 332 "Warning", 333 2, 334 { 335 "string", 336 "string", 337 }, 338 "Ensure all cables are properly and securely connected. Replace failed drives.", 339 }}, 340 MessageEntry{ 341 "VolumeFailure", 342 { 343 "The storage controller has detected a failed volume condition.", 344 "The volume '%1' attached to the storage controller located in '%2' has failed.", 345 "Critical", 346 2, 347 { 348 "string", 349 "string", 350 }, 351 "Ensure all cables are properly and securely connected. Ensure all drives are fully seated and operational.", 352 }}, 353 MessageEntry{ 354 "VolumeOK", 355 { 356 "A volume health has changed to OK.", 357 "The health of volume '%1' that is attached to the storage controller located in '%2' has changed to OK.", 358 "OK", 359 2, 360 { 361 "string", 362 "string", 363 }, 364 "None.", 365 }}, 366 MessageEntry{ 367 "VolumeOffine", 368 { 369 "The storage controller has detected an offline volume condition.", 370 "The volume '%1' attached to the storage controller located in '%2' is offline.", 371 "Critical", 372 2, 373 { 374 "string", 375 "string", 376 }, 377 "Use storage software to enable, repair, or import the volume. You may also delete or move volume back to the original controller.", 378 }}, 379 MessageEntry{ 380 "VolumeOffline", 381 { 382 "The storage controller has detected an offline volume condition.", 383 "The volume '%1' attached to the storage controller located in '%2' is offline.", 384 "Critical", 385 2, 386 { 387 "string", 388 "string", 389 }, 390 "Use storage software to enable, repair, or import the volume. You may also delete or move volume back to the original controller.", 391 }}, 392 MessageEntry{ 393 "VolumeOfflineCleared", 394 { 395 "The storage controller has detected an online volume condition.", 396 "The volume '%1' attached to the storage controller located in '%2' is online.", 397 "OK", 398 2, 399 { 400 "string", 401 "string", 402 }, 403 "None.", 404 }}, 405 MessageEntry{ 406 "WriteCacheDataLoss", 407 { 408 "The write cache is reporting loss of data in posted-writes memory.", 409 "The write cache on the storage controller located in '%1' has data loss.", 410 "Critical", 411 1, 412 { 413 "string", 414 }, 415 "Check the controller resource properties to determine the cause of the write cache data loss.", 416 }}, 417 MessageEntry{ 418 "WriteCacheDegraded", 419 { 420 "The write cache state is degraded.", 421 "The write cache state on the storage controller located in '%1' is degraded.", 422 "Critical", 423 1, 424 { 425 "string", 426 }, 427 "Check the controller to determine the cause of write cache degraded state, such as a missing battery or hardware failure.", 428 }}, 429 MessageEntry{ 430 "WriteCacheProtected", 431 { 432 "A storage controller write cache state is in protected mode.", 433 "The write cache state on the storage controller located in '%1' is in protected mode.", 434 "OK", 435 1, 436 { 437 "string", 438 }, 439 "None.", 440 }}, 441 MessageEntry{ 442 "WriteCacheTemporarilyDegraded", 443 { 444 "The write cache state is temporarily degraded.", 445 "The write cache state on the storage controller located in '%1' is temporarily degraded.", 446 "Warning", 447 1, 448 { 449 "string", 450 }, 451 "Check the controller to determine the cause of write cache temporarily degraded state, such as a battery is charging or a data recovery rebuild operation is pending.", 452 }}, 453 454 }; 455 456 enum class Index 457 { 458 batteryCharging = 0, 459 batteryFailure = 1, 460 batteryMissing = 2, 461 batteryOK = 3, 462 controllerDegraded = 4, 463 controllerFailure = 5, 464 controllerOK = 6, 465 controllerPasswordAccepted = 7, 466 controllerPasswordRequired = 8, 467 controllerPortDegraded = 9, 468 controllerPortFailure = 10, 469 controllerPortOK = 11, 470 controllerPreviousError = 12, 471 driveFailure = 13, 472 driveFailureCleared = 14, 473 driveInserted = 15, 474 driveMissing = 16, 475 driveMissingCleared = 17, 476 driveOK = 18, 477 driveOffline = 19, 478 driveOfflineCleared = 20, 479 drivePredictiveFailure = 21, 480 drivePredictiveFailureCleared = 22, 481 driveRemoved = 23, 482 volumeDegraded = 24, 483 volumeFailure = 25, 484 volumeOK = 26, 485 volumeOffine = 27, 486 volumeOffline = 28, 487 volumeOfflineCleared = 29, 488 writeCacheDataLoss = 30, 489 writeCacheDegraded = 31, 490 writeCacheProtected = 32, 491 writeCacheTemporarilyDegraded = 33, 492 }; 493 } // namespace redfish::registries::storage_device 494